Sebastián Mateo Valladares

Mr. Sebastián Mateo Valladares

Yachay Tech University
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Talía TeneTalía Tene
Talía Tene
Stefano BellucciStefano Bellucci
Stefano Bellucci
MGMarco Guevara
Marco Guevara
EVEdwin Viteri
Edwin Viteri
MAMelvin Arias
Melvin Arias
Cristian Vacacela GomezCristian Vacacela Gomez
Cristian Vacacela Gomez
Reduced graphene oxide (rGO) is one of the most well-known graphene derivatives, which, due to its outstanding physical and chemical properties as well as its oxygen content, has been used for wastewater treatment technologies. Particularly, extra functionalized rGO is widely preferred for treating wastewater containing dyes or heavy metals. Nevertheless, the use of non-extra functionalized (pristine) rGO for the removal of cationic pollutants is not explored in detail or is ambiguous. Herein, pristine rGO—prepared by an eco-friendly protocol—is used for the removal of cationic pollutants from water, i.e., methylene blue (MB) and mercury-(II) (Hg-(II)). This work includes the eco-friendly synthesis process and related spectroscopical and morphological characterization. Most importantly, the investigated rGO shows an adsorption capacity of 121.95 mg g−1 for MB and 109.49 mg g−1 for Hg (II) at 298 K. A record adsorption time of 30 min was found for MB and 20 min for Hg (II) with an efficiency of about 89% and 73%, respectively. The capture of tested cationic pollutants on rGO exhibits a mixed physisorption–chemisorption process. The present work, therefore, presents new findings for cationic pollutant adsorbent materials based on oxidized graphenes, providing a new perspective for removing MB molecules and Hg(II) ions.

20 August 2024 in International Journal of Modern Physics A
Verified
Journal Article
Closed access
VAVicente A. Arévalo
Vicente A. Arévalo
SVSebastián Mateo Valladares
Sebastián Mateo Valladares
CRClara Rojas
Clara Rojas

3 February 2023 in arXiv
Verified
Preprint
Open access
PDF file
SVSebastián Mateo Valladares
Sebastián Mateo Valladares
CRClara Rojas
Clara Rojas
In this article, we solve the Duffin--Kemmer--Petiau (DKP) equation in the presence of hyperbolic tangent potential for spin-one particles. By partitioning the spin-one spinor, we show that the DKP equation is equivalent to the Klein--Gordon equation formalism. The scattering solutions are derived in terms of hypergeometric functions. The reflection $R$ and transmission $T$ coefficients are calculated in terms of the Gamma functions. The results show the presence of the superradiance phenomenon when $R$ for a specific region in the potential becomes greater than one.

25 August 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PTPablo Torres-Sánchez
Pablo Torres-Sánchez
VBVictor Babiano-Suarez
Victor Babiano-Suarez
JCJavier Balibrea Correa
Javier Balibrea Correa
BGBernardo Gameiro
Bernardo Gameiro
JLJorge Lerendegui-Marco
Jorge Lerendegui-Marco
CDCésar Domingo-Pardo
César Domingo-Pardo
Objective. Boron neutron capture therapy (BNCT) requires accurate knowledge of the boron distribution during treatment to enable reliable dosimetry and treatment verification. Compton imaging of the 478 keV prompt gamma rays emitted following neutron capture by 10 B has been proposed as a promising technique for real-time boron monitoring. This work aims to experimentally evaluate the feasibility of Compton imaging under clinically relevant boron concentrations and realistic neutron-induced background conditions. Approach. A dedicated experimental campaign was performed at the Institut Laue-Langevin (ILL, Grenoble, France) using the i-TED Compton camera array. Three experimental configurations with progressively increasing neutron-induced background were investigated, including a water phantom containing 65 ppm 10 B, representative of typical tumor concentrations during BNCT. Experimental measurements were complemented by detailed Geant4 Monte Carlo simulations to interpret detector performance, identify current limitations, and assess potential detector improvements. Main results. The experiments demonstrate, for the first time, Compton imaging of 10 B at a clinically relevant concentration of 65 ppm under neutron irradiation. The reconstructed 478 keV gamma-ray emission was correctly localized with a spatial resolution of 22 mm (FWHM) and a signal-to-background ratio of 6.4. The study also identifies the principal limitations affecting detector performance, namely high count-rate effects and contamination from back-scattered Compton events. Dedicated analyses and simulations show that optimized event filtering substantially mitigates image degradation, while future detector developments based on pixelated scintillator arrays and improved timing capabilities are expected to significantly enhance performance under BNCT operating conditions. Significance. These results constitute the first experimental validation of Compton imaging for boron monitoring at clinically relevant concentrations and demonstrate the potential of the technique for real-time BNCT dosimetry. The identified detector improvements provide a technically grounded pathway towards clinical implementation of gamma-ray imaging-based dose monitoring in BNCT.