Olakunle Olabode

Mr. Olakunle Olabode

Bells University of Technology, Ota, Ogun State
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
Daniel AkinyeleDaniel Akinyele
Daniel Akinyele
Abraham AmoleAbraham Amole
Abraham Amole
Olakunle OlabodeOlakunle Olabode
Olakunle Olabode
AOAyobami Olusesi
Ayobami Olusesi
TATitus Ajewole
Titus Ajewole
Energy systems modelling and design are a critical aspect of planning and development among researchers, electricity planners, infrastructure developers, utilities, decision-makers, and other relevant stakeholders. However, to achieve a sustainable energy supply, the energy planning approach needs to integrate some key dimensions. Importantly, these dimensions are necessary to guide the simulation and evaluation. It is against this backdrop that this paper focuses on the simulation and analysis approaches for sustainable planning, design, and development of microgrids based on clean energy resources. The paper first provides a comprehensive review of the existing simulation tools and approaches used for designing energy generation technologies. It then discusses and compares the traditional strategies and the emerging trends in energy systems simulation based on the software employed, the type of problem to be solved, input parameters provided, and the expected output. The paper introduces a practical simulation framework for sustainable energy planning, which is based on the social-technical-economic-environmental-policy (STEEP) model. The STEEP represents a holistic sustainability model that considers the key energy systems planning dimensions compared to the traditional techno-economic model used in several existing simulation tools and analyses. The paper provides insights into data-driven analysis and energy modelling software development applications.


23 December 2019 in Energy Storage
Verified
Journal Article
Open access
PDF file
Olakunle OlabodeOlakunle Olabode
Olakunle Olabode
IOIgnatius K. Okakwu
Ignatius K. Okakwu
AAAkintunde Alayande
Akintunde Alayande
TATitus O. Ajewole
Titus O. Ajewole
Reactive power compensation on radial distribution systems is a challenging issue. Electric power distribution systems are being bedeviled by high active power loss and severe voltage violation especially on the buses that are far from distribution substations. This article presents a two‐stage approach for sizing shunt capacitors and identifying the locations where their placement would be most beneficial within radial distribution systems. A multiobjective function capturing real power loss minimization and bus voltage profile enhancement was formulated and weighted approach was engaged to transform the function into single objective one. While backward forward sweep approach was used for the load flow analysis, loss sensitivity factor was employed to predetermine suitable sites for capacitor installation, with the optimal sites and sizes determined using cuckoo search algorithm. This approach was implemented on IEEE 15‐bus and Yale 17‐bus/11 kV feeder. Results obtained using the method was thereafter compared with those obtained through other methods as obtained from literature and the comparison shows that cuckoo search algorithm outsmarts others. Significant reduction in real power loss, coupled with appreciable enhancement in voltage profile, is achieved on the Yale 17‐bus/11 kV feeder. The approach is therefore viable for addressing reactive power compensation problems confronting practical radial distribution systems.

1 July 2020 in Scientific African
Verified
Journal Article
Open access
TATitus O. Ajewole
Titus O. Ajewole
Olakunle OlabodeOlakunle Olabode
Olakunle Olabode
OBOlufisayo S. Babalola
Olufisayo S. Babalola
MOMichael O. Omoigui
Michael O. Omoigui

1 March 2020
Verified
Conference Paper
Closed access
Olakunle OlabodeOlakunle Olabode
Olakunle Olabode
Abraham AmoleAbraham Amole
Abraham Amole
TATitus Ajewole
Titus Ajewole
IOIgnatius Okakwu
Ignatius Okakwu
Electrical energy enriches today’s world and so the forecast of its consumption aids energy industries, governments, as well as investors in making informed decisions at any point in time. It is on this background that this paper engaged regression analysis techniques to forecast on medium-term basis the electric power consumption within the region of Abeokuta in Ogun State of Nigeria. Three different regression techniques: linear, compound-growth and quadratic; were employed to forecast the energy demand based on previous load consumption of the study area. The performance evaluation metrics employed to measure the accuracy of the forecast are the Mean Average Percentage Error (MAPE) and the Root Mean Square Error (RMSE). Of the three techniques, linear regression recorded the least values of MAPE and RMSE. Therefore, with the employment of the linear regression technique, the load demand for July to December in 2018 was forecasted and the percentage load growth achieved for each of the months. The results obtained from this analysis could assist the management of the Regional Headquarters of the Ibadan Electricity Distribution Company on the need to make adequate planning that would facilitate efficient management of energy supply within the region.

1 January 2024 in Iranica Journal of Energy and Environment
Verified
Journal Article
Open access
PDF file
Olakunle OlabodeOlakunle Olabode
Olakunle Olabode
IOI. K. Okakwu
I. K. Okakwu
DAD. O. Akinyele
D. O. Akinyele
TAT. O. Ajewole
T. O. Ajewole
SOS. Oyelami
S. Oyelami
OOO. V. Olisa
O. V. Olisa
The impact of solar radiation and ambient temperature on solar PV energy yield and its corresponding economic implication was investigated. The electrical load assessment was done by physical inspection through periodic visits to study location. Five different scenarios were investigated for two locations - Ogun and Bayelsa States: Case I considers the PV performance based on the locations’ historical solar radiation and temperature data, Case II considers 30 % increase in the solar radiation data while the ambient temperature data remains fixed, Case III focuses on when solar radiation data is decreased by 30 % while the ambient temperature data remains constant, Case IV considers the solar radiation data remains constant while the temperature values are increased by 30 %, and Case V examined the same solar radiation values with temperature data values being decreased by 30 %. The HOMER pro was used as the implementation tool, Electrical energy yield, Unmet electric load, Net present cost, Levelized cost, and Operating cost for Cases I, II, III, IV, and V in Ota, Ogun State were as follows: 28,659 kWh/y, 4.71kWh/y, $13,537, $0.166, 271.43kWh/y; 37,260 kWh/y, 1.63kWh/y, $12,417, $0.152, 290.43kWh/y; 20,058kWh/y, 3.22kWh/y, $15,663, $0.192, 293.14kWh/y; 28,659kWh/y, 4.71kWh/y, $13,537, $0.166, 271.43kWh/y; and 28,659kWh/y, 4.61kWh/y, $13,437, $0.156, 261.43kWh/y, respectively while similar trend was observed for Otuasega in Bayelsa State. The results of the analysis showed that the optimal performance of the PV module occurred at a higher solar radiation and a lower ambient temperature.