Early diagnosis and accurate assessment of tumor development facilitate early bladder cancer resection and initiation of drug therapy. This study enabled an early, accurate, label-free, noninvasive diagnosis of bladder tumors by analyzing nano-biomarkers in a single drop of urine through surface-enhanced Raman spectroscopy (SERS). In a standard N-butyl-N-4-hydroxybutyl nitrosamine-induced rat model of bladder cancer, cancer stage and polyp tumor development were monitored using a small endoscope with a diameter of 1.2 mm in a minimally invasive manner without the need to kill the rats. Samples were divided into cancer-free, early-stage, and polyp-form cancer. Training data were classified according to micro-cystoscopic 5-aminolevulinic acid fluorescence diagnosis, and specimens were postmortem verified through histopathological analysis. A drop of urine from each sample group was placed on an Au-coated zinc oxide nanoporous chip to filter nano-biomaterials and selectively enhance the Raman signals of nanoscale analytes via SERS. Principal component analysis was used to reduce the dimensionality of the collected Raman spectra, and partial least squares discriminant analysis was used to find diagnostic clusters based on the labeled samples. The combination of SERS and machine learning achieved an accuracy ≥99.6% in diagnosing both early- and polyp-stage bladder tumors. With an area under the receiver operating characteristic curve greater than 0.996, the accuracy of the diagnosis in the rat model suggests that SERS-based diagnostic methods are promising when coupled with machine learning. Low-cost, label-free, and noninvasive surface-enhanced Raman spectra are ideal for developing clinically relevant point-of-care diagnostic techniques.
14 July 2021 in IEEE Transactions on Biomedical Engineering
Objective: To enable a real-time surgical guidance system that simultaneously monitors blood vessel perfusion, oxygen saturation, thrombosis, and tissue recovery by combining multiple optical imaging techniques into a single system: visible imaging, mosaic filter-based snapshot hyperspectral imaging (HSI), and laser speckle contrast imaging (LSCI). Methods: The multimodal optical imaging system was demonstrated by clamping blood vessels in the small intestines of rats to create areas of restricted blood flow. Subsequent tissue damage and regeneration were monitored during procedures. Using LSCI, vessel perfusion was measured, revealing the biological activity and survival of organ tissues. Blood oxygen saturation was monitored using HSI in the near-infrared region. Principal component analysis was used over the spectral dimension to identify an HSI wavelength combination optimized for hemodynamic biomarker visualization. HSI and LSCI were complimentary, identifying thrombus generation and tissue recovery, which was not possible in either modalityalone. Results and Conclusion: By analyzing multimodal tissue information from visible imaging, LSCI perfusion imaging, and HSI, a recovery prognosis could be determined based on the blood supply to the organ. The unique combination of the complementary imaging techniques into a single surgical microscope holds promise for improving the real-time determination of blood supply and tissue prognosis during surgery. Significance: Precise real-time monitoring for vascular anomalies promises to reduce the risk of organ damage in precise surgical operations such as tissue resection and transplantation. In addition, the convergence of label-free imaging technologies removes delays associated with the injection and diffusion of vascular monitoring dyes.
The cell nucleus is a three-dimensional, dynamic organelle organized into subnuclear compartments such as chromatin and nucleoli. The structure and function of these compartments are maintained by diffusion and interactions between related factors as well as by dynamic and structural changes. Recent studies using fluorescent microscopic techniques suggest that protein factors can access and are freely mobile in heterochromatin and in mitotic chromosomes, despite their densely packed structure. However, the physicochemical properties of the chromosome during cell division are not fully understood. In the present study, characteristic properties such as the refractive index (RI), volume of the mitotic chromosomes, and diffusion coefficient (D) of fluorescent probes inside the chromosome were quantified using an approach combining label-free optical diffraction tomography with complementary confocal laser-scanning microscopy and fluorescence correlation spectroscopy. Variations in these parameters correlated with osmotic conditions, suggesting that changes in RI are consistent with those of the diffusion coefficient for mitotic chromosomes and cytosol. Serial RI tomography images of chromosomes in live cells during mitosis were compared with three-dimensional confocal micrographs to demonstrate that compaction and decompaction of chromosomes induced by osmotic change were characterized by linked changes in chromosome RI, volume, and the mobilities of fluorescent proteins.
1 November 2018 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
The quest to reduce kidney transplant rejection has emphasized the urgent requirement for the development of non-invasive, precise diagnostic technologies. These technologies aim to detect antibody-mediated rejection (ABMR) and T-cell-mediated rejection (TCMR), which are asymptomatic and pose a risk of potential kidney damage. The protocols for managing rejection caused by ABMR and TCMR differ, and diagnosis has traditionally relied on invasive biopsy procedures. Therefore, a convergence system using a nano-sensing chip, Raman spectroscopy, and AI technology was introduced to facilitate diagnosis using serum samples obtained from patients with no major abnormality, ABMR, and TCMR after kidney transplantation. Tissue biopsy and Banff score analysis were performed across the groups for validation, and 5 μL of serum obtained at the same time was added onto the Au-ZnO nanorod-based Surface-Enhanced Raman Scattering sensing chip to obtain Raman spectroscopy signals. The accuracy of machine learning algorithms for principal component-linear discriminant analysis and principal component-partial least squares discriminant analysis was 93.53% and 98.82%, respectively. The collagen (an indicative of kidney injury), creatinine, and amino acid-derived signals (markers of kidney function) contributed to this accuracy; however, the high accuracy was primarily due to the ability of the system to analyze a broad spectrum of various biomarkers.
Nanorods based on ZnO for surface enhanced Raman spectroscopy are promising for the non-invasive and rapid detection of biomarkers and diagnosis of disease. However, optimization of nanorod and coating parameters is essential to their practical application. With the goal of establishing a baseline for early detection in biological applications, gold-coated ZnO nanorods were grown and coated to form porous structures. Prior to gold deposition, the grown nanorods were 30–50 nm in diameter and 500–600 nm in length. Gold coatings were grown on the nanorod structure to a series of thicknesses between 100 and 300 nm. A gold coating of 200 nm was found to optimize the Rhodamine B model analyte signal, while performance for rat urine depended on the biomarkers to be detected. These results establish design guidelines for future use of Au-ZnO nanorods in the study and early diagnosis of inflammatory diseases.