The dependence of distributed generations (DGs) on climate conditions and fluctuating load demands are the challenges for the implementation of battery energy storage systems (BESSs) in islanded microgrids. BESS participation in system frequency regulation becomes one of the solutions to those challenges. Frequency regulation by BESS can be realized by applying the load-frequency control (LFC) in BESS. However, this participation clearly poses problems for the battery state of charge (SOC), as the battery is often overcharged or undercharged. In this paper, a control that maintains SOC at a certain level is introduced. This control strategy focuses on the battery operation function, which is determined from five control scenarios. All scenarios are achieved by applying the droop reference shifting method in the LFC to allow battery operation change. Control verification is carried out on an islanded microgrid system that experiences load demand changes and photovoltaic (PV) output power changes. The test results show that the SOC is maintained at 45–75% by applying load and PV power variations. The results correspond to the predetermined criteria control.
The application of battery energy storage (BES) in microgrid systems has attracted much attention in recent years. It is because the BES is able to store excess power and discharge its power when needed. In islanded microgrid systems, BES is starting to be considered as a unit that can regulate the system frequency. The control used in the BES to display frequency regulation performance is called load-frequency control (LFC). However, this participation resulted in the large size of the battery and high expansion planning cost. In this paper, an advanced LFC control that has frequency limitation compared to traditional LFC is proposed. The proposed control implies droop control as the base and has frequency limitations. Compared to the traditional LFC, the proposed control can reduce the system expansion planning costs. A performance simulation was done to validate battery performance. The results of the numerical simulation showed that the proposed control participated in reducing the operation cost. It directly led to a reduction in the expansion planning cost. A study of battery selection was conducted to draw the practicality of the BES sizing solutions.
Electricity in rural area of Indonesia is mostly in small-scale with diesel generator as the main power source. These diesel generators are mostly in the latter stage of operational age, thus have limited capability and poor performance. Microgrid has been introduced lately, as a system to integrate more renewable energy sources to the existing power system. Photovoltaic (PV) source is one of the most popular renewable energy source which is utilized by microgrid. However, the fluctuating characteristic of microgrid operation and the intermittent characteristic of PV are making it harder for diesel generator to maintain the stability of the system. This situation might lead to further diesel generator performance degradation, causing operational and maintenance costs to rise. This research proposes a microgrid concept consisted of PV, diesel generator, and battery, aiming to minimize the impact for diesel generator caused by PV integration. Droop control is utilized to enable load sharing between diesel generator and PV source through grid-connected inverter. This scheme will enable the PV and inverter to participate in maintaining system operation and ease the operation of diesel generator. A battery energy storage system is introduced as a buffer to further enhancing system stability. It can be shown that under this scheme a microgrid with PV is able to actively participate in maintaining grid condition by sharing load with diesel generator, assisted by the battery as a buffer.