Samira Aditya Kunapareddy

Dr. Samira Aditya Kunapareddy

Biomedical Materials Science, University of Mississippi Medical Center, Jackson, California, USA
orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2025 in Dental Materials
Verified
Journal Article
Closed access
JJJaccare Jauregui-Ulloa
Jaccare Jauregui-Ulloa
Samira Aditya KunapareddySamira Aditya Kunapareddy
Samira Aditya Kunapareddy
Amol V. JanorkarAmol V. Janorkar
Amol V. Janorkar
JGJason Griggs
Jason Griggs
Roach MichaelRoach Michael
Roach Michael
SMSusana Salazar Marocho
Susana Salazar Marocho

1 June 2025 in Journal of Dentistry
Verified
Journal Article
Open access
JJJaccare T. Jauregui-Ulloa
Jaccare T. Jauregui-Ulloa
BLBrooklyn N. Luke
Brooklyn N. Luke
Samira Aditya KunapareddySamira Aditya Kunapareddy
Samira Aditya Kunapareddy
JGJason A. Griggs
Jason A. Griggs
Richard Bengt PriceRichard Bengt Price
Richard Bengt Price
SMSusana Salazar Marocho
Susana Salazar Marocho
This study evaluated the effect of the light curing unit (LCU), light curing technique (LCT), and insertion technique (CIT) of resin-based composite (RBC) on the microhardness at various depths of RBC specimens. A mesio-occlusal-distal (MOD) mold was used to make samples of conventional RBC (n = 3/group) using either an incremental (I) or a bulk-fill (BF) technique. The RBC was photocured using one of three different LCUs (Bluephase Style 20i for 15 s (I) and 10 s (BF), Monet laser for 1 s (I) and 3 s (BF), and Pinkwave for 10 s (I) and 20 s (BF). The LCUs were positioned either only over the center of the mold, or at three sites (side-center-side). The Vickers microhardness was measured at different distances from the top of the sample. Four-way ANOVA and Pareto chart analysis were performed (α=0.05). All the experimental factors were significant (p ≤ 0.05). The Pinkwave produced the highest microhardness, followed by the Bluephase and Monet. Light exposure from the three sites produced higher microhardness than light exposure only at the center of the mold. The incremental technique resulted in higher microhardness than the bulk-fill technique. The depth of the RBC negatively affected the microhardness. RBC microhardness varied depending on the type of LCU used. The Pinkwave delivered the most energy and produced the highest microhardness values. To ensure uniform microhardness of the RBC, the tip of the LCU should cover all aspects of the restoration (occlusal, mesial, and distal surfaces).

14 August 2026 in Clinical Dental Journal
Verified
Journal Article
Open access
Samira Aditya KunapareddySamira Aditya Kunapareddy
Samira Aditya Kunapareddy
JJJaccare Jauregui-Ulloa
Jaccare Jauregui-Ulloa
DHDarrel Mitchell Hutto
Darrel Mitchell Hutto
SMSusana Salazar Marocho
Susana Salazar Marocho