Raihan Uddin

Mr. Raihan Uddin

Electrical and Electronic Engineering, American International University-Bangladesh, Dhaka, Bangladesh
orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2024 in Energies
Verified
Journal Article
Open access
PDF file
SAShameem Ahmad
Shameem Ahmad
SHSheikh Md. Nahid Hasan
Sheikh Md. Nahid Hasan
MHMd Sajid Hossain
Md Sajid Hossain
Raihan UddinRaihan Uddin
Raihan Uddin
TATofael Ahmed
Tofael Ahmed
ASArghya Saha
Arghya Saha
Since rising worldwide energy consumption is anticipated with increasing rapid industrialization and urbanization, green energy sources have become the ineluctable choice among energy engineers, power engineers, and researchers for carbon-free and sustainable electric power generation. By integrating several energy sources, a hybrid renewable and sustainable power supply system (HRSPSS) has been created to solve the global warming problem. HRSPSS aims to develop contemporary electricity grids that benefit society, the environment, and the economy. However, there is a need for thorough assessment of these complex HRSPSSs for making the most use of renewable energy potential and carefully crafting suitable solutions. This paper provides a thorough investigation of the most effective methods for sizing, optimizing, controlling, and managing energy, as well as how to combine different renewable energy sources to create a hybrid sustainable power supply system. Information on several software simulation tools and optimization methods that have been used to support HRSPSS development, research, and planning is presented in this study. Additionally, this study covers energy management and control strategies that have been used to ensure efficient and optimal operation of HRSPSS. Furthermore, this article presents an extensive comparison among various strategies utilized in each area (sizing, optimizing, controlling, and managing energy) to provide conclusive remarks on the suitable strategies for respective applications. The outcome of this study will help various stakeholders in the energy sector to make appropriate decisions during the design, development, and implementation phases of a hybrid sustainable power supply system.

8 March 2026 in Energy Conversion and Management: X
Verified
Journal Article
Open access
KRKhandakar Sajid Rahman
Khandakar Sajid Rahman
MFMd. Abrar Hossen Faiyaz
Md. Abrar Hossen Faiyaz
NANahiduzzaman Akib
Nahiduzzaman Akib
KHK.M. Mukter Hossain
K.M. Mukter Hossain
Raihan UddinRaihan Uddin
Raihan Uddin
AHA.S. Nazmul Huda
A.S. Nazmul Huda

22 October 2026 in Environment, Development and Sustainability
Verified
Journal Article
Closed access
PDF file
Raihan UddinRaihan Uddin
Raihan Uddin
NRNadia Hossain Riya
Nadia Hossain Riya
ADAnik Datta
Anik Datta
SAShameem Ahmad
Shameem Ahmad
ABA G M Mustayen Billah
A G M Mustayen Billah
MPMd. Shahariar Parvez
Md. Shahariar Parvez

22 October 2026 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Raihan UddinRaihan Uddin
Raihan Uddin
SIShaikh Tawhidul Islam
Shaikh Tawhidul Islam
SAShameem Ahmad
Shameem Ahmad
AHA. S. Nazmul Huda
A. S. Nazmul Huda
TATofael Ahmed
Tofael Ahmed
RARayan Hamza Alsisi
Rayan Hamza Alsisi
Interconnected microgrids (IMGs) improve resilience and renewable utilization, but coordinated inter-MG power exchange, storage-constrained dispatch, and reliable multi-mode operation remain challenging. This paper proposes a new real-time Hierarchical Multi-Layer Control Strategy (HMLCS) integrating primary, secondary, and tertiary control with explicit inter-MG power sharing and constraint-aware battery dispatch. Algebraic active-power balances coordinate grid-connected, interconnected, islanded, and self-healing modes according to generation–load imbalance and neighboring support capability. Battery operation is constrained by a 20–90% state-of-charge (SoC) range, 0.6 C charge/discharge limit, 70% depth-of-discharge constraint, and SoC-dependent derating. Small-signal converter models verify closed-loop stability across the four modes, including platform latency. Implementation uses a Real-Time Digital Simulator (RTDS) with 50 µs network and 2.5 µs converter time steps. Validation covers mode transitions, unbalanced and nonlinear loading, irradiance transients, prolonged islanding, and severe fault-plus-(N − 1) outage conditions. Over the 20 s sequence, PV supplies 72.95% of load energy, with battery storage, diesel generation, and grid support contributing 14.73%, 5.14%, and 7.19%. The maximum frequency excursion is 0.260 Hz, with primary arrest in 0.25 s and full restoration in 1.71 s. Current THD is 1.604% under nominal conditions and 2.492% with 30% nonlinear loading. During 90 min of islanding, 100% of critical-load energy is served with a final SoC of 21.66%. Under the severe-disturbance sequence, self-healing provides 12.4–17.6 kW of inter-MG support without load disconnection and reduces frequency restoration time by 39.0%. Energy not served is zero and the load-energy service ratio reaches 98.37%, confirming the dynamic, power-quality, storage-aware, and resilient real-time performance of the proposed HMLCS.