Runqing Li

Prof. Runqing Li

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Cancer Investigation
Verified
Journal Article
Closed access
BSBao-En Shan
Bao-En Shan
MWMing-Xia Wang
Ming-Xia Wang
RLRunqing Li
Runqing Li
The Wnt signaling pathway plays a pivotal role in cellular developmental processes and human carcinogenesis. The aim of this study was to investigate the effects of quercetin on the growth of the colon carcinoma cell line and the regulation effect of quercetin on the Wnt/beta-catenin signaling pathway. MTT assay was used to determine the reduction of cell viability of quercetin on SW480 cells and clone 26 cells. The apoptotic rate and cell-cycle analysis after treatment with quercetin was determined by flow cytometry. Effects of quercetin on mRNA expression of cyclin D(1) and survivin were detected by semiquantitative RT-PCR. After treatment with quercetin, the protein expression of cyclin D(1) and survivin in SW480 cells was analyzed by Western blot analysis. We built a Wnt/beta-catenin signaling pathway reporter gene model. The regulation effect of quercetin on the Wnt/beta-catenin signaling transcription was investigated by using this reporter gene model. Quercetin reduced cell viability in a dose- and time-dependent manner in SW480 and clone 26 cells. The percentages of SW480 cells and clone 26 cells at G(2)/M phase were increased significantly after treatment with 40 approximately 80 micromol/L quercetin for 48 hours. Quercetin induced the apoptosis of SW480 cells in a dose-dependent manner at the concentration of 20, 40, 60, anf 80 micromol/L. However, quercetin only induced the apoptosis of clone 26 cells at the concentration of 80 micromol/L. Quercetin downregulated transcriptional activity of beta-catenin/Tcf in SW480 cells transiently transfected with the TCF-4 reporter gene. Within 24 hours of treatment, a 160-mumol/L concentration of quercetin reduced beta-catenin/Tcf transcriptional activity by about 18-fold. Cyclin D(1) and the survivin gene were downregulated markedly by quercetin in a dose-dependent manner at both the transcription and protein expression levels. The results indicate that the molecular mechanism underlying the antitumor effect of quercetin in SW480 colon cancer cells is related to the inhibition of expression of cyclin D(1) and survivin as well as the Wnt/beta-catenin signaling pathway. Therefore, the Wnt/beta-catenin signaling pathway could be qualified as one of the promising targets for innovative treatment strategies of colorectal cancer.

1 June 2013 in Diagnostic Microbiology and Infectious Disease
Verified
Journal Article
Closed access
DZDong Zhu
Dong Zhu
XZXiu-Ying Zhao
Xiu-Ying Zhao
YYYao Yao
Yao Yao
FDFang-Fang Dai
Fang-Fang Dai
HHHan He
Han He
NLNing Li
Ning Li

18 September 2019 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Open access
PDF file
RLRunqing Li
Runqing Li
TWTengjiao Wang
Tengjiao Wang
LGLijun Gong
Lijun Gong
JDJingxiao Dong
Jingxiao Dong
NXNan Xiao
Nan Xiao
ZZZhipeng Zhao
Zhipeng Zhao
Background: Accurate and timely clinical laboratory critical values notification are crucial steps in supporting effective clinical decision making, thereby improving patient safety. Methods: A closed‐loop laboratory critical value notification system was developed by a multidisciplinary team of clinicians, laboratorians, administrators, and information technology experts. All the laboratory critical values that occurred at Beijing Tsinghua Changgung Hospital (BTCH, Beijing, China) from 2015 to 2019 were analyzed and studied retrospectively. Results: The total number (ratio) of institutional laboratory critical values to all reported items at BTCH from 2015 to 2019 was 38 020/7 706 962 (0.49%). Percentage distribution points of critical value boundaries based on patients’ test reports are 0.007% ~ 6.04% for low boundaries and 71.70% ~ 99.99% for high boundaries. After the intervention, the timely notification ratio, notification receipt ratio, and timely notification receipt ratio of critical values of ED, IPD, and total patients had increased, with a significant difference ( P < .001). Five quality indicators, such as notification ratio, timely notification ratio, notification receipt ratio, timely notification receipt ratio, and clinician response ratio over a 5‐year period, were 100%, 94%, 97%, 92%, and 99%, respectively. Conclusions: We enhanced the effectiveness of clinical laboratory critical values initiative notification by implementing a closed‐loop system and intervening. Clinical critical values and quality indicators should be analyzed and monitored to avoid adversely affecting patient care.

