Rodrigo Rozenblit Tiferes

Dr. Rodrigo Rozenblit Tiferes

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2024 in IEEE Open Access Journal of Power and Energy
Verified
Journal Article
Open access
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
GJGiovanni Manassero Junior
Giovanni Manassero Junior
EPEduardo Lorenzetti Pellini
Eduardo Lorenzetti Pellini
SSSilvio Di Santo
Silvio Di Santo
This paper presents a novel pilot protection algorithm for alternating current (ac) transmission lines that relies on biweight midcorrelation (BWMC) coefficients between the terminals’ currents. The proposed solution was compared with recent and similar literature alternatives, and the results indicate that it is both effective in detecting faults of any type and that, as it is median-based, unlike the techniques used so far, the BWMC-based algorithm may be advantageous over existing methods as it presents higher robustness to not incorrectly trip on external faults, mainly under the critical conditions of CT saturation, noisy measurements, and sample misalignment, typically associated with outliers. The algorithm also proved effective against simultaneous multi-faults, weak infeed, power swing, multiple cases on different lines, and faults with time-varying transition resistance. The BWMC-based solution was finally experimentally tested in real-time with a hardware-in-the-loop system containing a CMC-256 set, an IEC 61850-based IED that embeds the algorithm’s logic, and current measurements recorded during actual faults on existing 500 kV lines from the Brazilian interconnected power system. All analyses indicate that this new algorithm can be a rapid, reliable, and robust solution.

1 June 2022 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
PDF file
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
GJGiovanni Manassero Junior
Giovanni Manassero Junior
This paper presents a distance protection method based on estimating the resistances and inductances seen by the relay using a least-squares (LS) approach combined with the application of Bayesian inference (BI) to determine fault probabilities in the protected zone over time. The use of BI in the presented algorithm increases the security and reliability of the LS-based line protection approach, which, although fast, may yield impedance estimates with numerical inaccuracies and therefore configures a solution capable of detecting faults internal to the protected zone rapidly and dependably. The authors tested the proposed algorithm using data sets obtained from transmission line fault simulations performed in Alternative Transients Program (ATP), which considered noisy measurements, current transformer (CT) saturation, capacitive-coupling voltage transformer (CCVT) transients, switching onto fault, close-in faults, frequency variations, uncertainties in the line’s parameters, and power swings. Furthermore, the authors tested the presented method against measurements recorded by field protection equipment during seventy-nine actual fault events on four existing 500 [kV] lines. The results indicate that the proposed algorithm is a fast, secure, and reliable distance protection solution and that using BI to the LS-based distance protection approach increases security while maintaining fast fault detection.

25 April 2022 in IEEE Access
Verified
Journal Article
Open access
SSSilvio Di Santo
Silvio Di Santo
AAAlvaro Da Rocha Albertini
Alvaro Da Rocha Albertini
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
This paper presents an optimization-based fault location algorithm applicable to series-compensated power transmission lines. The presented method determines the fault location minimizing the errors between measured and calculated post-fault voltage and current phasors through a dynamic differential evolutionary optimization algorithm. This fault location solution may be advantageous over existing approaches found in the literature as it can locate any fault regardless of the series compensation’s design, impedance, and positioning. To validate the proposed algorithm, the authors tested it against more than a thousand and six hundred faults on a 500 [kV] series-compensated double-circuit transmission line simulated in ATP/EMTP. The results indicate that the presented method yields accurate fault location estimates, with errors within the 1% magnitude using post-fault steady-state and transient data. In addition, the proposed algorithm is robust even in situations featuring high-resistance faults, errors in the line’s parameters, in the system equivalents connected to and between the line’s terminals, and in phasor extraction, configuring it as an accurate and reliable alternative to locate faults within series-compensated lines.

25 June 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
GJGiovanni Manassero Junior
Giovanni Manassero Junior
This paper presents a time-domain differential protection method based on the Bayes’ Theorem and on the current samples to determine the fault occurrence probability as a function of time. It also describes the theory involved in developing the proposed protection method when considering the differential protection of transmission lines. The authors performed fault simulations using an existing electrical system modeled in EMTP varying the fault type, phases involved, fault resistance, inception angle, and fault location, and carried out a sensitivity analysis regarding high impedance faults, current transformer saturation, noisy data, misalignments between terminal samples and power swings. The authors also tested the proposed method against actual fault events from four existing transmission lines of the Brazilian interconnected power system. All results indicate that the proposed solution is fast, accurate, secure, and dependable.

28 November 2023 in Electrical Engineering
Verified
Journal Article
Closed access
PDF file
FBFrancisco Elânio Bezerra
Francisco Elânio Bezerra
SSSilvio Di Santo
Silvio Di Santo
GJGiovanni Manassero Junior
Giovanni Manassero Junior
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
AAAlvaro da Rocha Albertini
Alvaro da Rocha Albertini
GSGabriel Rodrigues Santos
Gabriel Rodrigues Santos

9 October 2023 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
JFJosé Renato de Arruda Bruzadin Filho
José Renato de Arruda Bruzadin Filho
Rodrigo Rozenblit TiferesRodrigo Rozenblit Tiferes
Rodrigo Rozenblit Tiferes
SSSilvio Di Santo
Silvio Di Santo
This article presents a photovoltaic module temperature estimation and sensor malfunction detection algorithm based on the Kalman filter. At a given instant, an initial estimate of the temperature is determined through a chosen thermal model, which in this research was a dynamic linear regression empirical approach, and compared with the temperature sensor's measurement using the Kalman filter. This comparison results in a gain, which is then used to determine the final and more accurate temperature estimation through a weighted average between the initial estimated value and the temperature sensor's measurement. The method detects a possible malfunction of the temperature sensor and classifies the defect as sensor off/not measuring or with noisy measurements when the differences between the values estimated by the model used and those measured by the instrumentation become sufficiently significant. The proposed methodology was tested against data recorded in a photovoltaic laboratory at the University of São Paulo, Brazil, and the results indicate that this solution can accurately assess the modules' temperature and detect temperature sensor malfunctioning, both on clear and cloudy days, on both temperature sensor shutdowns and noise-corrupted measurements situations.