The effective control and reduction of building energy consumption are major global focuses. The building sector is responsible for over 40% of all direct and indirect CO2 emissions. Nearly zero-energy buildings have been the subject of aims and regulations from several developed nations. An office building located in the severe cold region of China was chosen for this case study. The building was equipped with multiple NZEB technologies. Building indoor environment parameters and energy efficiency indexes were used as performance targets, and a performance-based design approach was used to optimize building design parameters. Thermal performance of the building envelope, airtightness, energy demand, and indoor thermal environment were tested according to different evaluation criteria. The total energy demand was as low as 53.93 KWh/(m2·a), and this can be attributed to the exceptional insulation of the building. In this test, the indoor thermal environment comfort was satisfactory. This study can be used as a reference for the design and evaluation of low-carbon buildings and low-energy buildings.
The “dual carbon” strategy has drawn attention to distributed PV systems for their flexibility and variability, but the rising need for direct-current (DC) loads on the load side has created additional difficulties for microgrid system upgrades. In this article, a PV-based microgrid design approach for residential buildings is suggested, working on the assumption that distributed PV systems are given top priority to handle domestic DC needs. The residential DC microgrid system’s overall design concept is first put out, and the circuit system is then concentrated to supply the main idea for the ensuing verification of the system’s viability. Secondly, the actual power generation in the selected area was clarified by testing, and then the electricity consumption of DC loads accounted for about 20.03% of the total power consumption according to the survey of 100 users. In addition, the circuit system is subjected to spectral model measurements and physical measurements to verify the operational performance of the circuit system; the feasibility of the PV microgrid system is further verified using dual testing of the PV system and the circuit system. The test results show that the proposed DC microgrid system can accurately provide the required voltage for small household DC appliances, such as 24 V, 14 V, 5 V, etc. Finally, the system economics were analyzed, and the equipment payback years were estimated. The supply and demand of PV power generation and DC appliances can be balanced via the construction of a microgrid. This study offers a fresh concept for the use of PV technology. The concept behind this research can serve as a model for the creation and application of other new energy sources.
Considering the vast areas of building rooftops and the fast development of solar utilization technologies, this paper aims to analyze the regional adaptability of solar roof utilization technologies for buildings in China. All provinces and cities in China are divided into 13 zones based on their economic development, thermal climate division, and availability of solar energy resources. Over 100 buildings are investigated, and the information of 28 buildings is analyzed to finally identify 18 typical building types. A new evaluation method is developed for both solar heating systems and solar PV. An adaptability index is developed considering the energy conservation, environment effect, and economy benefit of the systems. The developed method is used to evaluate the solar utilization technologies applied on the 18 buildings across 13 zones. The result show that the average adaptability index values for solar thermal technology and solar PV technology are 2.54 and 1.63, respectively. The solar heating system has a shorter payback time than the solar PV system for most regions of China and therefore is more favored. Recommendations on supporting policies and measures are given for policy makers with an aim to promote the utilization efficiency of building roofs. This paper provides references for the selection and application of relevant solar utilization technologies on building roofs.
With the steady annual growth of grid-connected photovoltaic (PV) power generation, the intermittent nature of this energy source has been increasingly drawing attention for its impact on grid stability. The output of photovoltaic power generation is highly influenced by weather factors and seasonal changes. The 24 solar terms are widely recognized as a reliable method for predicting weather conditions and seasonal shifts in China. Based on an analysis of the 24 solar terms, this work investigated their impact on PV power generation in China and established a correlation coefficient between PV output and solar terms. Subsequently, this paper proposed a grid connection method based on average values derived from the 24 solar terms and optimized it using a transfer learning model. The effectiveness of the proposed method was validated through a case study on a small-scale PV power station. It was validated that the proposed grid connection method increases power grid stability by 17.75%. The average grid connection method developed in this paper, which more accurately aligns with seasonal solar radiation variations, contributes to advancing grid-connected PV systems and provides a practical strategy for large-scale PV power integration.
Shared energy storage (SES) represents a transformative approach to advancing sustainable energy systems through improved resource utilization and renewable energy integration. In order to enhance the economic benefits of energy storage and prosumers, as well as to increase the consumption rate of renewable energy, this paper proposes a bilevel optimization model for multi-prosumer power complementarity based on SES. The upper level is the long-term energy storage capacity configuration optimization, aiming to minimize the investment and operational costs of energy storage. The lower level is the intra-day operation optimization for prosumers, which reduces electricity costs through peer-to-peer (P2P) transactions among prosumers and the coordinated dispatch of SES. Meanwhile, an improved Nash bargaining method is introduced to reasonably allocate the P2P transaction benefits among prosumers based on their contributions to the transaction process. The case study shows that the proposed model can reduce the SES configuration capacity by 46.3% and decrease the annual electricity costs of prosumers by 0.98% to 27.30% compared with traditional SES, and the renewable energy consumption rate has reached 100%. Through peak–valley electricity price arbitrage, the annual revenue of the SES operator increases by 71.1%, achieving a win–win situation for prosumers and SES. This article, by optimizing the storage configuration and trading mechanism to make energy storage more accessible to users, enhances the local consumption of renewable energy, reduces both users′ energy costs and the investment costs of energy storage, and thereby promotes a more sustainable, resilient, and equitable energy future.
A low-pressure environment can significantly affect human physiological mechanisms. It causes differences in human overall comfort evaluation at different pressures. Current research mainly focuses on the impact of single environmental factors on human comfort under low pressure. However, studies considering multiple environmental factors are lacking. This paper was based on the effective-function method. Thermal, luminous, and acoustic comfort experimental studies were carried out under standard atmospheric pressure and low pressure. In this study, we conducted an in-depth exploration of the human overall comfort differences under low pressure. The key findings were as follows: (1) There were differences in single environmental comfort evaluation under low pressure. (2) The influence order of unit changes in environmental factors on overall comfort was determined. Within the comfort zone, the variations of 1 °C, 100 lx, and 5 dB caused similar changes in overall comfort evaluation. When a factor deviated from the comfort zone, it became the dominant factor affecting the POCV (Predicted Overall Comfort Vote). (3) In the peak zone of overall comfort evaluation under low pressure, considering energy-saving needs, a slightly cooler environment in winter and a slightly warmer environment in summer were chosen. And the illuminance was shifted to the left of the x-coordinate. The tolerable zone became smaller, and it was easier to reach the lower limit. (4) The comfort zone nomograms for common working condition parameters were drawn. Through parameter interaction, “superior” parameters were used to compensate for “inferior” ones, thereby improving the human overall comfort evaluation. Based on these findings, this research provides a theoretical basis and data support for the design of aerospace and high-altitude environments. It offers beneficial references and ideas for the integrated development of interdisciplinary fields.