Pan Li

Prof. Pan Li

orcid
Associate professor at Tianjin University of Science and Tec...

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

25 April 2017 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
DSDan Stoianovici
Dan Stoianovici
CJChanghan Jun
Changhan Jun
SLSunghwan Lim
Sunghwan Lim
Pan LiPan Li
Pan Li
DPDoru Petrisor
Doru Petrisor
KCKevin Cleary
Kevin Cleary
We report the development of a new robotic system for direct image-guided interventions (DIGI; images acquired at the time of the intervention). The manipulator uses our previously reported pneumatic step motors and is entirely made of electrically nonconductive, nonmetallic, and nonmagnetic materials. It orients a needle-guide with two degrees of freedom (DoF) about a fulcrum point located below the guide using an innovative remote center of motion parallelogram type mechanism. The depth of manual needle insertion is preset with a third DoF, located remotely of the manipulator. Special consideration was given to the kinematic accuracy and the structural stiffness. The manipulator includes registration markers for image-torobot registration. Based on the images, it may guide needles, drills, or other slender instruments to a target (OD <; 10 mm). Comprehensive preclinical tests were performed. The manipulator is MR safe (ASTM F2503-13). Electromagnetic compatibility (EMC) testing (IEC 60601-1-2) of the system shows that it does not conduct or radiate EM emissions. The change in the signal to noise ratio of the MRI due to the presence and motion of the robot in the scanner is below 1%. The structural stiffness at the needle-guide is 33 N/mm. The angular accuracy and precision of the manipulator itself are 0.177° and 0.077°. MRI-guided targeting accuracy and precision in vitro were 1.71 mm and 0.51 mm, at an average target depth of ~38 mm, with no adjustments. The system may be suitable for DIGI where 1.07 + 0.0031 · d [mm] accuracy lateral to the needle (2D) or 1.59 + 0.0031 · d [mm] in 3D is acceptable. The system is also multiimager compatible and could be used with other imaging modalities.

1 September 2015 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
Pan LiPan Li
Pan Li
JSJiang Shan
Jiang Shan
YYYan Yu
Yan Yu
JYJun Yang
Jun Yang
ZYZhiyong Yang
Zhiyong Yang

21 April 2018 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
Pan LiPan Li
Pan Li
ZYZhiyong Yang
Zhiyong Yang
JSJiang Shan
Jiang Shan

16 January 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Pan LiPan Li
Pan Li
JSJiang Shan
Jiang Shan
DLDong Liang
Dong Liang
ZYZhiyong Yang
Zhiyong Yang
YYYan Yu
Yan Yu
WWWei Wang
Wei Wang
Steerable needles can potentially improve the effectiveness of diagnostic and therapeutic procedures, such as biopsy and cancer treatment, by increasing the targeting accuracy and reaching previously inaccessible targets. A discrete potential field algorithm based on three dimensional (3D) anatomical structures is proposed in this paper to plan the needle path in minimally invasive surgery. A 3D kinematic model of needle steering is formulated using Lie group theory. Model parameters are fitted using experimental data acquired via a 2-degree of freedom robotic device and an ultrasound imaging device. To execute the paths with variable curvatures, the model is incorporated with duty cycled spinning. Empirical formula between needle curvature and duty cycled factor is obtained through insertion experiments. To improve the targeting accuracy, a path tracking algorithm is developed by correcting for the heading error and cross-track error of the needle tip. The targeting error of the simulation is 0.29 mm. We experimentally evaluate the path tracking model and it achieves an average targeting error of 1.15 ± 0.56 mm in 3D environments with anatomical obstacles. The results of simulation are in agreement with steering experiments, showing that the discrete potential field algorithm and path tracking model have the potential to improve targeting accuracy and advance the therapeutic and diagnostic procedures.

4 November 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
XZXiaodong Zhong
Xiaodong Zhong
TATess Armstrong
Tess Armstrong
MNMarcel Dominik Nickel
Marcel Dominik Nickel
SKStephan A.R. Kannengiesser
Stephan A.R. Kannengiesser
Pan LiPan Li
Pan Li
HWHolden Wu
Holden Wu