The non-intrusive density measurement of the thin plasma produced by a mini-helicon space thruster (HPH.com project) is a challenge, due to the broad density range (between 1016 m−3 and 1019 m−3) and the small size of the plasma source (2 cm of diameter). A microwave interferometer has been developed for this purpose. Due to the small size of plasma, the probing beam wavelength must be small (λ = 4 mm), thus a very high sensitivity interferometer is required in order to observe the lower density values. A low noise digital phase detector with a phase noise of 0.02° has been used, corresponding to a density of 0.5 × 1016 m−3.
The main role of the ITER Radial Neutron Camera (RNC) diagnostic is to measure in real-time the plasma neutron emissivity profile at high peak count rates for a time duration up to 500 s. Due to the unprecedented high performance conditions and after the identification of critical problems, a set of activities have been selected, focused on the development of high priority prototypes, capable to deliver answers to those problems before the final RNC design. This paper presents one of the selected activities: the design, development and testing of a dedicated FPGA code for the RNC Data Acquisition prototype. The FPGA code aims to acquire, process and store in real-time the neutron and gamma pulses from the detectors located in collimated lines of sight viewing a poloidal plasma section from the ITER Equatorial Port Plug 1. The hardware platform used was an evaluation board from Xilinx (KC705) carrying an IPFN FPGA Mezzanine Card (FMC-AD2-1600) with 2 digitizer channels of 12-bit resolution sampling up to 1.6 Gsamples/s. The code performs the proper input signal conditioning using a down-sampled configuration to 400 Msamples/s, apply dedicated algorithms for pulse detection, filtering and pile up detection, and includes two distinct data paths operating simultaneously: i) the event-based data-path for pulse storage; and ii) the real-time processing, with dedicated algorithms for pulse shape discrimination and pulse height spectra. For continuous data throughput both data-paths are streamed to the host through two distinct PCIe x8 Direct Memory Access (DMA) channels.