Sanyogita Manu

Dr. Sanyogita Manu

orcid
Postdoctoral Fellow, Carleton University & University of Tor...

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Building and Environment
Verified
Journal Article
Open access
Sanyogita ManuSanyogita Manu
Sanyogita Manu
YSYash Shukla
Yash Shukla
RRRajan Rawal
Rajan Rawal
LTLeena Thomas
Leena Thomas
RDRichard de Dear
Richard de Dear
India is witnessing unprecedented growth trends in building construction, particularly office spaces. Indian offices are designed to operate at 22.5 ± 1 °C all year round to meet the stringent “Class A” specifications outlined by international standards in the absence of an India-specific comfort standard. This paper proposes an India Model for Adaptive Comfort – IMAC – based on the field surveys administered in 16 buildings in three seasons and five cities, representative of five Indian climate zones. A total of 6330 responses were gathered from naturally ventilated, mixed mode and air-conditioned office buildings using instantaneous thermal comfort surveys.Occupants in naturally ventilated Indian offices were found to be more adaptive than the prevailing ASHRAE and EN models would suggest. According to the IMAC model, neutral temperature in naturally ventilated buildings varies from 19.6 to 28.5 °C for 30-day outdoor running mean air temperatures ranging from 12.5 to 31 °C. This is the first instance where a study proposes a single adaptive model for mixed mode buildings asserting its validity for both naturally ventilated and air-conditioned modes of operation in the building, with neutral temperature varying from 21.5 to 28.7 °C for 13–38.5 °C range of outdoor temperatures. For air-conditioned buildings, Fanger's static PMV model was found to consistently over-predict the sensation on the warmer side of the 7-point sensation scale

1 January 2019 in Building and Environment
Verified
Journal Article
Closed access
Sanyogita ManuSanyogita Manu
Sanyogita Manu
GBGail Brager
Gail Brager
RRRajan Rawal
Rajan Rawal
AGAngela Geronazzo
Angela Geronazzo
DKDevarsh Kumar
Devarsh Kumar

10 October 2018 in Building Research & Information
Verified
Journal Article
Open access
Rajat GuptaRajat Gupta
Rajat Gupta
MGMatt Gregg
Matt Gregg
Sanyogita ManuSanyogita Manu
Sanyogita Manu
PVPrasad Vaidya
Prasad Vaidya
MDMaaz Dixit
Maaz Dixit
The green building movement in India is lacking an important link: ensuring that the design intent of such buildings is actually realized. This paper undertakes an exploratory investigation to develop and test a customized building performance evaluation (BPE) approach (I-BPE framework) for the Indian context. As academia is considered to be an initial primary outlet of BPE, a survey of experts is conducted to investigate the drivers and barriers for implementing BPE-based methods in educational curricula. The I-BPE approach is tested in a case study building to gain insights for refining the underlying methods and processes for conducting further BPE studies in the context of India. The expert survey reveals the lack of trained people for teaching BPE as a key challenge to its adoption, implying that trained people are needed as much as frameworks. To enable widespread adoption of I-BPE in India, what will be necessary is a new cadre of building performance evaluators who can be trained (or up-skilled) through formal or continuing education. This will need to be driven by both policy (energy code) and market transformation (‘green’ rating systems). A series of delivery routes are suggested to enable rapid and deeper learning.


23 October 2024 in Building and Environment
Verified
Journal Article
Open access
Sanyogita ManuSanyogita Manu
Sanyogita Manu
ARAdam Rysanek
Adam Rysanek

19 September 2024 in Buildings
Verified
Journal Article
Open access
PDF file
Sanyogita ManuSanyogita Manu
Sanyogita Manu
ARAdam Rysanek
Adam Rysanek
While field research in indoor air quality (IAQ) increasingly uses large numbers of low-cost sensors, detailed validation of each sensor is becoming infeasible, ignored, or undeclared. Questions remain about whether these sensors meet manufacturer or third-party specifications and whether their utility improves with some validation, even under imperfect conditions. This study details the outcomes of a co-location experiment with 87 low-cost IAQ monitors, conducted with the objective of verifying their performance in measuring total volatile organic compounds (tVOCs), particulate matter 2.5 (PM2.5), carbon dioxide (CO2), temperature, and relative humidity. The monitors were installed next to professional-grade reference IAQ instruments in an office with controlled ventilation. A mixed validation methodology was used, involving outlier detection, uncertainty quantification, and performance metric calculations. Results showed that CO2, temperature, and humidity sensors reliably met manufacturer specifications, while tVOC sensors had significant accuracy issues, deviating by up to 79% from reference measurements—substantially more than the stated uncertainty of ±20%. PM2.5 sensors were more consistent but had an error margin of ±27%, compared to the stated ±15%. A total of 5 of the 87 sensors (5.7%) were outliers for at least one IAQ indicator. Despite the need for further long-term validation, this study highlights the importance of performing an experimental evaluation of low-cost IAQ monitors before field deployment.