Rakesh Pilkar

Dr. Rakesh Pilkar

Kessler Foundation, West Orange, New Jersey, USA
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2023 in npj Digital Medicine
Verified
Journal Article
Open access
PDF file
MPMatthew Patterson
Matthew Patterson
ANAdonay A. S. Nunes
Adonay A. S. Nunes
DGDawid Gerstel
Dawid Gerstel
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
TGTyler Guthrie
Tyler Guthrie
CGChristine C. Guo
Christine C. Guo
For the last 40 years, actigraphy or wearable accelerometry has provided an objective, low-burden and ecologically valid approach to assess real-world sleep and circadian patterns, contributing valuable data to epidemiological and clinical insights on sleep and sleep disorders. The proper use of wearable technology in sleep research requires validated algorithms that can derive sleep outcomes from the sensor data. Since the publication of the first automated scoring algorithm by Webster in 1982, a variety of sleep algorithms have been developed and contributed to sleep research, including many recent ones that leverage machine learning and / or deep learning approaches. However, it remains unclear how these algorithms compare to each other on the same data set and if these modern data science approaches improve the analytical validity of sleep outcomes based on wrist-worn acceleration data. This work provides a systematic evaluation across 8 state-of-the-art sleep algorithms on a common sleep data set with polysomnography (PSG) as ground truth. Despite the inclusion of recently published complex algorithms, simple regression-based and heuristic algorithms demonstrated slightly superior performance in sleep-wake classification and sleep outcome estimation. The performance of complex machine learning and deep learning models seem to suffer from poor generalization. This independent and systematic analytical validation of sleep algorithms provides key evidence on the use of wearable digital health technologies for sleep research and care.

18 December 2020 in Frontiers in Neurology
Verified
Journal Article
Open access
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
KMKamyar Momeni
Kamyar Momeni
ARArvind Ramanujam
Arvind Ramanujam
MRManikandan Ravi
Manikandan Ravi
EGErica Garbarini
Erica Garbarini
GFGail F. Forrest
Gail F. Forrest
Surface electromyography (sEMG) is a widely used technology in rehabilitation research and provides quantifiable information on the myoelectric output of a muscle. In this perspective, we discuss the barriers which have restricted the wide-spread use of sEMG in clinical rehabilitation of individuals with spinal cord injury (SCI). One of the major obstacles is integrating the time-consuming aspects of sEMG in the already demanding schedule of physical therapists, occupational therapists, and other clinicians. From the clinicians' perspective, the lack of confidence to use sEMG technology is also apparent due to their limited exposure to the sEMG technology and possibly limited mathematical foundation through educational and professional curricula. Several technical challenges include the limited technology-transfer of ever-evolving knowledge from sEMG research into the off-the-shelf EMG systems, lack of demand from the clinicians for systems with advanced features, lack of user-friendly intuitive interfaces, and the need for a multidisciplinary approach for accurate handling and interpretation of data. We also discuss the challenges in the application and interpretation of sEMG that are specific to SCI, which are characterized by non-standardized approaches in recording and interpretation of EMGs due to the physiological and structural state of the spinal cord. Addressing the current barriers will require a collaborative, interdisciplinary, and unified approach. The most relevant steps could include enhancing user-experience for students pursuing clinical education through revised curricula through sEMG-based case studies/projects, hands-on involvement in the research, and formation of a common platform for clinicians and technicians for self-education and knowledge share.

