This study aims to develop local diagnostic reference levels (DRLs) for the most common computed tomography (CT) examinations carried out around Izmir, Turkey. Five common CT examinations (head, neck, chest, abdomen–pelvis (AP), chest–abdomen–pelvis (CAP)) from four different radiology centres have been included in the study. CT dose index-volume (CTDIvol) and dose length product (DLP) values were recorded for 50 patients per exam in each centre. Third quartiles of CTDIvol and DLP values were determined as DRLs and compared with international findings. 51.3% of the patients were male and 48.7% were female, with a mean age of 57 (between 18 and 93). DRLs for CTDIvol were recorded as 70, 16, 15, 23 and 16 for head, neck, chest, AP and CAP examinations, respectively, while the corresponding DLPs were 1385, 604, 567, 998 and 1180 mGy.cm. Results are mostly comparable to the latest international data, except for the head examinations, which were observed to slightly exceed the DRLs established by other countries.
25 January 2024 in International Journal of Computational and Experimental Science and Engineering
The objective of this study was to investigate the impact of altering the board angle on critical organ doses during whole-brain irradiation. Tomography images of the head region of the rando phantom were taken at angles of 0°, 10°, 20°, 30°, and 40°. Target volume (PTV) and organ at risk (OAR) contours were created on CT images using RTOG 0933 criteria. Tomography images of the head region of the rando phantom were taken at angles of 0°, 10°, 20°, 30°, and 40°. Target volume (PTV) and critical organ contours were created on CT images using RTOG 0933 criteria. During this comparative study, we aimed to achieve a standardized dose distribution in the PTV. We evaluated the doses received by D2 (minimum dose received by 2% of the target volume), D98 (minimum dose received by 98% of the target volume), D50 (dose received by 50% of the target volume), and organs at risk (OAR) in the PTV using CT scans taken at different angles. Additionally, we compared the homogeneity index (HI), conformity index (CI), and treatment time (MU) values. This method aimed to decrease the dose of the OAR region near the target volume, specifically the hippocampus. Our findings indicate that a board angle of 300 offers the greatest protection in terms of critical organ doses.
1 March 2023 in Polish Journal of Medical Physics And Engineering
Introduction: It is necessary to have special experience to perform the Monte Carlo calculation, commonly used in medical physics and accepted as the gold standard. In this study, we developed software to teach basic steps to medical physicists who were inexperienced in the medical linear accelerator Monte Carlo simulation. Material and methods: For the design interface, a software called GamosLinacGUI was developed using Gnome Builder, Python, and GTK. The user, who wants to learn the basics of GAMOS and simulate a linear accelerator, can enter the values in the software, select some options and quickly create geometry and physics files. Results: For proof that the software generates the correct inputs for GAMOS simulation in the same conditions for the measurements and calculations. Required files for GAMOS have been created and tested and run the simulation accordingly. This software was tested with Centos Linux. Conclusions: GamosLinacGUI has been successfully developed, which creates the geometry and physics files required for the simulation with GAMOS as a training and learning tool.
29 September 2025 in Dokuz Eylül Üniversitesi Mühendislik Fakültesi Fen ve Mühendislik Dergisi
Bismuth and Lead are commonly used for radiation shielding to mitigate risks such as radiation damage and cancer. However, these materials are costly and impractical for certain applications. This study aims to explore the attenuation properties of various elements and composites using Monte Carlo simulations to develop improved radiation shielding materials. GAMOS software was employed to simulate materials with thicknesses ranging from 0.1 to 2.0 mm and x-ray energies between 10 and 150 keV. Initial simulations focused on validating bismuth and lead by calculating their mass attenuation coefficients, which matched NIST (National Institute of Standards and Technology) values within a 2% margin of difference. After verification, the study simulated various shielding materials incorporating metals and rare earth elements. Among these, four composites with rare earth elements demonstrating the highest mass attenuation coefficients were selected. These composites exhibited superior absorption in the 50–80 keV energy range compared to bismuth and lead.
Ekran film radyografisinde ışınlama parametrelerinin çok düşük ya da yüksek seçilmesi ve buna bağlı olarak filmde kararma derecelerinin düşük ya da yüksek olması film atık/tekrar oranlarının artmasına neden olmaktadır. Dijital röntgen cihazlarında ise dinamik aralığın geniş olması nedeniyle bu risklerin ortadan kalktığı düşünülse bile çok düşük veya yüksek ışınlamalar görüntü kalitesi ve hasta dozlarını etkilemektedir. Üretici firmalar bir dijital radyografi yöntemi olan bilgisayarlı radyografi cihazlarında aşırı doza karşın bir güvenlik önlemi olarak ışınlama indeksi (EI) değeri sunmaktadırlar ve bu bir hasta doz göstergesi olmayıp radyografi elde ediminde ışınlamanın bir ölçüsü olarak tanımlanmaktadır. Dijital röntgen cihazlarında radyasyon doz değerlendirmelerini yapabilmek amacıyla ışınlama indeksi değerini kontrol etmek hastaya verilen dozları takip etmek için önem taşımaktadır. Bu nedenle, bu çalışmada Agfa CR sistemlerinde ışınlama indeksi değeri olarak tanımlanan IgM’nin tutarlılığının değerlendirilmesi amaçlanmıştır. Bu amaçla, farklı model 16 Agfa CR cihazının doz çıkışları ile ilgili kalite kontrol testleri yapılarak cihazın verdiği ve hesaplanan IgM değerleri belirlenmiş ve karşılaştırılmıştır. Bu çalışma sonucunda cihazların tüp çıkış değerleri ve IgM değerleri kabul sınırlarında bulunmuş olup, cihazlar arasındaki verilerdeki dalgalanmaların cihazın yaşı ya da x ışını tüpü ömrü ile ilişkili olduğu düşünülmüştür. Agfa CR cihazlarının IgM verilerinin doğru ve güvenle kullanılabilmesi, hasta doz takibi ve hasta dozlarının tahmininde önemli bir rol oynamaktadır.
About Me
Secondary dose check calculations with Monte Carlo simulation.
Secondary dose check calculations with Monte Carlo simulation.