Parametric mapping techniques provide a non-invasive tool for quantifying tissue alterations in myocardial disease in those eligible for cardiovascular magnetic resonance (CMR). Parametric mapping with CMR now permits the routine spatial visualization and quantification of changes in myocardial composition based on changes in T1, T2, and T2*(star) relaxation times and extracellular volume (ECV). These changes include specific disease pathways related to mainly intracellular disturbances of the cardiomyocyte (e.g., iron overload, or glycosphingolipid accumulation in Anderson-Fabry disease); extracellular disturbances in the myocardial interstitium (e.g., myocardial fibrosis or cardiac amyloidosis from accumulation of collagen or amyloid proteins, respectively); or both (myocardial edema with increased intracellular and/or extracellular water). Parametric mapping promises improvements in patient care through advances in quantitative diagnostics, inter- and intra-patient comparability, and relatedly improvements in treatment. There is a multitude of technical approaches and potential applications. This document provides a summary of the existing evidence for the clinical value of parametric mapping in the heart as of mid 2017, and gives recommendations for practical use in different clinical scenarios for scientists, clinicians, and CMR manufacturers.
9 September 2005 in Magnetic Resonance Materials in Physics, Biology and Medicine
Purpose: To test the hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously using a single four‐dimensional (4D) acquisition.Methods: A free‐running 4D whole‐heart self‐navigated acquisition incorporating a golden angle radial trajectory was implemented and tested in vivo in nine healthy adult human subjects. Coronary magnetic resonance angiography (MRA) datasets with retrospective selection of acquisition window width and position were extracted and quantitatively compared with baseline self‐navigated electrocardiography (ECG) ‐triggered coronary MRA. From the 4D datasets, the left‐ventricular end‐systolic, end‐diastolic volumes (ESV & EDV) and ejection fraction (EF) were computed and compared with values obtained from conventional 2D cine images.Results: The 4D datasets enabled dynamic assessment of the whole heart with isotropic spatial resolution of 1.15 mm3. Coronary artery image quality was very similar to that of the ECG‐triggered baseline scan despite some SNR penalty. A good agreement between 4D and 2D cine imaging was found for EDV, ESV, and EF.Conclusion: The hypothesis that both coronary anatomy and ventricular function can be assessed simultaneously in vivo has been tested positive. Retrospective and flexible acquisition window selection allows to best visualize each coronary segment at its individual time point of quiescence. Magn Reson Med 74:1306–1316, 2015.
Purpose: To assess renal glomerular homing of intravenously injected superparamagnetic iron oxide (SPIO)-labeled mesenchymal stem cells (MSCs) at in vivo and ex vivo magnetic resonance (MR) imaging in an experimental rat model of mesangiolysis. Materials and Methods: Animal procedures were performed in accordance with protocols approved by Institutional Animal Care and Use Committee. Fourteen rats were divided into two groups: one pathologic (n = 10), with persistent mesangiolysis following simultaneous injection of OX-7 monoclonal antibody and puromycin aminonucleoside in which 107 SPIO- and DiI-labeled MSCs were injected, and one control (n = 4). In vivo and ex vivo MR imaging examinations were performed with 4.7- and 9.4-T spectrometers, respectively, and T2*-weighted sequences. In vivo signal intensity variations were measured in the liver and kidney before and 6 days after MSC injection. Intrarenal signal intensity variations were correlated with histopathologic data by means of colocalization of DiI...
To assess the diagnostic performance of respiratory self-navigation for whole-heart coronary magnetic resonance (MR) angiography in a patient cohort referred for diagnostic cardiac MR imaging. Written informed consent was obtained from all participants for this institutional review board-approved study. Self-navigated coronary MR angiography was performed after administration of a contrast agent in 78 patients (mean age, 48.5 years ± 20.7 [standard deviation]; 53 male patients) referred for cardiac MR imaging because of coronary artery disease (n = 40), cardiomyopathy (n = 14), congenital anomaly (n = 17), or "other" (n = 7). Examination duration was recorded, and the image quality for each coronary segment was assessed with consensus reading. Vessel sharpness, length, and diameter were measured. Quantitative values in proximal, middle, and distal segments were compared by using analysis of variance and t tests. A double-blinded comparison with the results of x-ray angiography was performed when such results were available. When patients with different indications for cardiac MR imaging were examined with self-navigated postcontrast coronary MR angiography, whole-heart data sets with 1.15-mm isotropic spatial resolution were acquired in an average of 7.38 minutes ± 1.85. The main and proximal coronary segments could be visualized in 92.3% of cases, while the middle and distal segments could be visualized in 84.0% and 55.8% of cases, respectively. Subjective scores and vessel sharpness were significantly higher in the proximal segments than in the middle and distal segments (P < .05). Anomalies of the coronary arteries could be confirmed or excluded in all cases. Per-vessel sensitivity and specificity for stenosis detection were 64.7% and 85.0%, respectively, in the 31 patients for whom reference standard x-ray coronary angiography results were available. The self-navigated coronary MR angiography sequence shows promise for coronary imaging. However, technical improvements are needed to improve image quality, especially in the more distal coronary segments.
12 May 2010 in Physical Chemistry Chemical Physics
The increase of total choline in tumors has become an important biomarker in cancer diagnosis. Choline and choline metabolites can be measured in vivo and in vitro using multinuclear MRS. Recent in vivo13C MRS studies using labeled substrates enhanced via dynamic nuclear polarization demonstrated the tremendous potential of hyperpolarization for real-time metabolic studies. The present study demonstrates the feasibility of detecting hyperpolarized 15N labeled choline in vivo in a rat head at 9.4 T. We furthermore report the in vitro (172 ± 16 s) and in vivo (126 ± 15 s) longitudinal relaxation times. We conclude that with appropriate infusion protocols it is feasible to detect hyperpolarized 15N labeled choline in live animals.