Rita El Feghali

Dr. Rita El Feghali

University of Genoa, Genoa, Liguria, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Journal of Endodontics
Verified
Journal Article
Closed access
BGBarbara Skrlj Golob
Barbara Skrlj Golob
GOGiovanni Olivi
Giovanni Olivi
MVMirijam Vrabec
Mirijam Vrabec
Rita El FeghaliRita El Feghali
Rita El Feghali
SPSteven Parker
Steven Parker
SBStefano Benedicenti
Stefano Benedicenti

1 April 2019 in Photobiomodulation, Photomedicine, and Laser Surgery
Verified
Journal Article
Closed access
JDJessica Dagher
Jessica Dagher
Rita El FeghaliRita El Feghali
Rita El Feghali
SPSteven Parker
Steven Parker
SBStefano Benedicenti
Stefano Benedicenti
CZCarla Zogheib
Carla Zogheib
Objective: The aim of this randomized clinical study was to evaluate the effect of laser-activated irrigation using a photon-induced photoacoustic streaming (PIPS) technique on postoperative pain following completion of root canal obturation. Methods: Fifty-six patients were enrolled in this randomized clinical trial. Fifty-six healthy premolars or molars with asymptomatic irreversible pulpitis, symptomatic irreversible pulpitis, or symptomatic pulpal necrosis, with or without apical periodontitis, were mechanically prepared for endodontic treatment and divided into two groups. Patients were randomly allocated to treatment groups. In the positive control group G1, the final irrigation with 2 cc of 5.25% sodium hypochlorite (NaOCl) was achieved using a 27G needle, introduced into the canal to a distance of 5 mm from the predetermined working length. In the experimental group G2, the root canals were irrigated with 17% ethyldiamine tetric acid (EDTA) and 5.25% NaOCl following the PIPS protocol, using an Er:YAG 2940 nm laser (LightWalker ATS®; Fotona, Slovenia) with a 600 μm diameter tip and operating parameters of 20 mJ per pulse, 15 Hz frequency, 0.3 W average power, and a 50-μs pulse duration. Postoperatively, the patients were advised to take a minor analgesic (ibuprofen 400 mg) in the event of pain perception. Postoperative pain levels were assessed after 24, 48, and 72 h and 7 days through the use of a Visual Analogue Scale questionnaire, completed by each patient. Data were analyzed using Kolmogorov–Smirnov, Fisher Exact, Chi square, Mann–Whitney test, and Friedman's test. The level of significance was set at α = 0.05. Results: There was no significant difference between the laser-irradiated group and the control group (p < 0.5). Laser activation of irrigating solutions did not increase postoperative pain. Conclusions: The outcome of this investigation indicated that PIPS was as effective as conventional irrigation in relation to postoperative pain, making this activation technique interesting to use for supplementary root canal disinfection.

3 August 2021 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
SBShivani Bellal
Shivani Bellal
Rita El FeghaliRita El Feghali
Rita El Feghali
AMAbha Mehta
Abha Mehta
ANArunkumar Namachivayam
Arunkumar Namachivayam
SBStefano Benedicenti
Stefano Benedicenti

26 July 2022 in Photonics
Verified
Journal Article
Open access
PDF file
Rita El FeghaliRita El Feghali
Rita El Feghali
KTKaren Tatarian
Karen Tatarian
CZCarla Zogheib
Carla Zogheib
SBStefano Benedicenti
Stefano Benedicenti
CPClaudio Pasquale
Claudio Pasquale
Andrea AmaroliAndrea Amaroli
Andrea Amaroli
The periapical local anesthetic injection may be associated with fear of needles and pain administration. Dental topical anesthetic agents can help to reduce pain perception; however, adverse events can occur. To investigate the efficacy of 1064-nm photobiomodualtion (PBM) in inducing mucosal anesthesia delivered with a flat-top hand-piece compared to 20% Benzocaine topical anesthetic gel, sixty healthy patients were randomly allocated (1:1) to either 20% benzocaine topical gel + placebo laser (T group) or PBM + placebo gel (L group). The 1064-nm Nd:YAG laser was employed and is associated with a novel flat-top hand piece. The applied operational parameters were 0.5 W, 10 Hz, 100 µs pulse width, and 30 J/cm2 for one-minute single application time. The enrolled subjects were asked to assess pain intensity at the time of anesthetic injection with a Visual Analog Scale. Taking into consideration taste, undesirable numbness, and overall satisfaction, the patients were asked to rate their experiences according to a verbal rating scale. Statistical analysis showed no statistically significant difference between the T and L Groups for pain ratings (p = 0.0596). The L Group displayed significantly higher ratings than T Group for taste, undesirable numbness, and overall satisfaction (p < 0.001). The 1064-nm PBM delivered by flat-top hand piece is effective in inducing mucosal anesthesia, eliminating the adverse side-effects of the conventional topical anesthetic gel.

