Renke Liu

Dr. Renke Liu

Pure and Applied Physics, Waseda University, Tokyo, Japan
orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in Biomimetics
Verified
Journal Article
Open access
PDF file
RLRenke Liu
Renke Liu
HZHuakai Zheng
Huakai Zheng
MHMaroš Hliboký
Maroš Hliboký
HEHiroki ENDO
Hiroki ENDO
SZSHUYAO ZHANG
SHUYAO ZHANG
HSHideyuki Sawada
Hideyuki Sawada
This research introduces an advanced robotic finger designed for future generalist robots, closely mimicking the natural structure of the human finger. The incorporation of rarely discussed anatomical structures, including tendon sheath, ligaments, and palmar plates, combined with the usage of anatomically proven 3D models of the finger, give rise to the highly accurate replication of human-like soft mechanical fingers. Benefiting from the accurate anatomy of muscle insertions with the utilization of Shape Memory Alloy (SMA) wires’ muscle-like actuation properties, the bonding in-between the flexor tendons and extensor tendons allows for the realization of the central and lateral band of the finger anatomy. Evaluated using the computer vision method, the proposed robotic finger demonstrates a range of motion (ROM) equivalent to 113%, 87% and 88% of the human dynamic ROM for the DIP, PIP and MCP joints, respectively. The proposed finger possesses a soft nature when relaxed and becomes firm when activated, pioneering a new approach in biomimetic robot design and offering a unique contribution to the future of generalist humanoid robots.

7 November 2023 in Actuators
Verified
Journal Article
Open access
PDF file
RLRenke Liu
Renke Liu
SZSHUYAO ZHANG
SHUYAO ZHANG
YBYusuke BABA
Yusuke BABA
HSHideyuki Sawada
Hideyuki Sawada
Shape memory alloys (SMAs) exhibit a unique property that undergoes deformation in response to temperature variation. This characteristic can be utilized via the application of a filiform SMA wire to tendon-driven robotic actuators for biomimetic joint movements. However, due to the inefficiencies in heat dissipation, conventional SMA tendon-driven actuators are characterized by their lower relaxation speeds than other actuators. This paper proposes a novel cooling design for an SMA tendon-driven actuator using thin-fin heat sinks based on a multi-layer wrapped SMA tendon design. In addition, the electric circuit and the controller are refined. Prototype devices are constructed to validate the performance of SMA-based actuators under PID control. The results indicate that the proposed design exceeds previous models in terms of relaxation performance by up to 5.8 times while also being able to stabilize at a target angle within 0.5 s under control.

18 November 2024 in Actuators
Verified
Journal Article
Open access
PDF file
TNTomohiro Nozawa
Tomohiro Nozawa
RLRenke Liu
Renke Liu
SSSusumu S Sawada
Susumu S Sawada
In this paper, we propose a novel tactile display that can present vibration patterns and thermal stimuli simultaneously. The vibration actuator employs a shape memory alloy (SMA) wire to generate micro-vibration with a frequency control of up to 300 Hz. The micro-vibration is conducted to a tactile pin for amplifying the vibration, to be sufficiently recognized by a user. A thermal stimulation unit, on the other hand, consists of four Peltier elements with heatsinks for heat radiation. Four vibration actuators and a thermal unit are arranged in a flat plane with a size of 20 mm × 20 mm, on which a user places the tip of an index finger to feel the presented vibratory stimuli under different temperature conditions. We conducted an experiment by employing nine subjects to evaluate the performance of the proposed tactile display and also to investigate the effects of temperature on recognizing tactile sensation. The results demonstrated that the proposed device was feasible for the quantitative diagnosis of tactile sensation. In addition, we verified that the sensitivity of tactile sensation decreased with colder stimuli.

8 July 2026 in Actuators
Verified
Journal Article
Open access
PDF file
YKYuto Kawahara
Yuto Kawahara
RLRenke Liu
Renke Liu
HSHideyuki Sawada
Hideyuki Sawada
Haptic feedback has attracted significant attention in virtual reality (VR), augmented reality (AR), and teleoperation because it can provide rich tactile information of an object through skin without increasing visual load. Among the many tactile presentation methods, vibration is the most widely used, and numerous vibration actuators have been incorporated into tactile displays. For directional control, attempts have been made to generate directional acceleration within a two-dimensional plane using a single device, but the reported device produces a single-shot impact rather than continuous vibration and offers limited control of the acceleration magnitude. To address this, we focus on a shape-memory alloy (SMA) wire. The wire contracts when heated by an applied current and returns to its original length when the current is stopped. Such repeated contraction and recovery generate vibration in synchronization with a pulse current. This paper proposes a vibrator that suspends a moving part with four SMA wires to generate two-dimensional directional acceleration with a single compact device. Through driving experiments, we show that the device generates acceleration aligned with the axis of each of eight target directions spaced at 45° intervals, and that the magnitude of the acceleration can be adjusted through the duty ratio at a fixed driving frequency. The perceptual evaluation of the presented direction is left for future work.

5 June 2026 in Machines
Verified
Journal Article
Open access
PDF file
SASota Amano
Sota Amano
RLRenke Liu
Renke Liu
HSHideyuki Sawada
Hideyuki Sawada
This paper introduces a novel diameter-varying spherical robot that locomotes by local shell deformation and rolling. The robot is based on a dodecahedron-inspired shell structure equipped with 12 movable outer modules driven by a central screw-driven lifting mechanism. Unlike conventional spherical robots that mainly use the internal mass shift or internal rotating units inside a rigid shell, the proposed robot changes its locally deforming geometry by extending selected outer modules. To investigate the resulting rolling behavior, a physical simulation environment was constructed in Unreal Engine coupled with an external Python controller through OSC-based communication. The physical simulation preserves the essential geometry of the robotic body including control circuits situated in the core part and provides a repeatable platform for observing contact-driven rolling locomotion under time-managed operation. As the initial operational observation of the diameter-varying spherical robot, hardware observations were conducted to examine whether the same deformation-induced rolling principle could be physically realized in the fabricated robot. The paper presents the design of the spherical robot, the locomotion principle, physical simulation environment and the rolling simulation, and the experimental verification of the fabricated robot.

8 May 2025 in Biomimetics
Verified
Journal Article
Open access
PDF file
YSYuma Shiokawa
Yuma Shiokawa
RLRenke Liu
Renke Liu
HSHideyuki Sawada
Hideyuki Sawada
Insect flight mechanisms are highly efficient and involve complex hinge structures that facilitate amplified wing movement through thoracic deformation. However, in the field of flapping-wing robots, the replication of thoracic skeletal structures has received little attention. In this study, we propose and compare two different hinge models inspired by insect flight: an elastic hinge model (EHM) and an axle hinge model (AHM). Both models were fabricated using 3D printing technology using PLA material. The EHM incorporates flexible structures in both the hinge and lateral scutum regions, allowing for deformation-driven wing motion. In contrast, the AHM employs metal pins in the hinge region to reproduce joint-like articulation, while still permitting elastic deformation in the lateral scutum. To evaluate their performance, we employed an SMA actuator to generate flapping motion, and measured the wing displacement, flapping frequency, and exoskeletal deformation. The experimental results demonstrate that the EHM achieves wing flapping through overall structural flexibility, whereas the AHM provides more defined hinge motion while maintaining exoskeletal elasticity. These findings contribute to our understanding of the role of hinge mechanics in bioinspired flapping-wing robots. Future research will focus on optimizing these mechanisms for higher frequency operation, weight reduction, and better energy efficiency.