rajesh kumar burra

Prof. rajesh kumar burra

GITAM University, Vizag, India
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Aswani Kumar GeraAswani Kumar Gera
Aswani Kumar Gera
RBrajesh kumar burra
rajesh kumar burra
The current scenario of the quest for microneedles (MNs) with biodegradability and biocompatibility properties is a potential research area of interest. Microneedles are considered to be robust, can penetrate the skin’s deep-seated layers, and are easy to manufacture, and their applications from the clinical perspective are still ongoing with standard escalation. This review paper focuses on some of the pivotal variants of polymeric microneedles which are specifically dissolvable and swell-based MNs. It further explores the drug dissolution kinetics and insertion behavior mechanisms with an emphasis on the need for mathematical modeling of MNs. This review further evaluates the multifarious fabrication methods, with an update on the advances in the fabrication of polymeric MNs, the choice of materials used for the fabrication, the challenges in polymeric MN fabrication, and the prospects of polymeric MNs with applications pertinent to healthcare, by exclusively focusing on the procurable literature over the last decade.

5 May 2018 in Food Analytical Methods
Verified
Journal Article
Closed access
PDF file
RSRajesh K. Srivastava
Rajesh K. Srivastava
STSekhar Talluri
Sekhar Talluri
SBSk. Khasim Beebi
Sk. Khasim Beebi
RBrajesh kumar burra
rajesh kumar burra

1 March 2022 in AIP Advances
Verified
Journal Article
Open access
PDF file
VSVASAGIRI SURESH
VASAGIRI SURESH
RBrajesh kumar burra
rajesh kumar burra
JVJyothi Vankara
Jyothi Vankara
MPM.S. Pradeep Kumar Patnaik
M.S. Pradeep Kumar Patnaik
Recently, microelectromechanical system (MEMS) cantilevers have received significant interest in the domain of Volatile Organic Compounds (VOCs). An analysis of MEMS cantilevers in VOCs is presented in this Review. It examines the different forms of sensors used to detect VOCs. It goes into the conditions that influence MEMS and the strategies used for VOC sensing. It examines research on MEMS cantilevers and other VOC sensing and detection techniques. It shows how MEMS can be used to detect VOCs. Moreover, it presents a comparative study based on the objectives, types of sensors employed, merits, and shortcomings of existing works. This Review intends to explore MEMS cantilevers in VOCs for supporting further research and applications.

1 January 2025 in AIP Advances
Verified
Journal Article
Open access
Aswani Kumar GeraAswani Kumar Gera
Aswani Kumar Gera
RBrajesh kumar burra
rajesh kumar burra
Microneedles have emerged as a promising alternative to conventional, or so-called hypodermic, needles for transdermal drug delivery. A meticulous design of microneedle geometry is crucial for balancing mechanical stability and fluid flow of drugs through these microneedles. This research paper analyzes the mechanical performance and fluid flow behavior of hollow cylindrical tapered shaped microneedles with polymethyl methacrylate, a biocompatible polymer, as material, considering its mechanical properties and also the material being widely used in biomedical applications. The finite element analysis tool is used to enhance the microneedle design by varying the outer base radius and tip radii to mitigate the von Mises stress that is exhibited during axial load and bending load conditions. In addition, microfluidic analysis is to assess the fluid flow behavior through the hollow microneedles, measuring the flow rates of fluids (water, glucose, and insulin).Simulated results reveal that an axial stress of 3.26 × 106 N/m2 and bending stress of 2.31 × 107 N/m2 were reported, which are below the yield strength of the material and satisfy the criteria for successful microneedle penetration. Flow rate analysis of water reports that 834.42 μl/min and 5396.94 μl/min and for glucose as 412 μl/min and 3648 μl/min, and that of insulin as 834 μl/min and 5244 μl/min for applied inlet pressure of 10 and 100 kPa, respectively. The flow rates reveal that water and insulin exhibit nearly identical flow rates, indicating that the proposed microneedles are capable of efficiently delivering viscous fluids.

1 January 2020 in Materials Today: Proceedings
Verified
Journal Article
Closed access
SSS. Sri Surya Srikanth
S. Sri Surya Srikanth
RBrajesh kumar burra
rajesh kumar burra
VSVASAGIRI SURESH
VASAGIRI SURESH
VJV. Jyothi
V. Jyothi
IRI. Sreenivasa Rao
I. Sreenivasa Rao
Aswani Kumar GeraAswani Kumar Gera
Aswani Kumar Gera

1 January 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
VSVASAGIRI SURESH
VASAGIRI SURESH
RBrajesh kumar burra
rajesh kumar burra
Pollution introduces harmful substances into the natural environment, resulting in environmental alterations. Industries are a major source of air pollution because of many power plants, chamber processes, cleaning operations, and material burning processes. Volatile organic compounds and other contaminants are discharged into the atmosphere. Sensor fusion technology-based air pollution has been proposed in this study to meet the national air quality criteria, and several nations have implemented emission monitoring systems. It is common knowledge that PM2.5 sensors can be found in air purifiers, in the immediate surroundings, and in everyday lives. PM2.5 particles can be more accurately detected by increasing the sensitivity to smaller particles and optimizing the flow of particles into the detecting region. The sensors’ responsiveness and sensitivity are excellent based on the testing results. A low-cost monitoring system can benefit from this technology since it may be used to give data on the levels of nitrogen, particulate matter, and inorganic nitrates.