PEDRO INÁCIO

Mr. PEDRO INÁCIO

University of Algarve, Faro, Portugal
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Youssef ElamineYoussef Elamine
Youssef Elamine
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
BLBadiâa Lyoussi
Badiâa Lyoussi
Ofélia AnjosOfélia Anjos
Ofélia Anjos
Leticia M. EstevinhoLeticia M. Estevinho
Leticia M. Estevinho
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes

1 October 2020 in Organic Electronics
Verified
Journal Article
Closed access
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
MMMaria Medeiros
Maria Medeiros
TCTiago Carvalho
Tiago Carvalho
RFRute C. Félix
Rute C. Félix
AMAna Mestre
Ana Mestre
HGHenrique L. Gomes
Henrique L. Gomes

27 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AMAna L. G. Mestre
Ana L. G. Mestre
MCMónica Cerquido
Mónica Cerquido
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
SASanaz Asgarifar
Sanaz Asgarifar
ALAna S. Lourenço
Ana S. Lourenço
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
Ultra-sensitive electrodes for extracellular recordings were fabricated and electrically characterized. A signal detection limit defined by a noise level of 0.3–0.4 μV for a bandwidth of 12.5 Hz was achieved. To obtain this high sensitivity, large area (4 mm2) electrodes were used. The electrode surface is also micro-structured with an array of gold mushroom-like shapes to further enhance the active area. In comparison with a flat gold surface, the micro-structured surface increases the capacitance of the electrode/electrolyte interface by 54%. The electrode low impedance and low noise enable the detection of weak and low frequency quasi-periodic signals produced by astrocytes populations that thus far had remained inaccessible using conventional extracellular electrodes. Signals with 5 μV in amplitude and lasting for 5–10 s were measured, with a peak-to-peak signal-to-noise ratio of 16. The electrodes and the methodology developed here can be used as an ultrasensitive electrophysiological tool to reveal the synchronization dynamics of ultra-slow ionic signalling between non-electrogenic cells.

1 September 2016 in Sensing and Bio-Sensing Research
Verified
Journal Article
Open access
MMMaria Medeiros
Maria Medeiros
AMAna Mestre
Ana Mestre
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
SASanaz Asgarif
Sanaz Asgarif
Inês AraújoInês Araújo
Inês Araújo
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
An electrical method to measure extracellular bioelectrical activity in vitro is presented. This method exploits the Helmholtz capacitive double-layer established at the electrode surface. Small extracellular voltage variations in the order of μVs induce through the double-layer capacitor a displacement current that is measured. This current is then enhanced by a gain factor proportional to the electrode capacitance. In addition, when measurements are carried out at low frequencies in current mode the electrode contribution to the noise can be minimized. The performance of the electrodes and the method is demonstrated using zebrafish hearts and glioma cell cultures. We propose that this electrical method is an ideal tool to measure in vitro slow and temporally synchronized events that are often involved in long range intracellular signaling

11 May 2017 in IEEE Sensors Journal
Verified
Journal Article
Closed access
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
AMAna L. G. Mestre
Ana L. G. Mestre
MMMaria Medeiros
Maria Medeiros
SASanaz Asgarifar
Sanaz Asgarifar
Youssef ElamineYoussef Elamine
Youssef Elamine
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
Conducting polymer electrodes based on poly (3, 4 ethylenedioxythiophene):polystyrene sulfonate were used to record electrophysiological signals from autonomous cardiac contractile cells present in embryoid bodies. Signal detection was carried out by measuring the displacement current across the polymer/electrolyte double-layer capacitance, and compared with voltage detection. While for relatively low capacitance electrodes, the voltage amplification provides higher signal quality, and for high capacitive electrodes, the displacement current method exhibits a higher signal-to-noise ratio. It is proposed that the displacement current method combined with high capacitive polymer-based electrodes is adequate to measure clusters of cells and whole organs. Our approach has a great potential in fundamental studies of drug discovery and safety pharmacology.

23 October 2017 in Frontiers in Neural Circuits
Verified
Journal Article
Open access
AMAna L. G. Mestre
Ana L. G. Mestre
PEDRO INÁCIOPEDRO INÁCIO
PEDRO INÁCIO
Youssef ElamineYoussef Elamine
Youssef Elamine
SASanaz Asgarifar
Sanaz Asgarifar
ALAna S. Lourenço
Ana S. Lourenço
Henrique Leonel GomesHenrique Leonel Gomes
Henrique Leonel Gomes
Astrocytes are neural cells that exhibit functional electrical properties sensitive to neuronal activity and capable of modulating neurotransmission. Thus, electrophysiological recordings of astroglial activity are very attractive to study the dynamics of glial signaling. This contribution reports on the use of ultra-sensitive planar electrodes combined with low noise and low frequency amplifiers that enable the detection of extracellular signals produced by primary cultures of astrocytes isolated from rat cerebral cortex. Recorded activity is characterized by spontaneous bursts comprised of discrete signals with pronounced changes on the spike rate and amplitude. Weak and sporadic signals become synchronized and evolve with time to higher amplitude signals with a quasi-periodic behavior, revealing a cooperative signaling mechanism. The methodology presented herewith enables the study of ionic fluctuations of population of cells, complementing the single cells observation by calcium imaging as well as by patch-clamp techniques.