Although there are specific and general digital scanning guidelines depending on the system used, it is important to have the necessary flexibility in the acquisition of three-dimensional (3D) images to adapt to any clinical situation without affecting accuracy. The purpose of this in vitro study was to identify and compare the scanning strategy with the greatest accuracy, in terms of trueness and precision, of four intraoral scanners in the impression of a complete dental arch. Four digital scanners were evaluated with a 3D measuring software, using a highly accurate reference model obtained from an industrial scanner as a comparator. Four scanning strategies were applied 10 times on a complete maxillary arch cast inside a black methacrylate box. The data were statistically analyzed using one-way analysis of variance (ANOVA) and post hoc comparisons with Tamhane T2 test. The trueness of the Trios and iTero system showed better results with strategy “D,” Omnicam with strategy “B,” and True Definition with strategy “C”. In terms of precision, both iTero and True Definition showed better results with strategy “D”, while Trios showed best results with strategy “A” and Omnicam with strategy “B”. There were significant differences between the scanning strategies (p0.05). The digital impression systems used in the experiment provided sufficient flexibility for the acquisition of 3D images without this affecting the accuracy of the scanner.
The scanner does not measure the dental surface continually. Instead, it generates a point cloud, and these points are then joined to form the scanned object. This approximation will depend on the number of points generated (resolution), which can lead to low accuracy (trueness and precision) when fewer points are obtained. The purpose of this study is to determine the resolution of four intraoral digital imaging systems and to demonstrate the relationship between accuracy and resolution of the intraoral scanner in impressions of a complete dental arch. A master cast of the complete maxillary arch was prepared with different dental preparations. Using four digital impression systems, the cast was scanned inside of a black methacrylate box, obtaining a total of 40 digital impressions from each scanner. The resolution was obtained by dividing the number of points of each digital impression by the total surface area of the cast. Accuracy was evaluated using a three-dimensional measurement software, using the "best alignment" method of the casts with a highly faithful reference model obtained from an industrial scanner. Pearson correlation was used for statistical analysis of the data. Of the intraoral scanners, Omnicam is the system with the best resolution, with 79.82 points per mm2, followed by True Definition with 54.68 points per mm2, Trios with 41.21 points per mm2, and iTero with 34.20 points per mm2. However, the study found no relationship between resolution and accuracy of the study digital impression systems (P >0.05), except for Omnicam and its precision. The resolution of the digital impression systems has no relationship with the accuracy they achieve in the impression of a complete dental arch. The study found that the Omnicam scanner is the system that obtains the best resolution, and that as the resolution increases, its precision increases. Key words:Trueness, precision, accuracy, resolution, intraoral scanner, digital impression.
Digital impresión allows the dentist to directly obtain the data of the dental pieces that neet to be rehabilitated, giving it greater precisión and thus eliminating the impression and manufacturing of the dental model, error-sensitive aspects of the clinical phase. The aim of this review is to identify the most accurate intraoral digital impression system and identifiy the factors that affect the accuracy in the restorative dentistry. Through a bibliographic review with search in PubMed and Embase databases, 153 articles were obtained, after qualitative evaluation they were included in the revisión 14 that met the inclusion and exclusion criteria. It was determined that the experience of the dentist, the convergence in the dental preparation and the cervical termination are decisive at the accuracy of the digital impression, however, the use or not of dust is not relevant. The Lava C.O.S., iTero and True definition are the most accurate always depending on the type of rehabilitation to be performed.
1 January 2023 in Journal of Clinical and Experimental Dentistry
To determine the operative time and the internal restoration gap in the restoration–tooth interface in the cavity floor using an incremental technique for conventional resins and the single-increment technique for the bulk fill resin. In this in vitro experimental study, the internal gaps of the restoration–tooth interfaces in the cavity floors of two conventional resins and two bulk fill resins were microscopically analyzed, and the restoration times of the single-increment technique and the incremental technique were determined. Bulk fill resins had smaller internal gap (63.31 µm) than conventional resins (333.14 µm). Regarding the restoration time, the single-increment technique obtained the best results in operative time (3.52 minutes), with significant differences relative to the incremental technique. The Tetric N-Ceram bulk fill resin presented better performance than conventional resins relative to the internal gap of the restoration–tooth interface in the cavity floor. In addition, the single-increment technique presented a short clinical restoration time. Key words:Composite, internal gap, restoration technique.