Raphael Nunes

Prof. Dr. Raphael Nunes

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018 in Journal of Cleaner Production
Verified
Journal Article
Closed access
AKA. Khosravi
A. Khosravi
Raphael NunesRaphael Nunes
Raphael Nunes
Mamdouh El Haj AssadMamdouh El Haj Assad
Mamdouh El Haj Assad
LML. Machado
L. Machado

1 August 2019 in International Journal of Refrigeration
Verified
Journal Article
Closed access
Juan Jose Garcia PabonJuan Jose Garcia Pabon
Juan Jose Garcia Pabon
AKAli Khosravi
Ali Khosravi
Raphael NunesRaphael Nunes
Raphael Nunes
LMLuiz Machado
Luiz Machado

21 March 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
HDHélio Augusto Goulart Diniz
Hélio Augusto Goulart Diniz
TPTiago Freitas Paulino
Tiago Freitas Paulino
Juan Jose Garcia PabonJuan Jose Garcia Pabon
Juan Jose Garcia Pabon
AMANTONIO AUGUSTO TORRES MAIA
ANTONIO AUGUSTO TORRES MAIA
Raphael NunesRaphael Nunes
Raphael Nunes
This paper presents a distributed mathematical model for a carbon dioxide direct expansion solar-assisted heat pump used to heat bath water. The main components are a gas cooler, a needle valve, an evaporator/collector, and a compressor. To develop the heat exchange models, mass, energy, and momentum balances were used. The model was validated for transient as well as steady state conditions using experimental data. A reasonably good agreement was observed between the predicted temperatures and experimental data. The simulations showed that the time step required to demonstrate the behavior of the heat pump in the transient regime is greater than the time step required for the steady state. The results obtained with the mathematical model revealed that a reduction in the water mass flow rate results in an increase in the water outlet temperature. In addition, when the carbon dioxide mass flow rate is reduced, the compressor inlet and outlet temperatures increase as well as the water outlet temperature.

29 January 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
SRSabrina N. Rabelo
Sabrina N. Rabelo
TPTiago F. Paulino
Tiago F. Paulino
CSCarla P.M. Soares
Carla P.M. Soares
DDDuarte Moreira Duarte
Duarte Moreira Duarte
LMLuiz Machado
Luiz Machado
Raphael NunesRaphael Nunes
Raphael Nunes

1 November 2020 in Applied Thermal Engineering
Verified
Journal Article
Closed access
TRThiago Torres Martins Rocha
Thiago Torres Martins Rocha
CPCleison Henrique de Paula
Cleison Henrique de Paula
JPJuan Jose Garcia Pabon
Juan Jose Garcia Pabon
TPTiago de Freitas Paulino
Tiago de Freitas Paulino
Raphael NunesRaphael Nunes
Raphael Nunes

1 May 2018 in Journal of Renewable and Sustainable Energy
Verified
Journal Article
Closed access
PDF file
AVAna Carolina O. Veloso
Ana Carolina O. Veloso
Raphael NunesRaphael Nunes
Raphael Nunes
RKRicardo N. N. Koury
Ricardo N. N. Koury
RSRoberta V. G. Souza
Roberta V. G. Souza
Technical literature shows that there is a performance gap between a simulated design and the actual building performance, especially given the differences between the post-occupation routines and those provided in the design phase. This paper aims to analyze the differences between the electric energy consumption prediction of a call center building located in Belo Horizonte, Brazil, using (a) a schedule based on routines provided by the air conditioning designer made in order to establish the system loads and to define the system equipment and (b) a schedule based in the employee's routines provided by the owners of the building. First, the simulation results were compared to the mean measured building energy consumption and, differently from the first schedule, when the second schedule was used, a Normalized Mean Bias Error (NMBE) of 5% was met which is considered a prediction acceptable by the ASHRAE Guideline 14-2002 [Measurement of Energy and Demand Savings (American Society of Heating, Refrigerating and Air-conditioning Engineers, 2002)]. Afterwards, it was verified how the two occupation schedules influenced the building classification according to the Brazilian Governmental Building Energy Efficiency Labeling. In this case, the two different schedules resulted in a difference in electric energy consumption of 10.9%, leading to a difference of one level in the classification. This fact clearly demonstrates the importance of a correct definition of occupation and equipment usage in the energy performance prediction of a building.