Sabrina Di Masi

Dr. Sabrina Di Masi

Department of Biological and Environmental Sciences and Technologies, University of Salento, Via per Monteroni, 73100 Lecce (Italy)
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2021 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KAKaseb Alanazi
Kaseb Alanazi
ACALVARO GARCIA CRUZ
ALVARO GARCIA CRUZ
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
AVAnnelies Voorhaar
Annelies Voorhaar
OAOmar Sheej Ahmad
Omar Sheej Ahmad
SPSergey A. Piletsky
Sergey A. Piletsky

1 March 2020 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
Antonio PennettaAntonio Pennetta
Antonio Pennetta
AGAntonio Guerreiro
Antonio Guerreiro
FCFrancesco Canfarotta
Francesco Canfarotta
GBGiuseppe Egidio De Benedetto
Giuseppe Egidio De Benedetto
CMCosimino Malitesta
Cosimino Malitesta

13 February 2019 in Biosensors
Verified
Journal Article
Open access
PDF file
GBGiuseppe De Benedetto
Giuseppe De Benedetto
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
Antonio PennettaAntonio Pennetta
Antonio Pennetta
CMCosimino Malitesta
Cosimino Malitesta
Herein, we report the application of a chemometric tool for the optimisation of electrochemical biosensor performances. The experimental design was performed based on the responses of an amperometric biosensor developed for metal ions detection using the flow injection analysis. The electrode preparation and the working conditions were selected as experimental parameters, and thus, were modelled by a response surface methodology (RSM). In particular, enzyme concentration, flow rates, and number of cycles were reported as continuous factors, while the sensitivities of the biosensor (S, µA·mM−1) towards metals, such as Bi3+ and Al3+ were collected as responses and optimised by a central composite design (CCD). Bi3+ and Al3+ inhibition on the Pt/PPD/GOx biosensor response is for the first time reported. The optimal enzyme concentration, scan cycles and flow rate were found to be 50 U·mL−1, 30 and, 0.3 mL·min−1, respectively. Descriptive/predictive performances are discussed: the sensitivities of the optimised biosensor agreed with the experimental design prediction. The responses under the optimised conditions were also tested towards Ni2+ and Ag+ ions. The multivariate approach used in this work allowed us to obtain a wide working range for the biosensor, coupled with a high reproducibility of the response (RSD = 0.72%).

1 March 2019 in Chemnanomat
Verified
Journal Article
Closed access
PDF file
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
ACALVARO GARCIA CRUZ
ALVARO GARCIA CRUZ
FCFrancesco Canfarotta
Francesco Canfarotta
TCTodd Cowen
Todd Cowen
PMPedro Marote
Pedro Marote
SPSergey A. Piletsky
Sergey A. Piletsky

6 July 2017 in Frontiers in Chemistry
Verified
Journal Article
Open access
CMCosimino Malitesta
Cosimino Malitesta
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
EMElisabetta Mazzotta
Elisabetta Mazzotta
Recent work relevant to heavy metal determination by inhibition-enzyme electrochemical biosensors and by selected biomimetic sensors based on molecularly imprinted polymers has been reviewed. General features and peculiar aspects have been evidenced. The replace of biological component by artificial receptors promises higher selectivity and stability, while biosensors keep their capability of producing an integrated response directly related to toxicity of the samples.

28 May 2021 in Nanoscale Advances
Verified
Journal Article
Open access
PDF file
IHIsma Haq
Isma Haq
KAKaseb Alanazi
Kaseb Alanazi
JCJoanna Czulak
Joanna Czulak
Sabrina Di MasiSabrina Di Masi
Sabrina Di Masi
EPElena Piletska
Elena Piletska
ACALVARO GARCIA CRUZ
ALVARO GARCIA CRUZ
Sitagliptin is a hypoglycaemic agent used to reduce blood sugar levels in patients with type 2 diabetes mellitus (T2DM). Real time monitoring of sitagliptin levels is crucial to prevent overdose, which might cause liver, kidney and pancreatic diseases. As an alternative solution, a sitagliptin voltammetric sensor was fabricated using artificial receptors called electroactive molecularly imprinted polymer nanoparticles (nanoMIPs). The nanoMIP tagged with a redox probe (ferrocene) combines both the recognition and reporting functions. Traditional electrochemical sensors determine the redox activity of an analyte. Thus, they are influenced by interfering molecules and the nature of the sample. These innovative nanoMIPs allow us to easily design and customise sensors, increase their sensitivity and minimise the cross reactivity in biological samples. The present technology replaces the traditional enzyme–mediator pairs used in traditional biosensors. The polymer composition was optimized “in silico” using docking and screening methods. Nanoparticles were synthesized via free radical polymerization and a solid phase method and then characterized by infrared spectroscopy (FTIR), transmission electron microscopy (TEM) and dynamic light scattering (DLS). The specific sitagliptin nanoparticles were covalently immobilized on platinum electrodes via silane and carbodiimide chemistry. The determination of sitagliptin in human plasma by a nanoMIP sensor was assessed by differential pulse voltammetry (DPV). The sensor current response was directly related to the change in nanoMIP conformation triggered by the analyte. The optimisation of the sensor response was made by adjusting (i) the silane concentration, (ii) nanoMIP concentration, and (iii) immobilization time. The sensor measurements in plasma revealed high selectivity and a sensitivity of 32.5 ± 0.6 nA pM−1 towards sitagliptin, and the limit of detection of the fabricated sensor was found to be 0.06 pM. The sensor displayed a satisfactory performance for the determination of sitagliptin in spiked human plasma, demonstrating the potential of this technology for drug monitoring and clinical diagnosis.