Rui Zhang

Prof. Rui Zhang

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in IEEE Access
Verified
Journal Article
Open access
XZXincan Zhao
Xincan Zhao
CLChenyang Liu
Chenyang Liu
ZXZongxin Xu
Zongxin Xu
LZLipeng Zhang
Lipeng Zhang
RZRui Zhang
Rui Zhang
Steady-state visual evoked potentials-based brain-computer interfaces (SSVEP-BCI) has the advantage of high information transfer rate (ITR) and little user training, and it has a high application value in the field of disability assistance and human-computer interaction. Generally SSVEP-BCI requires a personal computer screen (PC) to display several repetitive visual stimuli for inducing the SSVEP response, which reduces its portability and flexibility. Using augmented reality (AR) glasses worn on the head to display the repetitive visual stimuli could solve the above drawbacks, but whether it could achieve the same accuracy as PC screen in the case of reduced brightness and increased interference is unknown. In current study, we firstly designed 4 stimulus layouts and displayed them with Microsoft HoloLens (AR-SSVEP) glasses, comparison analysis showed that the classification accuracies are influenced by the stimulus layout when the stimulus duration is less than 3s. When the stimulus duration exceeds 3s, there is no significant accuracy difference between the 4 layouts. Then we designed a similar experimental paradigm on PC screen (PC-SSVEP) based on the best layout of AR. Classification results showed that AR-SSVEP achieved similar accuracy with PC-SSVEP when the stimulus duration is more than 3s, but when the stimulus duration is less than 2s, the accuracy of AR-SSVEP is lower than PC-SSVEP. Brain topological analysis indicated that the spatial distribution of SSVEP responses is similar, both of which are strongest in the occipital region. Current study indicated that stimulus layout is a key factor when building SSVEP-BCI with AR glasses, especially when the stimulation time is short.

17 May 2019 in IEEE Access
Verified
Journal Article
Open access
RZRui Zhang
Rui Zhang
XLXianpeng Li
Xianpeng Li
YWYinwang Wang
Yinwang Wang
BLBo Liu
Bo Liu
LSLi Shi
Li Shi
YHYuxia Hu
Yuxia Hu
Motor imagery-based brain-computer interface (MI-BCI) inefficiency phenomenon is one of the biggest challenges in MI-BCI research. BCI inefficiency subject is defined as the subject who cannot achieve classification accuracy higher than 70%, since 70% is considered to be the minimum accuracy for communication by BCI. About 15-30% of the people are MI-BCI inefficiency according to investigation. Most of the existing studies used common spatial patterns (CSP) to extract motor imagery feature and identify MI-BCI inefficiency subject based on the obtained classification accuracy. We think the MI-BCI performance maybe suppressed because CSP mainly extract event-related desynchronization (ERD) feature, while the features generated by motor imagery are more than that. In current work, we screened 12 MI-BCI inefficiency subjects by CSP feature firstly, and recorded the motor imagery EEG data of them. Then we constructed task-related brain network by calculating the coherence between EEG channels, graph-based analysis showed that the node degree and clustering coefficient have intensity differences between left and right hand motor imagery. Finally, the two kind of features were used to discriminate the two tasks, results showed that both node degree and clustering coefficient features perform better than CSP, and the feature combination of brain network and CSP achieved higher accuracy than single feature. In particular, 4 subjects achieved accuracy higher than 70% by node degree and CSP features fusion. This work demonstrates that the accuracy of MI-BCI inefficiency subject can be increased by using brain network feature, but the accuracy gains are not high enough, it is worth to try other types of feature extraction algorithms for MI-BCI inefficiency subject.

13 May 2022 in Journal of Neural Engineering
Verified
Journal Article
Closed access
RZRui Zhang
Rui Zhang
ZXZongxin Xu
Zongxin Xu
LZLipeng Zhang
Lipeng Zhang
LCLijun Cao
Lijun Cao
YHYuxia Hu
Yuxia Hu
XZXincan Zhao
Xincan Zhao
Objective . The biggest advantage of steady-state visual evoked potential (SSVEP)-based brain–computer interface (BCI) lies in its large command set and high information transfer rate (ITR). Almost all current SSVEP–BCIs use a computer screen (CS) to present flickering visual stimuli, which limits its flexible use in actual scenes. Augmented reality (AR) technology provides the ability to superimpose visual stimuli on the real world, and it considerably expands the application scenarios of SSVEP–BCI. However, whether the advantages of SSVEP–BCI can be maintained when moving the visual stimuli to AR glasses is not known. This study investigated the effects of the stimulus number for SSVEP–BCI in an AR context. Approach. We designed SSVEP flickering stimulation interfaces with four different numbers of stimulus targets and put them in AR glasses and a CS to display. Three common recognition algorithms were used to analyze the influence of the stimulus number and stimulation time on the recognition accuracy and ITR of AR–SSVEP and CS–SSVEP. Main results. The amplitude spectrum and signal-to-noise ratio of AR–SSVEP were not significantly different from CS–SSVEP at the fundamental frequency but were significantly lower than CS–SSVEP at the second harmonic. SSVEP recognition accuracy decreased as the stimulus number increased in AR–SSVEP but not in CS–SSVEP. When the stimulus number increased, the maximum ITR of CS–SSVEP also increased, but not for AR–SSVEP. When the stimulus number was 25, the maximum ITR (142.05 bits min −1 ) was reached at 400 ms. The importance of stimulation time in SSVEP was confirmed. When the stimulation time became longer, the recognition accuracy of both AR–SSVEP and CS–SSVEP increased. The peak value was reached at 3 s. The ITR increased first and then slowly decreased after reaching the peak value. Significance . Our study indicates that the conclusions based on CS–SSVEP cannot be simply applied to AR–SSVEP, and it is not advisable to set too many stimulus targets in the AR display device.

