Rodolfo Labernarda

Dr. Rodolfo Labernarda

Department of Civil Engineering, University of Calabria, Rende, Italy
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


25 September 2020 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
Fabio MazzaFabio Mazza
Fabio Mazza
Rodolfo LabernardaRodolfo Labernarda
Rodolfo Labernarda
A limited gap between closely spaced structural parts may induce internal pounding in seismically isolated structures, because of notable displacement at the level of the isolation system under severe earthquakes. A gap between a fixed-base elevator shaft and the surrounding building is presented here with reference to a reinforced concrete building located in the Sicilian town of Augusta. The building, comprising a basement and three storeys above the ground level, is seismically isolated at the top of rigid columns in the basement with a hybrid isolation system including elastomeric and sliding bearings, while a steel framed elevator shaft crosses the isolation level. Despite the gap, internal pounding may occur at all levels of the superstructure when the elevator with maximum load stops at the upper floors. To reduce structural pounding effects, a magnetic damped link (MDL) between adjacent corners of the elevator and the surrounding building is proposed. This is obtained as an in parallel combination of an eddy current damped link (ECDL) and an elastic helicoidal spring, and occupies less space than traditional passive dampers and transmits considerably less forces compared to a rigid link configuration. Specifically, an ECDL consists of an outer cylindrical copper tube, as conductor, and an inner tube, equipped with an array of axially magnetized and ring-shaped permanent magnets separated by iron pole pieces, as mover. The relative motion between conductor and magnets, during seismic loading, induces an eddy current producing electromagnetic damping. Given that viscoelastic linear behaviour can be hypothesized for the MDL, a simplified iterative design procedure of the ECDL is proposed, with optimization of the thickness and radius of the magnets, thereby enhancing magnetic flux and energy dissipation. The directionality of the near-fault ground motions is investigated through nonlinear seismic analysis, comparing no connection with four configurations of the interconnection: i.e., flexible and rigid elastic links, viscous and magnetic damped links.

15 May 2024 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Open access
Fabio MazzaFabio Mazza
Fabio Mazza
ADAngelo Donnici
Angelo Donnici
Rodolfo LabernardaRodolfo Labernarda
Rodolfo Labernarda
Base‐isolated hospitals are frequently preferred to fixed‐base ones because of their improved seismic structural performance. Despite this, the question remains open on the advisability of using this modern seismic protection technology in preference to other conventional solutions, on the grounds of a holistic approach based on limiting non‐structural damage as well as continuity of service to the community in the aftermath of an earthquake. Two full‐scale four‐storey (fixed‐base) and three‐storey (base‐isolated) hospital buildings have been recently built and subjected to three‐dimensional shaking table tests at the National Research Institute for Earth Science and Disaster Prevention (Japan), with particular attention to evaluating and classifying functionality of non‐structural components and vital medical equipment. A two‐phase experimental campaign was carried out considering two earthquakes scaled at different intensity levels and applied along the horizontal and vertical directions. The current study aims to provide results of a numerical structural and non‐structural blind prediction of these hospital settings. A homemade numerical code is developed to account for lumped plasticity modelling of steel frame members and variability of the friction coefficient of spherical sliding bearings. Moreover, three non‐structural components are modelled in the fixed‐base structure: that is, elastic single degree of freedom systems representing two tanks filled with sand at the top floor; elastic beam elements for piping at the third floor; five‐element macro‐model for the in‐plane‐out‐of‐plane nonlinear response of partition walls at the first floor. The identification of predominant vibration periods of the fixed‐base structure is carried out using a homemade numerical code based on the continuous wavelet transforms in combination with the complex Morlet wavelet. Finally, the sliding and rocking motion of three items of medical equipment (i.e., incubator at third floor, dialysis machine at second floor and surgical bed at first floor) are analysed by means of a homemade numerical code, considering acceleration time histories of selected structural nodes of the fixed‐base structure.

18 January 2021 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
Fabio MazzaFabio Mazza
Fabio Mazza
Rodolfo LabernardaRodolfo Labernarda
Rodolfo Labernarda
Pounding among internal structural parts of seismically isolated structures may happen because of high horizontal deformability of the isolation system. To study this poorly investigated issue, a reinforced concrete (r.c.) framed structure built in Sicily (Italy) is considered, with a hybrid isolation system combining elastomeric and sliding bearings. The building consists of four-storey, basement included, with the steel-framed structure of the elevator crossing the isolation level. Two structural configurations are considered for the elevator shaft: base-isolated, with rigid link to the surrounding building; fixed-base, with a seismic gap to prevent internal pounding. Effectiveness of the Italian and European code provisions, based on setting up adequate separation distance, is assessed. Four modelling assumptions of the highly nonlinear behavior of elastomeric bearings are examined and a mathematical model is calibrated on experimental data. Nonlinear seismic analysis of the test structure is carried out considering eight cases, which are obtained combining four position of the elevator (i.e., at the basement and upper three levels) and two load conditions (i.e., elevator empty and with maximum load). Torsional effects induced by an asymmetric position of the elevator shaft are quantified by means of polar plots, representing the critical envelope for all excitation angles of bi-directional earthquakes.

1 January 2018 in Procedia Structural Integrity
Verified
Journal Article
Open access
Fabio MazzaFabio Mazza
Fabio Mazza
Rodolfo LabernardaRodolfo Labernarda
Rodolfo Labernarda