Osvaldo Magro-Filho

Prof. Dr. Osvaldo Magro-Filho


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2024 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
MSMaísa Pereira Silva
Maísa Pereira Silva
Henrique HadadHenrique Hadad
Henrique Hadad
Laís Kawamata de JesusLaís Kawamata de Jesus
Laís Kawamata de Jesus
MOMaria Eduarda de Freitas Santana Oliveira
Maria Eduarda de Freitas Santana Oliveira
JAJuliano Milanezi De Almeida
Juliano Milanezi De Almeida
FSFrancisley Ávila Souza
Francisley Ávila Souza

4 February 2025 in Life
Verified
Journal Article
Open access
PDF file
BCBeethoven Estevão Costa
Beethoven Estevão Costa
RYRenato Yassutaka Faria Yaedu
Renato Yassutaka Faria Yaedu
MSMaísa Pereira Silva
Maísa Pereira Silva
AFAndré. da Silva Fabris
André. da Silva Fabris
MGMICHELE GARCIA-USÓ
MICHELE GARCIA-USÓ
SSSimone Soares
Simone Soares
The increasing use of cone beam computed tomography (CBCT) has led to a growing demand for DICOM software that enables the assessment and measurement of craniofacial structures. This study aimed to compare the airway volume and the minimum axial area in patients with cleft lip and palate using five different imaging software programs: Dolphin3D, InVivo Dental, ITK Snap, InVesalius, and NemoFAB. Initially, 100 CBCT scans were selected by an examiner, and their corresponding DICOM files were collected. The oropharyngeal segments were delineated following the manufacturer’s guidelines, using two different segmentation techniques: interactive and fixed threshold. The results were analyzed using the Friedman test and Wilcoxon post hoc test, with a 5% significance level for all statistical tests. The findings for both the minimum axial area and total volume revealed that the median values across the software groups were higher than expected, and significant differences were observed when comparing the groups (p < 0.001). All five software programs showed notable differences in their outputs. Specifically, a statistically significant difference in volume was found across all groups, except between InVivo and ITK-Snap. It is recommended that pre- and post-treatment comparisons be performed using the same software for consistency.

Verified
Journal Article
Open access
PDF file
GGGustavo Augusto Grossi-Oliveira
Gustavo Augusto Grossi-Oliveira
EDEDUARDO DALLAZEN
EDUARDO DALLAZEN
TAThabet Asbi
Thabet Asbi
JFJoão Matheus Fonseca-Santos
João Matheus Fonseca-Santos
PRPaulo Domingos Ribeiro-Júnior
Paulo Domingos Ribeiro-Júnior
LFLeonardo Faverani
Leonardo Faverani
This study investigated the effect of platelet-rich fibrin (PRF) on bone healing around implants placed in elevated sinus cavities. Forty New Zealand albino rabbits were divided into eight groups, based on the time of sacrifice (14 or 40 days) and the material used: blood clot (control), hydroxyapatite (HA) from bovine bone, HA combined with PRF, and PRF alone. Each group consisted of five animals (n = 5). A histological analysis measured bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). The results showed significant increases in the BIC and BAFO values at 40 days compared to 14 days in most groups. At day 14, the HA+PRF group had higher BIC than the clot and the PRF alone groups. At 40 days, HA+PRF maintained the highest BIC across all groups (p < 0.05), though it did not show an advantage for BAFO. These findings indicate that combining HA with PRF promotes better osseointegration around implants placed immediately in maxillary sinus augmentation. Given the limited research on PRF’s biological impact, these results underscore the importance of evaluating PRF’s role in peri-implant healing and its potential benefits for clinical use in sinus augmentation.

9 December 2024 in Life
Verified
Journal Article
Open access
PDF file
MPMateus Diego Pavelski
Mateus Diego Pavelski
MPMaicon Douglas Pavelski
Maicon Douglas Pavelski
LOLuana Ferreira Oliveira
Luana Ferreira Oliveira
HSHélio Doyle Pereira da Silva
Hélio Doyle Pereira da Silva
LFLucio Frigo
Lucio Frigo
Osvaldo Magro-FilhoOsvaldo Magro-Filho
Osvaldo Magro-Filho
Low-level laser therapy (LLLT) is known for its biostimulant properties, which can reduce inflammation and promote tissue regeneration. The present study is randomized, blinded, and placebo-controlled and aims to investigate the role of LLLT in the postoperative recovery of facial fractures. Patients with fractures of the zygomatic bone are selected and divided into two groups: low-level laser and red placebo light. The patients are evaluated for bite force, pain, mouth opening, and paresthesia in the pre-operatory day, on days 1, 2, 7, and 14. The trismus data demonstrated better results in the laser with a significant difference in the periods 7 and 14 days, with p-values of 0.0442 and 0.026, respectively. Regarding the bite force analyzed, no statistically significant differences were observed. In the pain scale comparison, there was a difference between the PLACEBO group and the LASER group for day 1 (p = 0.011), day 2 (p = 0.001), 7 (p = 0.001), and 14 days (p = 0.010). In the evaluation of paresthesia, on days 7 and 14, there were better results in the LASER group with p = 0.012 and p = 0.001. The laser acted as a moderator of the healing process, having a considerable effect on the aspects of trismus, pain, postoperative paresthesia, and bite force.

