Rudolf Ribeiro Riehl

Dr. Rudolf Ribeiro Riehl

UNESP - São Paulo State University
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2022 in Sensors
Verified
Journal Article
Open access
PDF file
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
VSVitor Vecina dos Santos
Vitor Vecina dos Santos
Guilherme LucasGuilherme Lucas
Guilherme Lucas
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
RRRudolf Ribeiro Riehl
Rudolf Ribeiro Riehl
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Dry-type insulated transformers stand out for their higher applicability in substations, high-voltage instrumentation systems, and electrical installations. In this machine, the insulation system is constituted of dielectric materials such as epoxy resin and Nomex paper. Some critical issues in the operation of this equipment, such as overload, moisture, or heat, can induce a slow degradation of the physical–chemical properties of the dielectric materials, which can culminate in the total failure of the transformer. However, before the transformer’s shutdown, it is common to detect discharge activity in the insulation system. Based on this issue, this work proposes an experimental and comparative analysis between acoustic emission and Hall-effect sensors, aiming at differentiating discharges in epoxy resin and Nomex paper, materials that constitute the insulation of the dry-type insulated transformers. Two signal processing techniques were studied: traditional frequency analysis and discrete wavelet transform. The objective is to develop signal processing techniques to differentiate each type of discharge since different discharges require different maintenance actions. The results obtained indicate that acoustic emission sensors and Hall sensors are promising in differentiating discharge in epoxy resin and Nomex paper. Furthermore, the pattern recognition tools presented by this work, which associated the wavelet levels energies and the energy of the full signals with the average band and the equivalent bandwidth, were effective to perform feature extraction of power transformer condition.

1 November 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
RRRudolf Ribeiro Riehl
Rudolf Ribeiro Riehl
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
JFJosé Renato Castro Pompéia Fraga
José Renato Castro Pompéia Fraga
VPVictor Puccia
Victor Puccia
Guilherme LucasGuilherme Lucas
Guilherme Lucas
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Science and industry have sought to develop systems aiming to avoid total failures in power transformers since these machines can be working under overloads, moisture, mechanical and thermal stresses, among others. These non-conformities can promote the degradation of the insulation system and lead the transformer to total failure. In the incipient stages of these faults, it is common to detect Full Discharges (FDs), which are short circuits between degraded coils. Therefore, several techniques were developed to perform FD diagnosis using UHF, acoustics, and current sensors. In this scenario, this article presents a mathematical model for Rogowski coils and compares two different types of cores: Ferrite and Teflon. For this purpose, FDs were induced in an oil-filled transformer. The sensitivity and frequency response of the Rogowski coils were compared. This analysis was achieved using the Power Spectrum Density (PSD) and the energy of the acquired signals. Additionally, the Short-Time Fourier Transform (STFT) was applied to detect repetitive discharges. The results indicated that the Ferrite core increases the sensitivity by 50 times in the frequency band between 0 and 1 MHz. However, the Teflon core showed higher sensitivity between 5 and 10 MHz.

1 November 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
Guilherme LucasGuilherme Lucas
Guilherme Lucas
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
PSPaulo José Amaral Serni
Paulo José Amaral Serni
RRRudolf Ribeiro Riehl
Rudolf Ribeiro Riehl
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Three-Phase Induction Motors (TIMs) are widely applied in industries. Therefore, there is a need to reduce operational and maintenance costs since their stoppages can impair production lines and lead to financial losses. Among all the TIM components, bearings are crucial in the machine operation once they couple rotor to the motor frame. Furthermore, they are constantly subjected to friction and mechanical wearing. Consequently, they represent around 41% of the motor fault, according to IEEE. In this context, several studies have sought to develop monitoring systems based on different types of sensors. Therefore, considering the high demand, this article aims to present the state of the art of the past five years concerning the sensing techniques based on current, vibration, and infra-red analysis, which are characterized as promising tools to perform bearing fault detection. The current and vibration analysis are powerful tools to assess damages in the inner race, outer race, cages, and rolling elements of the bearings. These sensing techniques use current sensors like hall effect-based, Rogowski coils, and current transformers, or vibration sensors such as accelerometers. The effectiveness of these techniques is due to the previously developed models, which relate the current and vibration frequencies to the origin of the fault. Therefore, this article also presents the bearing fault mathematical modeling for these techniques. The infra-red technique is based on heat emission, and several image processing techniques were developed to optimize bearing fault detection, which is presented in this review. Finally, this work is a contribution to pushing the frontiers of the bearing fault diagnosis area.

