Antonios A. Papadakis

Dr. Antonios A. Papadakis

Shcool of Medicine, School of Medicine, University of Crete, Heraklion, Greece
+1
orcid
Thank you for visiting my profile. My work focuses on public...

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
DCDimosthenis Chochlakis
Dimosthenis Chochlakis
VSVassilios Sandalakis
Vassilios Sandalakis
MKMaria Keramarou
Maria Keramarou
YTYannis Tselentis
Yannis Tselentis
APAnna Psaroulaki
Anna Psaroulaki
Several Travel-associated Legionnaires’ disease (TALD) cases occur annually in Europe. Except from the most obvious sites (cooling towers and hot water systems), infections can also be associated with recreational, water feature, and garden areas of hotels. This argument is of great interest to better comprehend the colonization and to calculate the risk to human health of these sites. From July 2000–November 2017, the public health authorities of the Island of Crete (Greece) inspected 119 hotels associated with TALD, as reported through the European Legionnaires’ Disease Surveillance Network. Five hundred and eighteen samples were collected from decorative fountain ponds, showers near pools and spas, swimming pools, spa pools, garden sprinklers, drip irrigation systems (reclaimed water) and soil. Of those, 67 (12.93%), originating from 43 (35.83%) hotels, tested positive for Legionella (Legionella pneumophila serogroups 1, 2, 3, 6, 7, 8, 13, 14, 15 and non-pneumophila species (L. anisa, L. erythra, L. taurinensis, L. birminghamensis, L. rubrilucens). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for chlorine concentrations of less than 0.2 mg/L (R.R.: 54.78), star classification (<4) (R.R.: 4.75) and absence of Water Safety Plan implementation (R.R.: 3.96). High risk (≥104 CFU/L) was estimated for pool showers (16.42%), garden sprinklers (7.46%) and pool water (5.97%).

17 February 2022 in PLOS Neglected Tropical Diseases
Verified
Journal Article
Open access
PDF file
EFEmmanouil A. Fotakis
Emmanouil A. Fotakis
KMKonstantinos Mavridis
Konstantinos Mavridis
AKAnastasia Kampouraki
Anastasia Kampouraki
SBSofia Balaska
Sofia Balaska
FTFilianna Tanti
Filianna Tanti
JVJohn Vontas
John Vontas
Background: In Greece vector borne diseases (VBD) and foremost West Nile virus (WNV) pose an important threat to public health and the tourist industry, the primary sector of contribution to the national economy. The island of Crete, is one of Greece’s major tourist destinations receiving annually over 5 million tourists making regional VBD control both a public health and economic priority.Methodology: Under the auspices of the Region of Crete, a systematic integrative surveillance network targeting mosquitoes and associated pathogens was established in Crete for the years 2018–2020. Using conventional and molecular diagnostic tools we investigated the mosquito species composition and population dynamics, pathogen infection occurrences in vector populations and in sentinel chickens, and the insecticide resistance status of the major vector species.Principal findings: Important disease vectors were recorded across the island includingCulex pipiens,Aedes albopictus, andAnopheles superpictus. Over 75% of the sampled specimens were collected in the western prefectures potentially attributed to the local precipitation patterns, withCx.pipiensbeing the most dominant species. Although no pathogens (flaviviruses) were detected in the analysed mosquito specimens, chicken blood serum analyses recorded a 1.7% WNV antibody detection rate in the 2018 samples. Notably detection of the first WNV positive chicken preceded human WNV occurrence in the same region by approximately two weeks. The chitin synthase mutation I1043F (associated with high diflubenzuron resistance) was recorded at an 8% allelic frequency in Lasithi prefectureCx.pipiensmosquitoes (sampled in 2020) for the first time in Greece. Markedly,Cx.pipienspopulations in all four prefectures were found harboring thekdrmutations L1014F/C/S (associated with pyrethroid resistance) at a close to fixation rate, with mutation L1014C being the most commonly found allele (≥74% representation). Voltage gated sodium channel analyses inAe.albopictusrevealed the presence of thekdrmutations F1534C and I1532T (associated with putative mild pyrethroid resistance phenotypes) yet absence of V1016G. Allele F1534C was recorded in all prefectures (at an allelic frequency range of 25–46.6%) while I1532T was detected in populations from Chania, Rethymnon and Heraklion (at frequencies below 7.1%). Finally, nokdrmutations were detected in theAnophelesspecimens included in the analyses.Conclusions/Significance: The findings of our study are of major concern for VBD control in Crete, highlighting (i) the necessity for establishing seasonal integrated entomological/pathogen surveillance programs, supporting the design of targeted vector control responses and; ii) the need for establishing appropriate insecticide resistance management programs ensuring the efficacy and sustainable use of DFB and pyrethroid based products in vector control.