7 July 2026 in Life
Verified
Journal Article
Open access
PDF file
EFEduardo Francisco de Souza Faco
Eduardo Francisco de Souza Faco
AAAndressa Paschoal Amoroso
Andressa Paschoal Amoroso
FPFlávia Priscila Pereira
Flávia Priscila Pereira
LOLuana Ferreira Oliveira
Luana Ferreira Oliveira
LSLeandro Lecio de lima Sousa
Leandro Lecio de lima Sousa
Osvaldo Magro-FilhoOsvaldo Magro-Filho
Osvaldo Magro-Filho
The growing demand for implant-supported rehabilitative prosthetic treatments has reinforced the need to optimize biomechanical performance, particularly regarding force distribution. This study aimed to evaluate the stress distribution generated by different configurations of full-arch implant-supported prostheses using three-dimensional finite element analysis. Two mandibular models were created using SolidWorks 2010 (SolidWorks Corp., Waltham, MA, USA) and Rhinoceros® 3D 4.0 (NURBS Modeling for Windows, USA). Each model represented a mandible restored with a full-arch fixed prosthesis supported by external hex implants (4.0 × 13.0 mm; Master, Conexão Sistemas de Prótese, São Paulo, Brazil) placed in the interforaminal region, differing only in implant angulation. Model 1 included four implants positioned perpendicular to the alveolar ridge, whereas Model 2 represented the All-on-Four configuration with distal implants tilted at 30°. The prosthesis was modeled in acrylic resin with a NiCr metal framework. The geometries were exported to FEMAP 11.0 for mesh generation. Axial loading of 300 N was applied bilaterally (75 N per tooth), and oblique loading of 150 N was applied unilaterally (75 N per tooth) on the first premolars and first molars. Obtained using NEiNastran® 9.2 showed that the tilted-implant model exhibited higher stress concentrations under both loading conditions. The All-on-Four configuration generated the highest stress levels, particularly around the distal implants. The null hypothesis of this study was that there would be no difference in stress distribution among full-arch implant-supported prostheses supported by straight implants and those rehabilitated according to the All-on-Four concept with tilted distal implants.

26 June 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
BCBeethoven Estevão Costa
Beethoven Estevão Costa
MSMaísa Pereira Silva
Maísa Pereira Silva
BLBianca Tiemi Uehara Lima
Bianca Tiemi Uehara Lima
GKGustavo Klein
Gustavo Klein
CJCelso Fernando Palmieri Junior
Celso Fernando Palmieri Junior
Osvaldo Magro-FilhoOsvaldo Magro-Filho
Osvaldo Magro-Filho
The selection of an appropriate fixation system is critical for maintaining postoperative stability after sagittal split ramus osteotomy (SSRO), especially in cases involving large mandibular advancements and counterclockwise rotation, where mechanical stresses may compromise treatment outcomes. This in vitro study evaluated the biomechanical stability of five fixation systems following sagittal split ramus osteotomy (SSRO) under two mandibular advancement conditions. Fifty polyurethane hemimandibles were allocated into two experimental groups: Group 1, submitted to 10-mm linear advancement, and Group 2, submitted to 10-mm advancement associated with 20° counterclockwise rotation. Each group was further divided into five subgroups according to the fixation design employed: (A) conventional straight plate, (B) angled plate, (C) sagittal plate, (D) 10-hole miniplate, and (E) two 4-hole miniplates. Biomechanical performance was assessed by compression testing using a universal testing machine. Complementary analyses were performed using strain gauges and digital image correlation. Group 1 in fixation B, C and D demonstrated higher biomechanical resistance than Group 2, however without significance difference. Among the evaluated configurations, subgroup E exhibited the highest resistance values in both experimental conditions. Statistically significant differences were observed among fixation systems within each group (p < 0.05). The fixation systems using two miniplates demonstrated superior biomechanical stability, particularly in mandibular advancements associated with counterclockwise rotational movements. These findings suggest that this fixation strategy may contribute to enhanced postoperative stability in orthognathic surgery involving large mandibular advancements and complex rotational movements.