16 June 2022 in Photonics
Verified
Journal Article
Open access
PDF file
JAJumana Alsarhan
Jumana Alsarhan
Rita El FeghaliRita El Feghali
Rita El Feghali
TAThaer Alkhudari
Thaer Alkhudari
SBStefano Benedicenti
Stefano Benedicenti
CPClaudio Pasquale
Claudio Pasquale
This study aims to point out the correlation between photobiomodulation (PBM) targets and effects and management of temporomandibular disorders (TMDs) pain using diode lasers with infrared wavelengths ranging from 780 up to 980 nanometers (nm). A systematic search of multiple electronic databases was done to identify the clinical trials published between 1st January 2010 and 18th December 2021. The included studies were limited to human subjects who had TMD pain, involving two genders with age > 18 years, and were treated with PBM using a diode laser (780–980 nm) as a non-pharmacological therapy to decrease the intensity of the pain associated to TMDs. The risk of bias for included studies was assessed using the Cochrane RoB tool (for randomized studies). The methodologic quality was rated using the Delphi list. The findings suggest that PBM is an effective tool in alleviating TMDs’ pain and increasing the range of movement in patients with Axis 1 of TMDs. However, TMDs’ pain related to underlying pathology cannot be solely treated by PBM. The causative factors must be treated first. Studies displaying the highest quality Delphi score may represent a suggested PBM therapy protocol to follow for TMDs pain management.

13 July 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MKMelissa El Khoury
Melissa El Khoury
RARoula Akl
Roula Akl
Rita El FeghaliRita El Feghali
Rita El Feghali
SGStephanie Ghoubril
Stephanie Ghoubril
JGJoseph Ghoubril
Joseph Ghoubril
SBStefano Benedicenti
Stefano Benedicenti
Background: In orthodontic treatment, mini-screws can provide maximum anchorage conditions. If the miniscrew stability is compromised, this could jeopardize the outcomes of the orthodontic treatment or biomechanics. Photobiomodulation therapy (PBMt) is beneficial for biological tissues since it promotes wound healing with its anti-inflammatory and osteo-stimulatory properties. Objectives: The purpose of this study was to evaluate the effects of 810-nm Diode PBMt on the stability of orthodontic mini-screws for three months. Trial Design: Parallel, allocation ratio 1:1. Methods: Using a split-mouth technique, a total of 40 mini-screws were randomly allocated (1:1) to either a placebo laser application (P group) or a laser PBMt (L group). An 810-nm diode laser irradiation of 1 W output power, operating in continuous wave mode for 50 s, was applied in a sweeping movement at a 22 mm distance from the mini-screws. The allocated mini-screws first received PBMt at baseline, then every other day for five days, and then at each orthodontic visit (every three weeks) for a period of three months. At each visit, the stability of the mini-screws was measured by the Osstell Implant Stability Quotient (Osstell ISQ) at three points: lower, upper, and distal to the mini-screw. Results: The lower, upper, and distal ISQ values of irradiated and non-irradiated mini-screws significantly decreased at each point over time (p < 0.001). No significant difference was found in the global ISQ values between the laser and the placebo group (p > 0.05). Conclusion: PBM did not significantly increase the stability of orthodontic mini-screws over a period of three months. Trial Registration: Protocol was approved by the Research Ethics Committee of the Faculty of Dental Medicine of Saint Joseph University, Beirut, Lebanon University (#USJ/2019/161).