3 November 2016 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
MYMathew Yarossi
Mathew Yarossi
ARArvind Ramanujam
Arvind Ramanujam
VRVenkateswaran Rajagopalan
Venkateswaran Rajagopalan
MBMehmed Bugrahan Bayram
Mehmed Bugrahan Bayram
GFGail Forrest
Gail Forrest
The goal of this paper is to demonstrate a novel approach that combines Empirical Mode Decomposition (EMD) with Notch filtering to remove the electrical stimulation (ES) artifact from surface electromyogram (EMG) data for interpretation of muscle responses during functional electrical stimulation (FES) experiments. FES was applied to the rectus femoris (RF) muscle unilaterally of six able bodied (AB) and one individual with spinal cord injury (SCI). Each trial consisted of three repetitions of ES. We hypothesized that the EMD algorithm provides a suitable platform for decomposing the EMG signal into physically meaningful intrinsic mode functions (IMFs) which can be further used to isolate electrical stimulation (ES) artifact. A basic EMD algorithm was used to decompose the EMG signals collected during FES into IMFs for each repetition separately. IMFs most contaminated by ES were identified based on the standard deviation (SD) of each IMF. Each artifact IMF was Notch filtered to filter ES harmonics and added to remaining IMFs containing pure EMG data to get a version of a filtered EMG signal. Of all such versions of filtered signals generated from each artifact IMF, the one with maximum signal to noise ratio (SNR) was chosen as the final output. The validity of the filtered signal was assessed by quantitative metrics, 1) root mean squared error (RMSE) and signal to noise (SNR) ratio values obtained by comparing a clean EMG and EMD-Notch filtered signal from the combination of simulated ES and clean EMG and, 2) using EMG-force correlation analysis on the data collected from AB individuals. Finally, the potential applicability of this algorithm on a neurologically impaired population was shown by applying the algorithm on EMG data collected from an individual with SCI. EMD combined with Notch filtering successfully extracted the EMG signal buried under ES artifact. Filtering performance was validated by smaller RMSE values and greater SNR post filtering. The amplitude values of the filtered EMG signal were seen to be consistent for three repetitions of ES and there was no significant difference among the repetition for all subjects. For the individual with a SCI the algorithm was shown to successfully isolate the underlying bursts of muscle activations during FES. The data driven nature of EMD algorithm and its ability to act as a filter bank at different bandwidths make this method extremely suitable for dissecting ES induced EMG into IMFs. Such IMFs clearly show the presence of ES artifact at different intensities as well as pure artifact free EMG. This allows the application of Notch filters to IMFs containing ES artifact to further isolate the EMG. As a result of such stepwise approach, the extraction of EMG is achieved with minimal data loss. This study provides a unique approach to dissect and interpret the EMG signal during FES applications.

20 April 2017 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
ARArvind Ramanujam
Arvind Ramanujam
CCChristopher M. Cirnigliaro
Christopher M. Cirnigliaro
EGErica Garbarini
Erica Garbarini
PAPierre Asselin
Pierre Asselin
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
GFGail F. Forrest
Gail F. Forrest
Objective: To evaluate gait parameters and neuromuscular profiles of exoskeleton-assisted walking under Max Assist condition during a single-session for; (i) able bodied (AB) individuals walking assisted with (EXO) and without (non-EXO) a powered exoskeleton, (ii) non-ambulatory SCI individuals walking assisted with a powered exoskeleton. Design: Single-session. Setting: Motion analysis laboratory. Participants: Four AB individuals and four individuals with SCI. Interventions: Powered lower extremity exoskeleton. Outcome Measures: Temporal-spatial parameters, kinematics, walking velocity and electromyography data. Results: AB individuals in exoskeleton showed greater stance time and a significant reduction in walking velocity (P < 0.05) compared to non-EXO walking. Interestingly, when the AB individuals voluntarily assisted the exoskeleton movements, they walked with an increased velocity and lowered stance time to resemble that of slow walking. For SCI individuals, mean percent stance time was higher and walking velocity was lower compared to all AB walking conditions (P < 0.05). There was muscle activation in several lower limb muscles for SCI group. For AB individuals, there were similarities among EXO and non-EXO walking conditions however there were differences in several lower limb EMGs for phasing of muscle activation. Conclusion: The data suggests that our AB individuals experienced reduction in walking velocity and muscle activation amplitudes while walking in the exoskeleton and moreover with voluntary control there is a greater temporal-spatial response of the lower limbs. Also, there are neuromuscular phasic adaptions for both AB and SCI groups while walking in the exoskeleton that are inconsistent to non-EXO gait muscle activation.

