George Pitchurov

Dr. George Pitchurov

orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Building and Environment
Verified
Journal Article
Closed access
George PitchurovGeorge Pitchurov
George Pitchurov
JSJelena Srebric
Jelena Srebric
SZShengwei Zhu
Shengwei Zhu
RVRichard L. Vincent
Richard L. Vincent
PBPhilip W. Brickner
Philip W. Brickner
SRStephen N. Rudnick
Stephen N. Rudnick

22 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Detelin MarkovDetelin Markov
Detelin Markov
Nikolay IvanovNikolay Ivanov
Nikolay Ivanov
George PitchurovGeorge Pitchurov
George Pitchurov
Marina ZasimovaMarina Zasimova
Marina Zasimova
PSPeter A. Stankov
Peter A. Stankov
RVRositsa Velichkova
Rositsa Velichkova
The objective of the paper is to demonstrate the importance of the unsteady Computational Fluid Dynamics (CFD) simulations and long-term measurements for the reliable assessment of thermal comfort indoors, for proper categorization of the indoor thermal environment and for identifying the reasons for complaints due to draught discomfort. Numerical simulations and experimental measurements were applied in combination to study ventilation in a field laboratory, a university classroom with a controlled indoor environment. Strong unsteadiness of the airflow was registered both in the unsteady RANS results and the real-scale long-term velocity data measured with thermo anemometer. Low-frequency high-amplitude velocity fluctuations observed lead to substantial time variation of the draught rate. In case of categorization of a thermal environment, the point measurements or steady-state RANS computations would lead to wrong conclusions as well as they cannot be used for identification of the reasons for people’s complaints due to draught discomfort if strong unsteadiness of the airflow exists. It is demonstrated that the length of the time interval for draught rate (DR) assessment may not be universal if low-frequency high-amplitude pulsations are present in the room airflow.

28 October 2014 in International Journal of Clothing Science and Technology
Verified
Journal Article
Closed access
George PitchurovGeorge Pitchurov
George Pitchurov
Radostina AngelovaRadostina Angelova
Radostina Angelova
ISIskra Simova
Iskra Simova
IRIosu Rodrigo
Iosu Rodrigo
PSPeter A. Stankov
Peter A. Stankov
Purpose: – The purpose of this paper is to integrate a thermophysiological human body model into a CFD simulation to predict the dry and latent body heat loss, the clothing, skin and core temperature, skin wettedness and periphery blood flow distribution. The integration of the model allows to generate more realistic boundary conditions for the CFD simulation and allows to predict the room distribution of temperature and humidity originating from the occupants. Design/methodology/approach: – A two-dimensional thermophysiological body model is integrated into a CFD simulation to predict the interaction between the human body and room environment. Parameters varied were clothing insulation and metabolic activity and supply air temperature. The body dry and latent heat loss, skin wettedness, skin and core temperatures were predicted together with the room air temperature and humidity. Findings: – Clothing and metabolic activity were found to have different level of impact on the dry and latent heat loss. Heat loss was more strongly affected by changes in the metabolic rate than in the clothing insulation. Latent heat loss was found to exhibit much larger variations compared to dry heat loss due to the high latent heat potential of water. Originality/value: – Unlike similar studies featuring naked human body, clothing characteristics like sensible resistance and vapor permeability were accommodated into the present study. A method to ensure numerical stability of the integrated simulation was developed and implemented to produce robust and reliable simulation performance.

28 July 2013 in Open Engineering
Verified
Journal Article
Open access
PDF file
George PitchurovGeorge Pitchurov
George Pitchurov
PSPeter A. Stankov
Peter A. Stankov
A two-node mathematical model of the human thermophysiological system has been integrated into a Computational Fluid Dynamic (CFD) simulation of the airflow in a room. Temperature inputs from the CFD are used by the model to evaluate the dry and latent heat flux from the body surface and output them as boundary conditions. This is an iterative process and convergence is ensured by under-relaxation of the latent heat flux. The model also considers the dry and latent heat resistance of clothing. Numerical predictions of the body heat loss and airflow are compared against physical measurements in a climate chamber. Good agreement was observed when using the low Reynolds number turbulence model. The integrated simulation performs well under wide set of conditions, predicting body core and skin temperature, blood flow, skin wittedness, as well as the transfer of heat and moisture released by the body into the room.

2 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Angel K. TerzievAngel K. Terziev
Angel K. Terziev
Florin Ioan BodeFlorin Ioan Bode
Florin Ioan Bode
Penka ZlatevaPenka Zlateva
Penka Zlateva
George PitchurovGeorge Pitchurov
George Pitchurov
MIMartin Ivanov
Martin Ivanov
BSBorislav Nikolov Stankov
Borislav Nikolov Stankov
Tree belts are commonly applied over agricultural terrain where seeds of wheat and other vegetation are planted in the ground in order to prevent the seeds from being blown by the wind. The tree belt comprises a long and thin (10–20 m thick) section of trees, which spans in a direction normal to the prevailing wind direction. While serving its agricultural goal, the belt does inevitably modify the boundary layer profile of the wind. This, on its part, is likely to affect the operation of small-scale wind turbines installed in the vicinity of the belt. The goal of this study is to determine the span and range at which this effect manifests itself. It was found that in the near vicinity downstream and slightly above the tree belt, the wind velocity actually increased due to the mass conservation. The flow became independent on the tree belt drag coefficient when its value was higher than 0.2 1/m. The turbulence introduced by the belt was restricted to a height of 1.5–2 tree belts.

25 February 2026 in Thermo
Verified
Journal Article
Open access
PDF file
Masoud SahamiMasoud Sahami
Masoud Sahami
HGHojat Ghassemi
Hojat Ghassemi
Angel K. TerzievAngel K. Terziev
Angel K. Terziev
Kostadin FikiinKostadin Fikiin
Kostadin Fikiin
BSBorislav Nikolov Stankov
Borislav Nikolov Stankov
MIMartin Ivanov
Martin Ivanov
The rapid evaporation of liquid droplets across a normal shock wave is a phenomenon of critical importance in advanced propulsion and clean energy systems, such as NH3 supersonic separation. The conventional Spalding d2-law is commonly used to model such phenomena, but it is not suitable for predicting the complete vaporization of sub-micron droplets, particularly as evaporation approaches the free-molecular regime. To address this issue, this paper introduces a novel time-dependent one-dimensional CFD model, which is used to analyze the shock structure, the non-equilibrium heat and mass transfer between the liquid and gas phases, and the evolution of the droplets’ size through the shock. The model describes the evaporation of NH3 sub-micron droplet sprays across a stationary normal shock for various fractions of the liquid phase. The Gyarmathy evaporation model is utilized to accurately account for the transition from diffusion-governed to free-molecular regimes, alongside a new two-phase Rankine–Hugoniot shock jump formulation. The study reveals the influence of a steady normal shock on the physical structure of a droplet-laden flow, including the existence of an initial droplet size swelling through the shock, and quantifies the subsequent complete evaporation of the suspended droplets. The maximum swelling throughout the shock is up to 17%, which corresponds to the case with 8% liquid phase mass fraction in the flow. The model provides acceptable accuracy in calculating the two-phase parameters in high-speed flows and can be extended for modeling more complex, multidimensional detonation and propulsion systems.