Pier Paolo Poli

Dr. Pier Paolo Poli

University of Milan
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2014 in The Open Dentistry Journal
Verified
Journal Article
Open access
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
MBMario Beretta
Mario Beretta
Marco CicciùMarco Cicciù
Marco Cicciù
CMCarlo Maiorana
Carlo Maiorana
An adequate amount of bone all around the implant surface is essential in order to obtain long-term success of implant restoration. Several techniques have been described to augment alveolar bone volume in critical clinical situations, including guided bone regeneration, based on the use of barrier membranes to prevent ingrowth of the epithelial and gingival connective tissue cells. To achieve this goal, the use of barriers made of titanium micromesh has been advocated.A total of 13 patients were selected for alveolar ridge reconstruction treatment prior to implant placement. Each patient underwent a tridimensional bone augmentation by means of a Ti-mesh filled with intraoral autogenous bone mixed with deproteinized anorganic bovine bone in a 1:1 ratio. Implants were placed after a healing period of 6 months. Panoramic x-rays were performed after each surgical procedure and during the follow-up recalls. Software was used to measure the mesial and the distal peri-implant bone loss around each implant. The mean peri-implant bone loss was 1.743 mm on the mesial side and 1.913 mm on the distal side, from the top of the implant head to the first visible bone-implant contact, at a mean follow-up of 88 months.The use of Ti-mesh allows the regeneration of sufficient bone volume for ideal implant placement. The clinical advantages related to this technique include the possibility of correcting severe vertical atrophies associated with considerable reductions in width and the lack of major complications if soft-tissue dehiscence and mesh exposures do occur.

1 January 2017 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
CMCarlo Maiorana
Carlo Maiorana
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
MDMatteo Deflorian
Matteo Deflorian
Tiziano TestoriTiziano Testori
Tiziano Testori
FMFederico Mandelli
Federico Mandelli
RVRaffaele Vinci
Raffaele Vinci
Maiorana C, et al. J Periodontal Implant Sci. 2017 Aug;47(4):194-210. https://doi.org/10.5051/jpis.2017.47.4.194

1 January 2014 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
MBMario Beretta
Mario Beretta
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
CMCarlo Maiorana
Carlo Maiorana
Beretta M, et al. J Periodontal Implant Sci. 2014 Aug;44(4):184-193. http://dx.doi.org/10.5051/jpis.2014.44.4.184

1 February 2021 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
MBMario Beretta
Mario Beretta
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
STSebastian Tansella
Sebastian Tansella
MAMarco Aguzzi
Marco Aguzzi
AMAntonio Meoli
Antonio Meoli
CMCarlo Maiorana
Carlo Maiorana

12 September 2021 in Materials
Verified
Journal Article
Open access
PDF file
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
FMFábio Miranda
Fábio Miranda
TPTárik Ocon Braga Polo
Tárik Ocon Braga Polo
JJJOEL FERREIRA SANTIAGO JUNIOR
JOEL FERREIRA SANTIAGO JUNIOR
TNTiburtino José Lima Neto
Tiburtino José Lima Neto
LFLeonardo Faverani
Leonardo Faverani
(1) Background: Hypersensitivity reactions to metals may arise in predisposed patients chronically exposed to metallic materials, including dental implants made of titanium alloys. The purpose of this article was to systematically review titanium allergy manifestations in patients treated with dental implants and report a clinical case; (2) Methods: A systematic electronic search was performed for articles published in the English language until July 2021. The following eligibility criteria were adopted: (1) Population: individuals undergoing titanium and/or titanium alloy implant-supported rehabilitations; (2) Exposure: peri-implant soft tissue reactions attributable to implant insertion; (3) Outcome: evidence of titanium allergy, diagnostic methods, and forms of resolution; (3) Results: The included studies, in summary, presented evidence that titanium should not be considered an inert material, being able to trigger allergic reactions, and may be responsible for implant failure. A 55-year-old male patient received 3 implants in the posterior region of the left mandible and presented an epulis-like lesion developed from the peri-implant mucosa. The immunohistochemical analysis of the biopsy specimen confirmed the initial diagnosis of allergic reaction to titanium; (4) Conclusions: Although the evidence is weak, and titanium allergy has a low incidence, hypersensitivity reactions should not be underestimated. A rapid and conclusive diagnosis is mandatory to prevent further complications.

1 January 2016 in Journal of Periodontal & Implant Science
Verified
Journal Article
Open access
PDF file
Pier Paolo PoliPier Paolo Poli
Pier Paolo Poli
MBMario Beretta
Mario Beretta
GGGiovanni Battista Grossi
Giovanni Battista Grossi
CMCarlo Maiorana
Carlo Maiorana
Poli PP, et al. J Periodontal Implant Sci. 2016 Aug;46(4):266-276. https://doi.org/10.5051/jpis.2016.46.4.266