14 November 2025 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
DPDaria Pisla
Daria Pisla
VBVasile Nicolae Bulbucan
Vasile Nicolae Bulbucan
MHMihaela Hedeșiu
Mihaela Hedeșiu
Calin VaidaCalin Vaida
Calin Vaida
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
Doina PislaDoina Pisla
Doina Pisla
Background: Computer-assisted implant surgery (CAIS) aims to improve placement accuracy versus freehand drilling. We compared the three-dimensional accuracy of robot-guided CAIS (r-CAIS), dynamic navigation (d-CAIS), static-template guidance (s-CAIS), and freehand (FH) in clinical and in vitro settings. Methods: We searched PubMed/MEDLINE, Scopus, and Web of Science (1 January 2019–2025). Eligible populations were adults receiving conventional or zygomatic implants in vivo, plus validated in vitro human-jaw models using plan-versus-placement workflows; studies had to report study-level means with dispersion for ≥1 primary outcome with ≥5 implants per arm. Interventions were r-CAIS, d-CAIS, or s-CAIS; with a baseline as the freehand technique. Risk of bias used RoB 2 (RCTs), ROBINS-I (non-randomized clinical), and QUIN (in vitro). Because of heterogeneity in definitions and workflows, we performed a descriptive synthesis by modality (no meta-analysis). Registration: OSF. Results: Forty-three studies (7 RCTs, 10 non-randomized clinical, 26 in vitro) reported more than 4000 implants. Across studies, typical study-level means for global linear deviation clustered around < 1 mm (r-CAIS), ~1 mm (d-CAIS), ~1.3 mm (s-CAIS), and ~1.8 mm (FH). In clinical contexts, d-CAIS often showed slightly lower angular deviation than s-CAIS. Conclusions: CAIS improves accuracy versus freehand. d-CAIS and s-CAIS show similar linear accuracy, with d-CAIS frequently yielding slightly lower angular deviation; r-CAIS exhibits tight error clusters in our dataset, but limited comparative clinical evidence precludes superiority claims. Limitations: non-uniform registration/measurement, variable operator experience, and absence of meta-analysis.

7 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Florin CovaciuFlorin Covaciu
Florin Covaciu
NCNicolae Crisan
Nicolae Crisan
Calin VaidaCalin Vaida
Calin Vaida
IAIulia Andras
Iulia Andras
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
Doina PislaDoina Pisla
Doina Pisla
In recent years, there has been an expansion in the development of simulators that use virtual reality (VR) as a learning tool. In surgery where robots are used, VR serves as a revolutionary technology to help medical doctors train in using these robotic systems and accumulate knowledge without risk. This article presents a study in which VR is used to create a simulator designed for robotically assisted single-uniport surgery. The control of the surgical robotic system is achieved using voice commands for laparoscopic camera positioning and via a user interface developed using the Visual Studio program that connects a wristband equipped with sensors attached to the user’s hand for the manipulation of the active instruments. The software consists of the user interface and the VR application via the TCP/IP communication protocol. To study the evolution of the performance of this virtual system, 15 people were involved in the experimental evaluation of the VR simulator built for the robotic surgical system, having to complete a medically relevant task. The experimental data validated the initial solution, which will be further developed.

2 September 2022 in Machines
Verified
Journal Article
Open access
PDF file
Doina PislaDoina Pisla
Doina Pisla
IBIosif Birlescu
Iosif Birlescu
NCNicolae Crisan
Nicolae Crisan
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
IAIulia Andras
Iulia Andras
Calin VaidaCalin Vaida
Calin Vaida
The paper presents the singularity analysis and the geometric optimization of a 6-DOF (Degrees of Freedom) parallel robot for SILS (Single-Incision Laparoscopic Surgery). Based on a defined set of input/output constraint equations, the singularities of the parallel robotic system are determined and geometrically interpreted. Then, the geometric parameters (e.g., the lengths of the mechanism links) for the 6-DOF parallel robot for SILS are optimized such that the robotic system complies with an operational workspace defined in correlation with the SILS task. A numerical analysis of the singularities showed that the operational workspace is singularity free. Furthermore, numerical simulations validate the parallel robot for the next developing stages (e.g., designing and prototyping stages).

Verified
Journal Article
Open access
PDF file
Doina PislaDoina Pisla
Doina Pisla
NCNicolae Crisan
Nicolae Crisan
BGBogdan Gherman
Bogdan Gherman
IAIulia Andras
Iulia Andras
PTPaul Tucan
Paul Tucan
NHNadim Al Hajjar
Nadim Al Hajjar
Robotic-assisted single-incision laparoscopic surgery (SILS) is becoming an increasingly widespread field worldwide due to the benefits it brings to both the patient and the surgeon. The goal of this study is to develop a secure robotic solution for SILS, focusing specifically on urology, by identifying and addressing various safety concerns from an early design stage. Starting with the medical tasks and protocols, the technical specifications of the robotic system as well as potential; hazards have been identified. By employing competitive engineering design methods such as Analytic Hierarchy Process (AHP), Risk assessment, and Failure Mode and Effects Analysis (FMEA), a safe design solution is proposed. A set of experiments is conducted to validate the proposed concept, and the results strongly support the development of the experimental model. The Finite Element Analysis (FEA) method is applied to validate the mechanical architecture within a set of simulations, demonstrating the compliance of the robotic system with the proposed technical specifications and its capability to safely perform SILS procedures.

3 July 2024
Verified
Book Chapter
Closed access
PDF file
Calin VaidaCalin Vaida
Calin Vaida
BGBogdan Gherman
Bogdan Gherman
IBIosif Birlescu
Iosif Birlescu
PTPaul Tucan
Paul Tucan
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
Doina PislaDoina Pisla
Doina Pisla

5 September 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Doina PislaDoina Pisla
Doina Pisla
CPCalin Popa
Calin Popa
APAlexandru-Vasile Vasile Pusca
Alexandru-Vasile Vasile Pusca
ACAndra Ciocan
Andra Ciocan
BGBogdan Gherman
Bogdan Gherman
NHNadim Al Hajjar
Nadim Al Hajjar
This paper presents the development of the hardware and software architecture of a sixdegrees of freedom (DOF) parallel robot (PARA-SILSROB) by illustrating all the stages undertaken to achieve the experimental model of the robot. Based on the experimental model, the control architecture is also presented, which is primarily based on a master–slave control system through which the surgeon controls the robot using the master console composed of commercial peripheral components (two 3D Space Mouse devices, computer, and keyboard) integrated with the solution developed in this study and presented in this paper. The robot was developed also according to the surgical protocol and surgeon’s requirements, and for the functionality testing of the mechanical structure, two experimental stands were used. The first stand presented several surgical steps, such as manipulation, resection, and suture of experimental tissues (simulating real-life robot-assisted surgical maneuvers) using commercial instruments. The second stand presented a simulation of an esophagectomy for esophageal cancer and digestive reconstruction through a right intercostal approach. For this testing phase, the organs were created using 3D reconstruction, and their simplified models were 3D printed using PolyJet technology. Furthermore, the input trajectory generated using the master console was compared with the robot actuator’s movements and the obtained results were used for validation of the proposed robot control system.