Renato Caravellos Glória

Dr. Renato Caravellos Glória

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Clinical Orthopaedics and Trauma
Verified
Journal Article
Closed access
Vincenzo GiordanoVincenzo Giordano
Vincenzo Giordano
MGMarcos Giordano
Marcos Giordano
Renato Caravellos GlóriaRenato Caravellos Glória
Renato Caravellos Glória
FSFelipe Serrão de Souza
Felipe Serrão de Souza
PTPaulo di Tullio
Paulo di Tullio
HKHilton Augusto Koch
Hilton Augusto Koch

7 January 2025 in European Journal of Orthopaedic Surgery & Traumatology
Verified
Journal Article
Closed access
PDF file
PJPaulo Roberto Hernandes Júnior
Paulo Roberto Hernandes Júnior
TGThiago Alves Garcia
Thiago Alves Garcia
Renato Caravellos GlóriaRenato Caravellos Glória
Renato Caravellos Glória
GWGUSTAVO Waldolato WALDOLATO
GUSTAVO Waldolato WALDOLATO
AAAndré Luis Lugnani de Andrade
André Luis Lugnani de Andrade
WBWilliam Dias Belangero
William Dias Belangero

1 July 2022 in Orthopedics
Verified
Journal Article
Closed access
VGVincenzo Giordano
Vincenzo Giordano
Renato Caravellos GlóriaRenato Caravellos Glória
Renato Caravellos Glória
TSTalles Araújo dos Santos
Talles Araújo dos Santos
HKHilton A. Koch
Hilton A. Koch
PGPeter V. Giannoudis
Peter V. Giannoudis
Articular fractures of the distal humerus in adults are challenging fractures requiring adequate surgical exposure for optimum reconstruction. Most commonly, an articular osteotomy of the olecranon is performed, but complications have been reported related to both creating and repairing the articular osteotomy. We describe the use of an extra-articular olecranon osteotomy for approaching articular fractures of the distal humerus. We highlight the surgical steps required to obtain adequate exposure facilitating anatomical reduction, stable fixation, and early range of motion of the elbow joint. This technique can be added to the surgeon's armamentarium for the management of these complex injuries. [ Orthopedics . 2022;45(4):e220–e225.]

27 February 2026 in Medicina
Verified
Journal Article
Open access
PDF file
Renato Caravellos GlóriaRenato Caravellos Glória
Renato Caravellos Glória
PLPedro José Labronici
Pedro José Labronici
AFANDERSON FREITAS
ANDERSON FREITAS
Vincenzo GiordanoVincenzo Giordano
Vincenzo Giordano
Background and Objectives: The management of periprosthetic tibial fractures distal to revision Total Knee Arthroplasty (TKA) presents a biomechanical challenge, often requiring extramedullary locking plates when long stems preclude nailing. While in femoral fractures the gap between the stem and plate is a well-documented stress riser, requiring implant overlap to prevent an inter-implant fracture, this specific biomechanical scenario has not been studied in the tibia, and it remains unclear if the femoral dogma of mandatory overlap applies to the straight, centrically loaded tibial anatomy. This study utilized Finite Element Analysis (FEA) to evaluate stress distribution in the tibial inter-implant gap. Materials and Methods: A comparative FEA was performed using a validated standardized tibia model simulating a healed distal fracture. Two cemented revision TKA constructs (50 mm and 80 mm stems) were modeled. These were paired with medial locking plates of varying lengths (10, 12, and 14 holes) to create different inter-implant distances. Eight distinct configurations, including non-plated controls, were subjected to physiological axial compression and three-point bending. Outcome measures included von Mises stress and total displacement. Results: The analysis revealed no significant stress concentration in the bone within the inter-implant zone across all plated models, regardless of the gap size. Instead, the addition of plates universally reduced bone stress compared to controls, effectively transferring load to the fixation hardware. Peak stresses were consistently observed in the proximal locking screws rather than the bone gap. The longest plates (14 holes) offered superior construct rigidity and stress distribution. Conclusions: Under the conditions evaluated in this preclinical finite element model, the tibia does not exhibit a biomechanical requirement for implant overlap to prevent stress risers. Our findings suggest that extramedullary fixation with the longest available anatomical locking plate represents a biomechanically plausible strategy for these fractures, even if an inter-implant gap remains.