Rui Varandas

Mr. Rui Varandas

LIBPhys (Laboratory for Instrumentation, Biomedical Engineering and Radiation Physics), Faculdade de Ciências e Tecnologia, Universidade Nova de Lisboa, Caparica, Portugal
+1
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 May 2022 in Sensors
Verified
Journal Article
Open access
PDF file
RVRui Varandas
Rui Varandas
RLRodrigo Olival Lima
Rodrigo Olival Lima
Sergi Bermúdez i BadiaSergi Bermúdez i Badia
Sergi Bermúdez i Badia
Hugo Plácido da SilvaHugo Plácido da Silva
Hugo Plácido da Silva
Hugo GamboaHugo Gamboa
Hugo Gamboa
Wearable sensors have increasingly been applied in healthcare to generate data and monitor patients unobtrusively. Their application for Brain–Computer Interfaces (BCI) allows for unobtrusively monitoring one’s cognitive state over time. A particular state relevant in multiple domains is cognitive fatigue, which may impact performance and attention, among other capabilities. The monitoring of this state will be applied in real learning settings to detect and advise on effective break periods. In this study, two functional near-infrared spectroscopy (fNIRS) wearable devices were employed to build a BCI to automatically detect the state of cognitive fatigue using machine learning algorithms. An experimental procedure was developed to effectively induce cognitive fatigue that included a close-to-real digital lesson and two standard cognitive tasks: Corsi-Block task and a concentration task. Machine learning models were user-tuned to account for the individual dynamics of each participant, reaching classification accuracy scores of around 70.91 ± 13.67 %. We concluded that, although effective for some subjects, the methodology needs to be individually validated before being applied. Moreover, time on task was not a particularly determining factor for classification, i.e., to induce cognitive fatigue. Further research will include other physiological signals and human–computer interaction variables.

6 May 2024 in Virtual Reality
Verified
Journal Article
Open access
PDF file
RLRodrigo Olival Lima
Rodrigo Olival Lima
ACAlice Chirico
Alice Chirico
RVRui Varandas
Rui Varandas
Hugo GamboaHugo Gamboa
Hugo Gamboa
AGAndrea Gaggioli
Andrea Gaggioli
Sergi Bermúdez i BadiaSergi Bermúdez i Badia
Sergi Bermúdez i Badia
Affective computing has been widely used to detect and recognize emotional states. The main goal of this study was to detect emotional states using machine learning algorithms automatically. The experimental procedure involved eliciting emotional states using film clips in an immersive and non-immersive virtual reality setup. The participants’ physiological signals were recorded and analyzed to train machine learning models to recognize users’ emotional states. Furthermore, two subjective ratings emotional scales were provided to rate each emotional film clip. Results showed no significant differences between presenting the stimuli in the two degrees of immersion. Regarding emotion classification, it emerged that for both physiological signals and subjective ratings, user-dependent models have a better performance when compared to user-independent models. We obtained an average accuracy of 69.29 ± 11.41% and 71.00 ± 7.95% for the subjective ratings and physiological signals, respectively. On the other hand, using user-independent models, the accuracy we obtained was 54.0 ± 17.2% and 24.9 ± 4.0%, respectively. We interpreted these data as the result of high inter-subject variability among participants, suggesting the need for user-dependent classification models. In future works, we intend to develop new classification algorithms and transfer them to real-time implementation. This will make it possible to adapt to a virtual reality environment in real-time, according to the user’s emotional state.

