Olivier Rukundo

Dr. Olivier Rukundo

University Clinic of Dentistry, Medical University of Vienna, Vienna, Wien, Austria
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in International Journal of Advanced Computer Science and Applications
Verified
Journal Article
Open access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo
CHCao Hanqiang
Cao Hanqiang
This paper presents the nearest neighbor value (NNV) algorithm for high resolution (H.R.) image interpolation. The difference between the proposed algorithm and conventional nearest neighbor algorithm is that the concept applied, to estimate the missing pixel value, is guided by the nearest value rather than the distance. In other words, the proposed concept selects one pixel, among four directly surrounding the empty location, whose value is almost equal to the value generated by the conventional bilinear interpolation algorithm. The proposed method demonstrated higher performances in terms of H.R. when compared to the conventional interpolation algorithms mentioned.

16 February 2023 in Electronics
Verified
Journal Article
Open access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo
In this work, the best size for late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) images in the training dataset was determined to optimize deep learning training outcomes. Non-extra pixel and extra pixel interpolation algorithms were used to determine the new size of the LGE-MRI images. A novel strategy was introduced to handle interpolation masks and remove extra class labels in interpolated ground truth (GT) segmentation masks. The expectation maximization, weighted intensity, a priori information (EWA) algorithm was used for the quantification of myocardial infarction (MI) in automatically segmented LGE-MRI images. Arbitrary threshold, comparison of the sums, and sums of differences are methods used to estimate the relationship between semi-automatic or manual and fully automated quantification of myocardial infarction (MI) results. The relationship between semi-automatic and fully automated quantification of MI results was found to be closer in the case of bigger LGE MRI images (55.5% closer to manual results) than in the case of smaller LGE MRI images (22.2% closer to manual results).

8 March 2021 in International Journal of Computational Methods
Verified
Journal Article
Closed access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo

31 October 2017 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo
MPMarius Pedersen
Marius Pedersen
ØHØistein Hovde
Øistein Hovde
This paper proposes an advanced method for contrast enhancement of capsule endoscopic images, with the main objective to obtain sufficient information about the vessels and structures in more distant (or darker) parts of capsule endoscopic images. The proposed method (PM) combines two algorithms for the enhancement of darker and brighter areas of capsule endoscopic images, respectively. The half-unit weighted-bilinear algorithm (HWB) proposed in our previous work is used to enhance darker areas according to the darker map content of its HSV’s component V. Enhancement of brighter areas is achieved thanks to the novel threshold weighted-bilinear algorithm (TWB) developed to avoid overexposure and enlargement of specular highlight spots while preserving the hue, in such areas. The TWB performs enhancement operations following a gradual increment of the brightness of the brighter map content of its HSV’s component V. In other words, the TWB decreases its averaged weights as the intensity content of the component V increases. Extensive experimental demonstrations were conducted, and, based on evaluation of the reference and PM enhanced images, a gastroenterologist (Ø.H.) concluded that the PM enhanced images were the best ones based on the information about the vessels, contrast in the images, and the view or visibility of the structures in more distant parts of the capsule endoscopy images.

5 October 2015 in Computer and Information Science
Verified
Journal Article
Open access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo
In this study, the standard IEEE 754–2008 and modulo-based floor functions for rounding non-integers have been presented. Their effects on the accuracy of the bilinear interpolation algorithm have been demonstrated. The improved-floor uses the modulo operator in an effort to make each non-integer addend an integer when the remainder between the multiplicative inverse of the fractional factor and the numerator is greater than zero. The experiments demonstrated relatively positive effects with the improved-floor function and the alternativeness to the standard round function.

1 April 2016 in SpringerPlus
Verified
Journal Article
Open access
PDF file
Olivier RukundoOlivier Rukundo
Olivier Rukundo
HCHanqiang Cao
Hanqiang Cao
This paper presents an advance on image interpolation based on ant colony algorithm (AACA) for high resolution image scaling. The difference between the proposed algorithm and the previously proposed optimization of bilinear interpolation based on ant colony algorithm (OBACA) is that AACA uses global weighting, whereas OBACA uses local weighting scheme. The strength of the proposed global weighting of AACA algorithm depends on employing solely the pheromone matrix information present on any group of four adjacent pixels to decide which case deserves a maximum global weight value or not. Experimental results are further provided to show the higher performance of the proposed AACA algorithm with reference to the algorithms mentioned in this paper.