20 November 2013 in Computational and Mathematical Methods in Medicine
Verified
Journal Article
Open access
PDF file
RZRui Zhang
Rui Zhang
PXPeng Xu
Peng Xu
TLTiejun Liu
Tiejun Liu
Yangsong ZhangYangsong Zhang
Yangsong Zhang
LGLanjin Guo
Lanjin Guo
DYDezhong Yao
Dezhong Yao
Common spatial pattern (CSP) is one of the most popular and effective feature extraction methods for motor imagery-based brain-computer interface (BCI), but the inherent drawback of CSP is that the estimation of the covariance matrices is sensitive to noise. In this work, local temporal correlation (LTC) information was introduced to further improve the covariance matrices estimation (LTCCSP). Compared to the Euclidean distance used in a previous CSP variant named local temporal CSP (LTCSP), the correlation may be a more reasonable metric to measure the similarity of activated spatial patterns existing in motor imagery period. Numerical comparisons among CSP, LTCSP, and LTCCSP were quantitatively conducted on the simulated datasets by adding outliers to Dataset IVa of BCI Competition III and Dataset IIa of BCI Competition IV, respectively. Results showed that LTCCSP achieves the highest average classification accuracies in all the outliers occurrence frequencies. The application of the three methods to the EEG dataset recorded in our laboratory also demonstrated that LTCCSP achieves the highest average accuracy. The above results consistently indicate that LTCCSP would be a promising method for practical motor imagery BCI application.

1 February 2022 in Computers in Biology and Medicine
Verified
Journal Article
Open access
XZXincan Zhao
Xincan Zhao
YDYulin Du
Yulin Du
RZRui Zhang
Rui Zhang
Because an augmented-reality-based brain-computer interface (AR-BCI) is easily disturbed by external factors, the traditional electroencephalograph (EEG) classification algorithms fail to meet the real-time processing requirements with a large number of stimulus targets or in a real environment. We propose a multi-target fast classification method for augmented-reality-based steady-state visual evoked potential (AR-SSVEP), using a convolutional neural network (CNN). To explore the availability and accuracy of high-efficiency multi-target classification methods in AR-SSVEP with a short stimulation duration, a similar stimulus layout was used for a computer screen (PC) and an optical see-through head-mounted display (OST-HMD) device (HoloLens). The experiment included nine flicker stimuli of different frequencies, and a multi-target fast classification method based on a CNN was constructed to complete nine classification tasks, for which the average accuracy of AR-BCI in our CNN model at 0.5- and 1-s stimulus duration was 67.93% and 80.83%, respectively. These results verified the efficacy of the proposed model for processing multi-target classification in AR-BCI.

23 March 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
RZRui Zhang
Rui Zhang
LCLijun Cao
Lijun Cao
ZXZongxin Xu
Zongxin Xu
YZYangsong Zhang
Yangsong Zhang
LZLipeng Zhang
Lipeng Zhang
DYDezhong Yao
Dezhong Yao
Augmented reality-based brain-computer interface (AR-BCI) system is one of the important ways to promote BCI technology outside of the laboratory due to its portability and mobility, but its performance in real-world scenarios has not been fully studied. In the current study, we first investigated the effect of ambient brightness on AR-BCI performance. 5 different light intensities were set as experimental conditions to simulate typical brightness in real scenes, while the same steady-state visual evoked potentials (SSVEP) stimulus was displayed in the AR glass. The data analysis results showed that SSVEP can be evoked under all 5 light intensities, but the response intensity became weaker when the brightness increased. The recognition accuracies of AR-SSVEP were negatively correlated to light intensity, the highest accuracies were 89.35% with FBCCA and 83.33% with CCA under 0 lux light intensity, while they decreased to 62.53% and 49.24% under 1200 lux. To solve the accuracy loss problem in high ambient brightness, we further designed a SSVEP recognition algorithm with iterative learning capability, named ensemble online adaptive CCA (eOACCA). The main strategy is to provide initial filters for high-intensity data by iteratively learning low-light-intensity AR-SSVEP data. The experimental results showed that the eOACCA algorithm had significant advantages under higher light intensities (>600 lux). Compared with FBCCA, the accuracy of eOACCA under 1200 lux was increased by 13.91%. In conclusion, the current study contributed to the in-depth understanding of the performance variations of AR-BCI under different lighting conditions, and was helpful in promoting the AR-BCI application in complex lighting environments.