The effect of helix angle and pitch ratio of helical surface disc turbulators on the thermal performance of double pipe heat exchanger are discussed in this study. Tests are performed with air as working fluid for different pitch ratios, numerous helix angles, and various Reynolds number. Water and air are allowed to flow along inner tube and through annulus, respectively. In each case, the thermal enhancement factor is observed to be higher than unit value. Smallest pitch ratio and highest helix angle yield highest thermo-hydraulic performance of 1.39 at Re = 3,500. Correlations are developed for various parameters.
The heat transfer characteristic in the annulus of a double pipe heat exchanger using the corrugated outer tube is analyzed with three corrugation pitches (10, 20, and 30 mm), three diameter ratios (0.53, 0.44, and 0.40), and Reynolds number range 3500–10,500. Tests are conducted for air as a working fluid. The heat exchanger with least pitch and diameter ratio is found to exhibit the highest Nusselt number and pressure drop. The maximum enhancement in the Nusselt number and friction factor is found to be 71% and 81%, respectively. In addition, correlations have been developed for Nusselt number, friction factor, and thermal performance factor.
Designing an effective cooling system for high-power-density in-wheel motors of electric vehicles is required to avoid the irreversible demagnetization of the permanent magnet due to a rise in its temperature. In this study, a water-cooling channel was used between the stator and housing to evaluate the cooling performance of a 25 kW in-wheel motor utilizing the commercially available software Ansys Fluent 19.2. Initially, cooling channels with a single or pair of vortex generators have been used with varying heights for pressure drop evaluation considering the allowable pressure drop of 0.7 bar for a water pump. The results indicates that both a single and a pair of vortex generators satisfy the limit of a pressure drop at the height of 4 and 3 mm, respectively, and the cooling performances of two vortex generators were evaluated at these heights. It has been found that the cooling performance of a permanent magnet is enhanced by 4.1% and 6.5% using a single and a pair of vortex generators, respectively, compared to the cooling channel without a vortex generator. Furthermore, considering the ram air effect on water-cooling channels of in-wheel motors under high-speed conditions, the temperature of the permanent magnet is decreased by about 2.1 °C and was found to be 148.8 °C under the temperature limit of demagnetization of the permanent magnet.