25 May 2020 in Experimental and Therapeutic Medicine
Verified
Journal Article
Open access
PDF file
DKDimitrios Keramydas
Dimitrios Keramydas
PBPetros Bakakos
Petros Bakakos
MAManos Alchanatis
Manos Alchanatis
Petros G. PapalexisPetros G. Papalexis
Petros G. Papalexis
IKIoannis Konstantakopoulos
Ioannis Konstantakopoulos
ALAndreas C. Lazaris
Andreas C. Lazaris
Chronic exposure of workers to powder containing crystalline silica (Silicon dioxide; SiO2) can lead to chronic lung diseases (lung cancer, silicosis, etc.). Aim of this study was to evaluate the exposure of Greek construction workers to SiO2 and describe their pulmonary function. The study involved 86 outdoor and underground workers. Medical and professional history was obtained, and breath samples were collected at morning hours through a mask for the determination of SiO2 levels. Pulmonary function tests, radiological examination and evaluation of radiographs were also performed. Pulmonary function examination showed that the majority of the workers were within normal range (61.4%) while the rest were diagnosed with mild (26.5%) and more severe impairment (7.24%). Working conditions (underground‑outdoor) were statistically significantly related to the categorization of pulmonary function (P=0.038). During radiological examination, the type of working activity/ conditions (underground‑outdoor) were statistically significantly related to the categorization of these findings (P=0.044). Of the 69 employees, 52 did not present findings (75.4%) and 5 were diagnosed with findings specific to occupational diseases (7.23%). Environmental exposure to respirable crystalline silica (RCS) was detected at 0.0125 mg/m3 in the workplace, which is not beyond the legal limits. Underground workers with more than 15 years of exposure to SiO2 are more likely to present chronic silicosis compared to the workers of outdoor activities.

17 August 2021 in Water
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
MKMaria Keramarou
Maria Keramarou
DCDimosthenis Chochlakis
Dimosthenis Chochlakis
VSVassilios Sandalakis
Vassilios Sandalakis
Varvara MouchtouriVarvara Mouchtouri
Varvara Mouchtouri
APAnna Psaroulaki
Anna Psaroulaki
Hotel water systems colonized with Legionella spp. have been the source of travel-associated Legionnaires’ disease, and cases, clusters and outbreaks continue to be reported worldwide each year. A total of 132 hotels linked with travel-associated Legionnaires’ disease, as reported through the European Legionnaires’ Disease Surveillance Network, were inspected and tested for Legionella spp. during 2000–2019 by the public health authorities of the island of Crete (Greece). A total of 3311 samples were collected: 1885 (56.93%) from cold water supply systems, 1387 (41.89%) from hot water supply systems, 37 (1.12%) were swab samples and two (0.06%) were soil. Of those, 685 (20.69%), were collected from 83 (62.89%) hotels, testing positive (≥50 CFU/L) for Legionella pneumophila) serogroups 1–10, 12–14 and non-pneumophila species (L. anisa, L. erythra, L. tusconensis, L. taurinensis, L. birminghamensis, L. rubrilucens, L. londiniesis, L. oakridgensis, L. santicrusis, L. brunensis, L. maceacherii). The most frequently isolated L. pneumophila serogroups were 1 (27.92%) and 3 (17.08%). Significantly higher isolation rates were obtained from hot water supply systems (25.96%) versus cold water systems (16.98%) and swab samples (13.51%). A Relative Risk (R.R.) > 1 (p < 0.0001) was calculated for hot water temperature <55 °C (R.R.: 4.43), chlorine concentrations <0.2 mg/L (R.R.: 2.69), star ratings <4 (R.R.: 1.73) and absence of Water Safety Plan implementation (R.R.: 1.57).

