Samuele Zoratto

Mr. Samuele Zoratto

Technische Universität Wien
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Journal of Investigative Dermatology
Verified
Journal Article
Closed access
MNMarie-Sophie Narzt
Marie-Sophie Narzt
VPVera Pils
Vera Pils
CKChristopher Kremslehenr
Christopher Kremslehenr
INIonela-Mariana Nagelreiter
Ionela-Mariana Nagelreiter
Markus SchossererMarkus Schosserer
Markus Schosserer
ILIngo Lämmermann
Ingo Lämmermann

6 July 2019 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
VWVictor Weiss
Victor Weiss
RPRonja Pogan
Ronja Pogan
Samuele ZorattoSamuele Zoratto
Samuele Zoratto
KBKevin M. Bond
Kevin M. Bond
PBPascale Boulanger
Pascale Boulanger
GAGünter Allmaier
Günter Allmaier
(Bio-)nanoparticle analysis employing a nano-electrospray gas-phase electrophoretic mobility molecular analyzer (native nES GEMMA) also known as nES differential mobility analyzer (nES DMA) is based on surface-dry analyte separation at ambient pressure. Based on electrophoretic principles, single-charged nanoparticles are separated according to their electrophoretic mobility diameter (EMD) corresponding to the particle size for spherical analytes. Subsequently, it is possible to correlate the (bio-)nanoparticle EMDs to their molecular weight (MW) yielding a corresponding fitted curve for an investigated analyte class. Based on such a correlation, (bio-)nanoparticle MW determination via its EMD within one analyte class is possible. Turning our attention to icosahedral, non-enveloped virus-like particles (VLPs), proteinaceous shells, we set up an EMD/MW correlation. We employed native electrospray ionization mass spectrometry (native ESI MS) to obtain MW values of investigated analytes, where possible, after extensive purification. We experienced difficulties in native ESI MS with time-of-flight (ToF) detection to determine MW due to sample inherent characteristics, which was not the case for charge detection (CDMS). nES GEMMA exceeds CDMS in speed of analysis and is likewise less dependent on sample purity and homogeneity. Hence, gas-phase electrophoresis yields calculated MW values in good approximation even when charge resolution was not obtained in native ESI ToF MS. Therefore, both methods-native nES GEMMA-based MW determination via an analyte class inherent EMD/MW correlation and native ESI MS-in the end relate (bio-)nanoparticle MW values. However, they differ significantly in, e.g., ease of instrument operation, sample and analyte handling, or costs of instrumentation. Graphical abstract

24 December 2020 in Vaccines
Verified
Journal Article
Open access
PDF file
RPRonja Pogan
Ronja Pogan
VWVictor Weiss
Victor Weiss
KBKevin Bond
Kevin Bond
JDJasmin Dülfer
Jasmin Dülfer
CKChristoph Krisp
Christoph Krisp
CUCharlotte Uetrecht
Charlotte Uetrecht
Noroviruses cause immense sporadic gastroenteritis outbreaks worldwide. Emerging genotypes, which are divided based on the sequence of the major capsid protein VP1, further enhance this public threat. Self-assembling properties of the human norovirus major capsid protein VP1 are crucial for using virus-like particles (VLPs) for vaccine development. However, there is no vaccine available yet. Here, VLPs from different variants produced in insect cells were characterized in detail using a set of biophysical and structural tools. We used native mass spectrometry, gas-phase electrophoretic mobility molecular analysis, and proteomics to get clear insights into particle size, structure, and composition, as well as stability. Generally, noroviruses have been known to form mainly T = 3 particles. Importantly, we identified a major truncation in the capsid proteins as a likely cause for the formation of T = 1 particles. For vaccine development, particle production needs to be a reproducible, reliable process. Understanding the underlying processes in capsid size variation will help to produce particles of a defined capsid size presenting antigens consistent with intact virions. Next to vaccine production itself, this would be immensely beneficial for bio-/nano-technological approaches using viral particles as carriers or triggers for immunological reactions.

1 January 2022 in Journal of Investigative Dermatology
Verified
Journal Article
Closed access
MSMichaela Sochorová
Michaela Sochorová
KVKaterina Vavrova
Katerina Vavrova
MFMaria Fedorova
Maria Fedorova
ZNZhixu Ni
Zhixu Ni
DSDenise Slenter
Denise Slenter
FGFlorian Gruber
Florian Gruber

13 June 2023 in Viruses
Verified
Journal Article
Open access
PDF file
Samuele ZorattoSamuele Zoratto
Samuele Zoratto
THThomas Heuser
Thomas Heuser
GFGernot Friedbacher
Gernot Friedbacher
RPRobert Pletzenauer
Robert Pletzenauer
MGMichael Graninger
Michael Graninger
VWVictor Weiss
Victor Weiss
Gas-phase electrophoresis on a nano-Electrospray Gas-phase Electrophoretic Mobility Molecular Analyzer (nES GEMMA) separates single-charged, native analytes according to the surface-dry particle size. A volatile electrolyte, often ammonium acetate, is a prerequisite for electrospraying. Over the years, nES GEMMA has demonstrated its unique capability to investigate (bio-)nanoparticle containing samples in respect to composition, analyte size, size distribution, and particle numbers. Virus-like particles (VLPs), being non-infectious vectors, are often employed for gene therapy applications. Focusing on adeno-associated virus 8 (AAV8) based VLPs, we investigated the response of these bionanoparticles to pH changes via nES GEMMA as ammonium acetate is known to exhibit these changes upon electrospraying. Indeed, slight yet significant differences in VLP diameters in relation to pH changes are found between empty and DNA-cargo-filled assemblies. Additionally, filled VLPs exhibit aggregation in dependence on the applied electrolyte’s pH, as corroborated by atomic force microscopy. In contrast, cryogenic transmission electron microscopy did not relate to changes in the overall particle size but in the substantial particle’s shape based on cargo conditions. Overall, we conclude that for VLP characterization, the pH of the applied electrolyte solution has to be closely monitored, as variations in pH might account for drastic changes in particles and VLP behavior. Likewise, extrapolation of VLP behavior from empty to filled particles has to be carried out with caution.

26 November 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
RPRonja Pogan
Ronja Pogan
VWVictor U. Weiss
Victor U. Weiss
KBKevin Bond
Kevin Bond
JDJasmin Duelfer
Jasmin Duelfer
CKChristoph Krisp
Christoph Krisp
CUCharlotte Uetrecht
Charlotte Uetrecht
Noroviruses cause immense sporadic gastroenteritis outbreaks worldwide. Emerging genotypes, which are divided based on VP1 sequence, further enhance this public threat. Self-assembling properties of the human norovirus major capsid protein VP1 are crucial for using virus-like particles (VLPs) for vaccine development. However, there is no vaccine available yet. Here, VLPs from different variants produced in insect cells are characterized in detail using a set of biophysical and structural tools. We are using native mass spectrometry, gas-phase electrophoretic mobility molecular analysis and proteomics to get clear insights into particle size, structure, composition as well as stability. Generally, noroviruses have been known to form mainly T =3 particles. Importantly, we identify a major truncation in the capsid proteins as a likely cause for the formation of merely T =1 particles. For vaccine development, particle production needs to be a reproducible, reliable process. Understanding the underlying processes in capsid size variation will help to produce particles of a defined capsid size presenting antigens consistent with intact virions. Next to vaccine production itself, this would be immensely beneficial for bio-/nano-technological approaches using viral particles as carriers or triggers for immunological reactions.