In the design of whole-genome sequencing (WGS) studies, sequencing depth is a crucial parameter to define variant calling accuracy and study cost, with no standard recommendations having been established. We empirically evaluated the variant calling accuracy of the WGS pipeline using ultra-deep WGS data (approximately 410×). We randomly sampled sequence reads and constructed a series of simulation WGS datasets with a variety of gradual depths (n = 54; from 0.05× to 410×). Next, we evaluated the genotype concordances of the WGS data with those in the SNP microarray data or the WGS data using all the sequence reads. In addition, we assessed the accuracy of HLA allele genotyping using the WGS data with multiple software tools (PHLAT, HLA-VBseq, HLA-HD, and SNP2HLA). The WGS data with higher depths showed higher concordance rates, and >13.7× depth achieved as high as >99% of concordance. Comparisons with the WGS data using all the sequence reads showed that SNVs achieved >95% of concordance at 17.6× depth, whereas indels showed only 60% concordance. For the accuracy of HLA allele genotyping using the WGS data, 13.7× depth showed sufficient accuracy while performance heterogeneity among the software tools was observed (the highest concordance of 96.9% was observed with HLA-HD). Improvement in HLA genotyping accuracy by further increasing the depths was limited. These results suggest a medium degree of the WGS depth setting (approximately 15×) to achieve both accurate SNV calling and cost-effectiveness, whereas relatively higher depths are required for accurate indel calling.
1 August 2020 in Journal of Investigative Dermatology
A Diskhaler is a dry powder type of inhaler that utilizes a breath controlled drug delivery system. The inspiratory flow rate of the patient would have a significant influence on the effects of drugs administered by a Diskhaler. Thus, we investigated the relationship between inspiratory flow rate and amount of drug delivered into the lungs when using a fluticasone propionate dry powder inhaler with a Diskhaler (FP-DH). To investigate the amount of drug inhaled, we used an inhalation simulator, which consisted of a flow recorder placed in a plastic air-tight box that covered the FP-DH equipped with a twin impinger and a vacuum pump. Drugs located in a plastic box, as well as the device, throat, and stage 1 and stage 2, were assayed by HPLC-UV, following in vitro inhalation at the various flow rates ranged from 18.7 to 77.3 l/min for 2 s. The relationship between peak inspiratory flow rate and amount of drug released from the device was analyzed. A positive linear correlation between the dose released from the device and amount of drug deposited in stage 2 was observed (r=0.899, p<0.001). The doses deposited in stage 2 were estimated to be 2.9 μg at a flow rate of 20 l/min, 6.6 μg at 30 l/min, 8.4 μg at 40 l/min, 10.1 μg at 60 l/min, and 11.3 μg at 90 l/min. It was suggested that the amount of drug in the lungs decreased along with a decrease in peak inspiratory flow rate when it was lower than 60 l/min. Our results were found to be very useful to estimate lung deposition by using peak inspiratory flow rate for administration planning, especially in patients with a flow rate of less than 60 l/min.
30 October 2023 in Journal of Investigative Dermatology