Panagiotis Kosmas

Dr. Panagiotis Kosmas

Institute of Informatics and Telecommunications, National Center for Scientific Research “Demokritos”, Athens, Attikí, Greece
orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2010 in Medical Physics
Verified
Journal Article
Closed access
JSJacob D. Shea
Jacob D. Shea
Panagiotis KosmasPanagiotis Kosmas
Panagiotis Kosmas
SHSusan C. Hagness
Susan C. Hagness
BVBarry D. Van Veen
Barry D. Van Veen

11 July 2005 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
Panagiotis KosmasPanagiotis Kosmas
Panagiotis Kosmas
CRC.M. Rappaport
C.M. Rappaport
The feasibility of microwave breast cancer detection with a time-reversal (TR) algorithm is examined. This algorithm is based on the finite-difference time-domain method, and compensates for the wave decay and, therefore, is suitable for lossy media. In this paper, we consider a two-dimensional breast model based on magnetic resonance imaging data, and examine the focusing abilities of a TR mirror comprised of an array of receivers with a single ultra-wideband pulse excitation. In order to resolve small 3-mm-diameter tumors, a very short duration pulse is necessary, and this requirement may restrict the applicability of the system due to hardware limitations. We propose a way to overcome this obstacle based on the observation that the amplitude and phase information of the tumor response is sufficient to achieve focusing. The robustness of the TR algorithm with respect to breast inhomogeneities is demonstrated, and the good performance of the method suggests it is a promising technique for microwave breast cancer detection.

31 July 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SSShimul Saha
Shimul Saha
HCHelena Cano-Garcia
Helena Cano-Garcia
ISIoannis Sotiriou
Ioannis Sotiriou
OLOliver Lipscombe
Oliver Lipscombe
IGIoannis Gouzouasis
Ioannis Gouzouasis
EKEfthymios Kallos
Efthymios Kallos
We present a sensing system operating at millimetre (mm) waves in transmission mode that can measure glucose level changes based on the complex permittivity changes across the signal path. The permittivity of a sample can change significantly as the concentration of one of its substances varies: for example, blood permittivity depends on the blood glucose levels. The proposed sensing system uses two facing microstrip patch antennas operating at 60 GHz, which are placed across interrogated samples. The measured transmission coefficient depends on the permittivity change along the signal path, which can be correlated to the change in concentration of a substance. Along with theoretical estimations, we experimentally demonstrate the sensing performance of the system using controlled laboratory samples, such as water-based glucose-loaded liquid samples. We also present results of successful glucose spike detection in humans during an in-vivo Intravenous Glucose Tolerance Test (IVGTT). The system could eventually be developed into a non-invasive glucose monitor for continuous monitoring of glucose levels for people living with diabetes, as it can detect as small as 1.33 mmol/l (0.025 wt%) glucose concentrations in the controlled water-based samples satisfactorily, which is well below the typical human glucose levels of 4 mmol/l.

11 June 2010 in Inverse Problems
Verified
Journal Article
Closed access
JSJ D Shea
J D Shea
Panagiotis KosmasPanagiotis Kosmas
Panagiotis Kosmas
BVB D Van Veen
B D Van Veen
SHS C Hagness
S C Hagness
The detection of early-stage tumors in the breast by microwave imaging is challenged by both the moderate endogenous dielectric contrast between healthy and malignant glandular tissues and the spatial resolution available from illumination at microwave frequencies. The high endogenous dielectric contrast between adipose and fibroglandular tissue structures increases the difficulty of tumor detection due to the high dynamic range of the contrast function to be imaged and the low level of signal scattered from a tumor relative to the clutter scattered by normal tissue structures. Microwave inverse scattering techniques, used to estimate the complete spatial profile of the dielectric properties within the breast, have the potential to reconstruct both normal and cancerous tissue structures. However, the ill-posedness of the associated inverse problem often limits the frequency of microwave illumination to the UHF band within which early-stage cancers have sub-wavelength dimensions. In this computational study, we examine the reconstruction of small, compact tumors in three-dimensional numerical breast phantoms by a multiple-frequency inverse scattering solution. Computer models are also employed to investigate the use of exogenous contrast agents for enhancing tumor detection. Simulated array measurements are acquired before and after the introduction of the assumed contrast effects for two specific agents currently under consideration for breast imaging: microbubbles and carbon nanotubes. Differential images of the applied contrast demonstrate the potential of the approach for detecting the preferential uptake of contrast agents by malignant tissues.

10 February 2009 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DWDavid W. Winters
David W. Winters
JSJacob D. Shea
Jacob D. Shea
Panagiotis KosmasPanagiotis Kosmas
Panagiotis Kosmas
BVBarry D. Van Veen
Barry D. Van Veen
SHSusan C. Hagness
Susan C. Hagness
Breast imaging via microwave tomography involves estimating the distribution of dielectric properties within the patient's breast on a discrete mesh. The number of unknowns in the discrete mesh can be very large for 3-D imaging, and this results in computational challenges. We propose a new approach where the discrete mesh is replaced with a relatively small number of smooth basis functions. The dimension of the tomography problem is reduced by estimating the coefficients of the basis functions instead of the dielectric properties at each element in the discrete mesh. The basis functions are constructed using knowledge of the location of the breast surface. The number of functions used in the basis can be varied to balance resolution and computational complexity. The reduced dimension of the inverse problem enables application of a computationally efficient, multiple-frequency inverse scattering algorithm in 3-D. The efficacy of the proposed approach is verified using two 3-D anatomically realistic numerical breast phantoms. It is shown for the case of single-frequency microwave tomography that the imaging accuracy is comparable to that obtained when the original discrete mesh is used, despite the reduction of the dimension of the inverse problem. Results are also shown for a multiple-frequency algorithm where it is computationally challenging to use the original discrete mesh.

7 March 2017 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Closed access
ZMZhenzhuang Miao
Zhenzhuang Miao
Panagiotis KosmasPanagiotis Kosmas
Panagiotis Kosmas
A novel DBIM algorithm is proposed for microwave breast imaging based on the TwIST method. We show that this implementation is more flexible and robust than using traditional Krylov subspace methods such as the CGLS as solvers of the illposed linear problem. The paper presents several strategies to increase the algorithm’s robustness: a hybrid multi-frequency approach to achieve an optimal trade-off between imaging accuracy and reconstruction stability; a new approach to estimate the average breast tissues properties, based on sampling along their range of possible values and running a few DBIM iterations to find the minimum error; and finally, a new regularization strategy for the DBIM method based on the L1 norm and the Pareto curve. We present reconstruction examples which illustrate the benefits of these optimization strategies, which have resulted in a DBIM algorithm that outperforms our previous implementations for microwave breast imaging.