Micro-blade design is an important factor in the cutting of single cells and other biological structures. This paper describes the fabrication process of three-dimensional (3D) micro-blades for the cutting of single cells in a microfluidic “guillotine” intended for fundamental wound repair and regeneration studies. Our microfluidic guillotine consists of a fixed 3D micro-blade centered in a microchannel to bisect cells flowing through. We show that the Nanoscribe two-photon polymerization direct laser writing system is capable of fabricating complex 3D micro-blade geometries. However, structures made of the Nanoscribe IP-S resin have low adhesion to silicon, and they tend to peel off from the substrate after at most two times of replica molding in poly(dimethylsiloxane) (PDMS). Our work demonstrates that the use of a secondary mold replicates Nanoscribe-printed features faithfully for at least 10 iterations. Finally, we show that complex micro-blade features can generate different degrees of cell wounding and cell survival rates compared with simple blades possessing a vertical cutting edge fabricated with conventional 2.5D photolithography. Our work lays the foundation for future applications in single cell analyses, wound repair and regeneration studies, as well as investigations of the physics of cutting and the interaction between the micro-blade and biological structures.

5 July 2021 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
SCSeth C. Cordts
Seth C. Cordts
NCNicolas Castaño
Nicolas Castaño
SKSaisneha Koppaka
Saisneha Koppaka
STSindy Tang
Sindy Tang
Generating uniform tissue microfragments is important in many applications, including disease diagnostics, drug screening, spatial-omics, and fundamental wound healing and tissue regeneration studies. Common mechanical dissection methods, such as manual mincing, are imprecise and result in fragments with a broad range in size. This work aims to develop a microscale dicing device, referred to as the “μDicer,” consisting of a hollow array of blades spaced hundreds of micrometers apart. A tissue pushed through this array is diced into many microfragments simultaneously. The focus of this paper is on the fabrication process of the μDicer using a combination of isotropic and anisotropic etching in silicon. A single silicon oxide etch mask is used in a dry silicon etcher for both a tapered etch to form the microblades, and an anisotropic etch to form the through-holes in the hollow blade array. The use of a single mask reduces the mask fabrication time by more than twofold compared with two-mask approaches often used to generate similar etch features. The etch parameters and the design of the etch mask control the blade angles and the edge profiles of the blades. Specifically, the incorporation of “notches” in the two-dimensional mask design generates three-dimensional microserrated features on the blade edges. A custom, open-source etching model is also developed to facilitate the prediction of the etch profiles. Finally, a proof-of-concept application of the μDicer to dissect soft materials and tissues is demonstrated.

27 July 2021 in Preprints.org
Verified
Preprint
Open access
PDF file
SKSaisneha Koppaka
Saisneha Koppaka
KZKevin Zhang
Kevin Zhang
MJMyra Kurosu Jalil
Myra Kurosu Jalil
LBLucas Blauch
Lucas Blauch
STSindy Tang
Sindy Tang
Micro-blade design is an important factor in the cutting of single cells and other biological structures. This paper describes the fabrication process of three dimensional (3D) micro-blades for the cutting of single cells in a microfluidic “guillotine” intended for fundamental wound repair and regeneration studies. Our microfluidic guillotine consists of a fixed 3D micro-blade centered in a microchannel to bisect cells flowing through. We show that the Nanoscribe two-photon polymerization direct laser writing system is capable of fabricating complex 3D micro-blade geometries. However, structures made of the Nanoscribe IP-S resin have low adhesion to silicon, and they tend to peel off from the substrate after at most two times of replica molding in poly(dimethylsiloxane) (PDMS). Our work demonstrates that the use of a secondary mold replicates Nanoscribe printed features faithfully for at least 10 iterations. Finally, we show that complex micro-blade features can generate different degrees of cell wounding and cell survival rates compared with simple blades possessing a vertical cutting edge fabricated with conventional 2.5D photolithography. Our work lays the foundation for future applications in single cell analyses, wound repair and regeneration studies, as well as investigations of the physics of cutting and the interaction between the micro-blade and biological structures.