24 March 2022 in Computers
Verified
Journal Article
Open access
PDF file
Patricia GamboaPatricia Gamboa
Patricia Gamboa
RVRui Varandas
Rui Varandas
JRJoão Rodrigues
João Rodrigues
Catia Cepeda de Vela BastosCatia Cepeda de Vela Bastos
Catia Cepeda de Vela Bastos
Claudia QuaresmaClaudia Quaresma
Claudia Quaresma
Hugo GamboaHugo Gamboa
Hugo Gamboa
Occupational disorders considerably impact workers’ quality of life and organizational productivity, and even affect mortality worldwide. Such health issues are related to mental health and ergonomics risk factors. In particular, mental health may be affected by cognitive strain caused by unexpected interruptions and other attention compromising factors. Risk factors assessment associated with cognitive strain in office environments, namely related to attention states, still suffers from the lack of scientifically validated tools. In this work, we aim to develop a series of classification models that can classify attention during pre-defined cognitive tasks based on the acquisition of biosignals to create a ground truth of attention. Biosignals, such as electrocardiography, electroencephalography, and functional near-infrared spectroscopy, were acquired from eight subjects during standard cognitive tasks inducing attention. Individually tuned machine learning models trained with those biosignals allowed us to successfully detect attention on the individual level, with results in the range of 70–80%. The electroencephalogram and electrocardiogram were revealed to be the most appropriate sensors in this context, and the combination of multiple sensors demonstrated the importance of using multiple sources. These models prove to be relevant for the development of attention identification tools by providing ground truth to determine which human–computer interaction variables have strong associations with attention.

12 March 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Patricia GamboaPatricia Gamboa
Patricia Gamboa
RVRui Varandas
Rui Varandas
KMKatrin Mrotzeck
Katrin Mrotzeck
Hugo Plácido da SilvaHugo Plácido da Silva
Hugo Plácido da Silva
Claudia QuaresmaClaudia Quaresma
Claudia Quaresma
Electrodermal activity (EDA) reflects the variation in the electrical conductance of the skin in response to sweat secretion, constituting a non-invasive measure of the sympathetic nervous system. This system intervenes in reactions to stress and is strongly activated in emotional states. In most cases, EDA signals are collected from the hand (fingers or palms), which is not an ideal location for a sensor when the participant has to use their hands during tasks or activities. This study aims to explore alternative locations for retrieving EDA signals (e.g., the chest, back, and forehead). EDA signals from 25 healthy participants were collected using a protocol involving different physical stimuli that have been reported to induce an electrodermal response. The features extracted included the Skin Conductance Response (SCR) height, SCR amplitude, and peak prominence. An analysis of these features and the analysis of the correlation between the standard position with the different locations suggested that the chest, while a possible alternative for EDA signal collection, presents some weak results, and further evaluation of this site is needed. Additionally, the forehead should be excluded as an alternative site, at least in short-term measurements.

17 January 2022 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
RVRui Varandas
Rui Varandas
BGBernardo Brás Gonçalves
Bernardo Brás Gonçalves
Hugo GamboaHugo Gamboa
Hugo Gamboa
PVPedro M. Vieira
Pedro M. Vieira
In clinical practice, every decision should be reliable and explained to the stakeholders. The high accuracy of deep learning (DL) models pose a great advantage, but the fact that they function as black-boxes hinders their clinical applications. Hence, explainability methods became important as they provide explanation to DL models. In this study, two datasets with electrocardiogram (ECG) image representations of six heartbeats were built, one given the label of the last heartbeat and the other given the label of the first heartbeat. Each dataset was used to train one neural network. Finally, we applied well-known explainability methods to the resulting networks to explain their classifications. Explainability methods produced attribution maps where pixels intensities are proportional to their importance to the classification task. Then, we developed a metric to quantify the focus of the models in the heartbeat of interest. The classification models achieved testing accuracy scores of around 93.66% and 91.72%. The models focused around the heartbeat of interest, with values of the focus metric ranging between 8.8% and 32.4%. Future work will investigate the importance of regions outside the region of interest, besides the contribution of specific ECG waves to the classification.

30 December 2019
Verified
Conference Paper
Open access
Miquel AlfarasMiquel Alfaras
Miquel Alfaras
RVRui Varandas
Rui Varandas
Hugo GamboaHugo Gamboa
Hugo Gamboa