22 June 2023 in Medicine International
Verified
Journal Article
Open access
PDF file
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
ITIoannis Tsirigotakis
Ioannis Tsirigotakis
SKSofia Katranitsa
Sofia Katranitsa
CDChristos Donousis
Christos Donousis
PPPetros Papalexis
Petros Papalexis
TCTheodoros C. Constantinidis
Theodoros C. Constantinidis
With the onset of the coronavirus disease 2019 (COVID‑19) pandemic, numerous countries imposed strict lockdown measures and travel bans, resulting in the closure of hotels. Over time, the opening of hotel units was gradually allowed, and new strict regulations and protocols were issued to ensure the hygiene and safety of swimming pools in the era of COVID‑19. The present study aimed to evaluate the implementation of strict health COVID‑19‑related protocols in hotel units during the 2020 summer tourist season concerning microbiological hygiene and physicochemical parameters of water, and to compare the data with those from the 2019 tourist season. For this reason, 591 water samples from 62 swimming pools were analyzed, of which 381 samples were for the 2019 tourist season and 210 samples were for the 2020 tourist season. To examine the presence of Legionella spp, 132 additional samples were taken from 14 pools, of which 49 in 2019 and 83 in 2020. In 2019, 2.89% (11/381) of the samples were out of legislative limits (0/250 mg/l) regarding the presence of Escherichia coli (E. coli), 9.45% (36/381) were out of acceptable limits (0/250 mg/l) regarding the presence of Pseudomonas aeruginosa (P. aeruginosa) and 8.92% (34/381) had residual chlorine levels <0.4 mg/l. In 2020, 1.43% (3/210) of the samples were out of the legislative limits as regards the presence of E. coli, 7.14% (15/210) were out of acceptable limits regarding the presence of P. aeruginosa and 3.33% (7/210) of the samples measured residual chlorine levels <0.4 mg/l. The risk ratio (RR) in relation to the presence of E. coli due to incorrect compliance with the requirements for residual chlorine was calculated for 2019 at 8.50, while in 2020 it was calculated at 14.50 (P=0.008). The RR of the presence of P. aeruginosa due to inappropriate residual chlorine requirements was calculated in 2019 at 2.04 (P=0.0814), while in 2020 it was calculated at 2.07 (P=0.44). According to the microbiological hygiene and physicochemical parameters of the water samples studied, there was a significant improvement due to the strict protocols for the swimming pools in the summer season of 2020 compared to the tourist season of 2019, namely 72.72% (E. coli), 58.33% (P. aeruginosa), 79.41% (of residual chlorine <0.4 mg/l) in the three main parameters studied. Finally, an increased colonization by Legionella spp. detected in the internal networks of the hotels due to the non‑operation of the hotels during the lockdown, the improper disinfection and stagnant water in the internal water supply networks. Specifically, in 2019, 95.92% (47/49) of the samples tested negative and 4.08% (2/49) tested positive (≥50 CFU/l) for Legionella spp., compared to 2020 where 91.57% (76/83) of the samples tested negative and 8.43% (7/83) tested positive.

LALemonia Anagnostopoulos
Lemonia Anagnostopoulos
LKLeonidas Kourentis
Leonidas Kourentis
Antonios A. PapadakisAntonios A. Papadakis
Antonios A. Papadakis
Varvara MouchtouriVarvara Mouchtouri
Varvara Mouchtouri
Coronavirus disease (COVID-19) outbreaks on board cruise ships early in the pandemic highlighted gaps worldwide in public health emergency contingency plans (PHECPs) for responding to unknown threats. To restart cruise operations in 2021 and respond to potential COVID-19 outbreaks, a major tourist-based Greek island port (Port A) developed a COVID-19 PHECP. We assessed plan effectiveness by reviewing epidemiological data and monitoring outcomes, followed by an intra-action review (IAR) analyzing three event responses. From May to December 2021, 118 calls from 23 cruise ships with 119,930 passengers were recorded, with 29 COVID-19 cases in 11 cruises on board 7 ships. No outbreak was recorded during the study period. Strengths of the introduced PHECP included commitment of senior management; a core multi-disciplinary team of local authorities/ship agents involved in design and execution; interoperability agreements for port and ships’ PHECPs; cruise industry commitment to compliance; and pre-existing scenarios considering capacity needs. Central government coordination for preparedness planning at local ports is essential for successful responses. Monitoring local and country level response capacities is critical to inform planning, risk assessment, and decision-making. Immediately recording ports’ response actions provides the basis to capture lessons and improve contingency plans. To facilitate communication and common response protocols between European and non-European ports, IARs should be conducted between countries.
1