29 August 2017 in Frontiers in Neurology
Verified
Journal Article
Open access
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
ARArvind Ramanujam
Arvind Ramanujam
KNKaren J. Nolan
Karen J. Nolan
Background: A foot drop stimulator (FDS) is a rehabilitation intervention that stimulates the common peroneal nerve to facilitate ankle dorsiflexion at the appropriate time during post-stroke hemiplegic gait. Time-frequency analysis of nonstationary surface electromyograms (EMG) and spectral variables such as instantaneous mean frequency (IMNF) can provide valuable information on the long term effects of FDS intervention in terms of changes in the motor unit (MU) recruitment during gait, secondary to improved dorsiflexion. Objective: To apply a wavelet based time-frequency analysis approach to assess the changes in neuromuscular activation of the tibialis anterior (TA), soleus (SOL) and gastrocnemius (GA) muscles after utilization of a FDS during gait post stroke. Methods: Surface EMG were collected bilaterally from the TA, SOL and GA muscles from 6 participants (142.9±103.3 months post stroke) while walking without the FDS at baseline and 6 months post FDS utilization. Continuous wavelet transform (CWT) was performed to get the averaged time-frequency distribution of band pass filtered (20-300 Hz) EMGs during multiple walking trials. IMNFs were computed during normalized gait and were averaged during the stance and swing phases. Percent changes in the energies associated with each frequency band of 25 Hz between 25 to 300 Hz were computed and compared between visits. Results: Averaged time-frequency representations of the affected TA, SOL and GA EMG show altered spectral attributes post FDS utilization during normalized gait. The mean IMNF values for the affected TA were significantly lower than the unaffected TA at baseline (p=0.026) and follow up (p=0.038) during normalized stance. The mean IMNF values significantly increased (p=0.017) for the affected GA at follow up during normalized swing. The frequency band of 250-275 Hz significantly increased in the energies post FDS utilization for all muscles. Conclusions: The application of wavelet based time-frequency analysis of EMG and outcome measures (IMNF, energy) extracted from the time-frequency distributions suggest alterations in MU recruitment strategies after the use of FDS in individuals with chronic stroke. This further establishes the efficacy of FDS as a rehabilitation intervention that may promote motor recovery in addition to treating the secondary complications of foot drop due to post-stroke hemiplegia.

7 October 2014 in NeuroRehabilitation
Verified
Journal Article
Closed access
PDF file
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
MYMathew Yarossi
Mathew Yarossi
KNKaren J. Nolan
Karen J. Nolan
Background: Functional Electrical Stimulation (FES) applied through a foot drop stimulator (FDS) is a rehabilitation intervention that can stimulate the common peroneal nerve to provide dorsiflexion at the correct timing during gait. Objective: To determine if FES applied to the peroneal nerve during walking through a FDS would effectively retrain the electromyographic temporal activation of the tibialis anterior in individuals with stroke. Methods: Surface electromyography (EMG) were collected bilaterally from the tibialis anterior (TA) while participants (n = 4) walked with and without the FDS at baseline and 4 weeks. Comparisons were made between stimulation timing and EMG activation timing to produce a burst duration similarity index (BDSI). Results: At baseline, participants displayed variable temporal activation of the TA. At 4 weeks, TA activation during walking without the FDS more closely resembled the pre-programmed FDS timing demonstrated by an increase in BDSI scores in all participants (P = 0.05). Conclusions: Continuous use of FDS during a task specific movement can re-train the neuromuscular system. After 4 weeks of utilization the FDS trained the TA to replicate the programmed temporal activation patterns. These findings begin to establish the FDS as a rehabilitation intervention that may facilitate recovery rather than just compensate for stroke related gait impairments due to foot drop.