Chao Xu

Dr. Chao Xu

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
SYsishen yuan
sishen yuan
Chao XuChao Xu
Chao Xu
BCBeilei Cui
Beilei Cui
TZTinghua Zhang
Tinghua Zhang
BLBaijia Liang
Baijia Liang
Hongliang RenHongliang Ren
Hongliang Ren
Intraluminal epithelial abnormalities, potential precursors to significant conditions like cancer, necessitate early detection for improved prognosis. We present a motor-free telerobotic optical coherence tomography (OCT) endoscope that offers high-resolution intraluminal imaging and overcomes the limitations of traditional systems in navigating curved lumens. This system incorporates a compact magnetic rotor with a rotatable diametrically magnetized cylinder permanent magnet (RDPM) and a reflector, effectively mitigating thermal and electrical risks by utilizing an external magnetic field to maintain temperature increases below 0.5 °C and generated voltage under 0.02 mV. Additionally, a learning-based method corrects imaging distortions resulting from nonuniform rotational speeds. Demonstrating superior maneuverability, the device achieves steerable angles up to 110° and operates effectively in vivo, providing distortion-free 3D programmable imaging in mouse colons. This advancement represents a significant step towards guidewire-independent endomicroscopy, enhancing both safety and potential patient outcomes.

30 August 2024 in Science Advances
Verified
Journal Article
Open access
TZTinghua Zhang
Tinghua Zhang
SYsishen yuan
sishen yuan
Chao XuChao Xu
Chao Xu
PLPeng Liu
Peng Liu
HCHing-Chiu Chang
Hing-Chiu Chang
Wu YuanWu Yuan
Wu Yuan
The complex anatomy of internal luminal organs, like bronchioles, poses challenges for endoscopic optical coherence tomography (OCT). These challenges include limited steerability for targeted imaging and nonuniform rotation distortion (NURD) with proximal scanning. Using rotary micromotors for distal scanning could address NURD but raises concerns about electrical safety and costs. We present pneumaOCT, the first pneumatic OCT endoscope, comprising a steerable catheter with a soft pneumatic actuator and an imaging probe with a miniature pneumatic turbine. With a diameter of 2.8 mm, pneumaOCT allows for a bending angle of up to 237°, facilitating navigation through narrow turns. The pneumatic turbine enables adjustable imaging speeds from 51 to 446 revolutions per second. We demonstrate the pneumaOCT in vivo imaging of mouse esophagus and colon, as well as targeted and distortion-free imaging of peripheral bronchioles in a bronchial phantom and a porcine lung. This advancement substantially improves endoscopic OCT for navigational imaging in curved and narrow lumens.

2 January 2024 in Communications Engineering
Verified
Journal Article
Open access
PDF file
Chao XuChao Xu
Chao Xu
XGXin Guan
Xin Guan
SASyeda Aimen Abbasi
Syeda Aimen Abbasi
NXNeng Xia
Neng Xia
TNTo Ngai
To Ngai
Wu YuanWu Yuan
Wu Yuan
Endoscopic optical coherence tomography (OCT) is a valuable tool for providing diagnostic images of internal organs and guiding interventions in real time. Miniaturized OCT endoscopes are essential for imaging small and convoluted luminal organs while minimizing invasiveness. However, current methods for fabricating miniature fiber probes have limited ability to correct optical aberrations, leading to suboptimal imaging performance. Here we introduce a liquid shaping technique for the rapid and scalable fabrication of ultrathin and high-performance OCT microendoscopes suitable for minimally invasive clinical applications. This technique enables the flexible customization of freeform microlenses with sub-nanometer optical surface roughness by regulating the minimum energy state of curable optical liquid on a wettability-modified substrate and precisely controlling the liquid volume and physical boundary on a substrate. Using this technique, we simultaneously fabricated 800-nm OCT microendoscopes with a diameter of approximately 0.6 mm and evaluated their ultrahigh-resolution imaging performance in the esophagus of rats and the aorta and brain of mice.

2 August 2023 in Photonics
Verified
Journal Article
Open access
PDF file
JWJiarui WANG
Jiarui WANG
Chao XuChao Xu
Chao Xu
SZShaodi Zhu
Shaodi Zhu
DCDefu Chen
Defu Chen
HQHaixia Qiu
Haixia Qiu
Wu YuanWu Yuan
Wu Yuan
Compared with optical coherence tomography (OCT) in the near-infrared domain, the visible-light OCT (vis-OCT) system affords a higher axial resolution for discerning subtle pathological changes associated with early diseases. However, the significant material dispersion at the visible-light range leads to a severe problem for dispersion management in vis-OCT systems, which results in a compromised axial resolution. While dispersion compensators (such as prism pairs) are commonly used, a digital method is still highly desirable and has been widely used to compensate for the residual dispersion imbalance between the reference and sample arms in an OCT system. In this paper, we develop a generic approach to effectively compensate for the system dispersion, especially the higher-order dispersion in the vis-OCT system, by using a single arbitrary measurement of the mirror-reflection (SAMMR) method and its resulting phase information. Compared with the previous methods, including the method based on the Taylor series iterative fitting and differential method, the proposed method does not need to extract the dispersion coefficients or use the metric functions and affords a better performance for axial resolution and the signal-to-noise ratio in vis-OCT systems. Its effectiveness is further validated in an OCT system operating in the near-infrared domain.


1 November 2024 in APL Photonics
Verified
Journal Article
Open access
PDF file
Chao XuChao Xu
Chao Xu
TZTinghua Zhang
Tinghua Zhang
SASyeda Aimen Abbasi
Syeda Aimen Abbasi
PLPeng Liu
Peng Liu
BYBryan P. Yan
Bryan P. Yan
Wu YuanWu Yuan
Wu Yuan
Deep-brain neuroimaging, a task that demands high-resolution imaging techniques for visualizing intricate brain structures, assessing deep-seated disease histopathology, and offering real-time intervention guidance, is challenged by the resolution-depth trade-off of current methods. We propose an optical coherence tomography (OCT) endomicroscopy device for high-resolution in vivo imaging of deep brain microstructures and histopathology. A unique liquid shaping technique enables the direct fabrication of a microlens on the fiber tip of the imaging probe, optimizing imaging performance parameters, such as longitudinal focal shift, focused spot size, and working distance. In addition, a broadband visible-light source enhances axial resolution and OCT imaging contrast. As a result, the first monolithic visible-light OCT (vis-OCT) endomicroscope, with a submillimeter outer diameter (∼0.4 mm), is presented, achieving an ultrahigh resolution of 1.4 μm axial × 4.5 μm transverse in air. This compact probe allows minimally invasive in vivo deep-brain imaging in mice at a depth of 7.2 mm. Key regions in the mouse deep brain, such as the isocortex, corpus callosum, and caudate putamen, were successfully identified using our vis-OCT endomicroscope. In addition, we examined the myeloarchitectures and cytoarchitectures in the isocortex. Our findings demonstrate that the vis-OCT endomicroscope offers enhanced visualization of myelinated axon fibers and nerve fiber bundles compared to its 800 nm counterpart. This vis-OCT endomicroscope, overcoming resolution and imaging depth limitations of conventional methods, offers a novel tool for minimally invasive, ultrahigh-resolution in vivo deep brain neuroimaging.