14 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
DADaniele F. Akiyoshi
Daniele F. Akiyoshi
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
JLJosé V. F. Leão
José V. F. Leão
Marco Aurélio RochaMarco Aurélio Rocha
Marco Aurélio Rocha
JRJorge Alfredo Ardila Rey
Jorge Alfredo Ardila Rey
AAAndre Luiz Andreoli
Andre Luiz Andreoli
Transformers are essential equipment in electrical energy systems and their failure may lead to the loss of a power supply. Both industry and science have sought to develop sensors and low-cost solutions for the correct diagnosis of their failures. Thus, the use of piezoelectric sensors in the diagnosis of partial discharge in power transformers has been growing significantly, in order to ensure the reduction of maintenance costs, as well as the quality of electric power supply, since this type of failure can lead to a significant cost of repair. In many cases, when partial discharge is detected, there is no immediate need to promote transformer maintenance. In this way, it becomes reasonable to study the evolution of this phenomenon, so that the maintenance of the device can be scheduled and performed correctly. In this regard, this article presents a feasibility study of a low-cost piezoelectric transducer for the identification of the evolution level of partial discharges. For this purpose, in a 30 kVA distribution transformer, three corona partial discharges were produced under three different voltage levels, using a copper electrode. The low cost piezoelectric sensor was coupled to the transformer housing. The acoustic emission signals of the three partial discharge levels were captured and analyzed by the use of acoustic signal metrics, such as energy, peak value, and power spectral density. The experimental results indicated that the low cost sensor is able to identify the evolution of the partial discharge intensity, since the values obtained by the metrics are directly related to the partial discharge levels. Therefore, the results reported in this study indicate that the piezoelectric transducer has a great applicability in diagnosing the partial discharges evolution, and, thus, can assist in the planning of electrical maintenance.

1 November 2021 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
Guilherme LucasGuilherme Lucas
Guilherme Lucas
GFGabriel Scota Fernandes
Gabriel Scota Fernandes
JFJosé Renato Castro Pompéia Fraga
José Renato Castro Pompéia Fraga
RRRudolf Ribeiro Riehl
Rudolf Ribeiro Riehl
AAAndre Luiz Andreoli
Andre Luiz Andreoli
The quality of power systems is related to their capability to predict failures, avoid stoppages, and increase the lifetime of their components. Therefore, science has been developing monitoring systems to identify failures in induction motors, transformers, and transmission lines. In this context, one of the most crucial components of the electrical systems is the insulation devices such as bushings, which are constantly subjected to dust, thermal stresses, moisture, etc. These conditions promote insulation deterioration, leading to the occurrence of partial discharges. Partial discharges are localized dielectric breakdown that emits ultra-violet radiation, heat, electromagnet, and acoustics waves. The most traditional techniques to identify these flaws on bushings are based on the current, ultra high frequency, and acoustic emission analysis. However, thermal analysis stands out as a noise-resistant technique to monitor several components in the power systems. Although the thermal method is applied to detect different types of faults, such as bad contacts, overloads, etc, this technique has not been previously applied to perform partial discharge detection and evaluate its evolution on bushings. Based on this issue, this article proposes two new indexes to characterize the discharge evolution based on the infrared thermal analysis: the area ratio coefficient and the Red, Green, and Blue (RGB) ratio coefficient. Seven discharge levels were induced in a contaminated bushing, and an infrared thermal camera captured 20 images per condition, totalizing 140 images. New coefficients were used to perform the identification of discharge evolution. Results indicated that values of the new indexes increase with the partial discharge activity. Thus, the new imaging processing approach can be a promising contribution to literature, improving the reliability and maintenance planning for power transmission systems.