7 February 2019 in Archives of Virology
Verified
Journal Article
Closed access
PDF file
DZDong Zhu
Dong Zhu
CLChonghou Lok
Chonghou Lok
SCShuang Chao
Shuang Chao
LCLingling Chen
Lingling Chen
RLRunqing Li
Runqing Li
XZXiu-ying Zhao
Xiu-ying Zhao

6 August 2019 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Open access
RLRunqing Li
Runqing Li
TWTengjiao Wang
Tengjiao Wang
LGLijun Gong
Lijun Gong
PPPeng Peng
Peng Peng
SYSong Yang
Song Yang
PXPan Xiong
Pan Xiong
Introduction: Two methods were compared for evaluating the sigma metrics of clinical biochemistry tests using two different allowable total error (TEa) specifications.Materials and methods: The imprecision (CV%) and bias (bias%) of 19 clinical biochemistry analytes were calculated using a trueness verification proficiency testing (TPT)‐based approach and an internal quality control data inter‐laboratory comparison (IQC)‐based approach, respectively. Two sources of total allowable error (TEa), the Clinical Laboratory Improvement Amendments of 1988 (CLIA '88) and the People's Republic of China Health Industry Standard (WS/T 403‐2012), were used to calculate the sigma metrics (σCLIA, σWS/T). Sigma metrics were calculated to provide a single value for assessing the quality of each test based on a single concentration level.Results: For both approaches, σCLIA > σWS/T in 18 out of 19 assays. For the TPT‐based approach, 16 assays showed σCLIA > 3, and 12 assays showed σWS/T > 3. For the IQC‐based approach, 19 and 16 assays showed σCLIA > 3 and σWS/T > 3, respectively.Conclusions: Both methods can be used as references for calculating sigma metrics and designing QC schedules in clinical laboratories. Sigma metrics should be evaluated comprehensively by different approaches.

20 June 2019 in Journal of Clinical Laboratory Analysis
Verified
Journal Article
Open access
PDF file
RLRunqing Li
Runqing Li
YXYajun Xue
Yajun Xue
TWTengjiao Wang
Tengjiao Wang
LGLijun Gong
Lijun Gong
PPPeng Peng
Peng Peng
XYXinchen Ye
Xinchen Ye
Background: Low concentration C‐reactive protein (CRP) has favorable prognostic significance in patients with cardiovascular risks.Methods: We compared the wr‐CRP method with the hs‐CRP method both on Roche Cobas c702 analyzer for the determination of low CRP concentration (<20 mg/L) including 200 patients treated in Cardiology Department in Beijing Tsinghua Changgung Hospital (Beijing, China) from December 2018 to March 2019.Results: The two methods were highly correlated (Spearman's rho = 0.995). Deming regression was used to fit the regression analysis model, giving a slope of 1.058 with an intercept of 0.008. The median method difference (wr‐CRP − hr‐CRP) was 0.120 mg/L (95% CI, 0.086‐0.200 mg/L), and the median percent differences were 7.34% (95% CI, 4.27%‐8.47%). The percent bias between both methods at the given cutoff CRP values of 1, 3, and 10 mg/L evaluated by Deming regression was 6.60%, 6.07%, and 5.88%, respectively, all of which were less than the acceptable standard (12.50%). The percentage of sample results concordant by both methods for the risk stratification was 96.0% (kappa = 0.937, P < 0.001).Conclusions: Roche wr‐CRP and hs‐CRP assays are highly concordant in determining low concentration CRP. Wr‐CRP may be used as an alternative to hs‐CRP assay on Roche Cobas c702 analyzer to assess the cardiovascular risk, considering its convenience and lower costs.