Selene Tomassini

Dr. Selene Tomassini

Information Engineering and Computer Science, Università degli Studi di Trento, Trento, Trentino-Alto Adige, Italy
orcid
Assistant professor @UNITN

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 November 2021 in IEEE Access
Verified
Journal Article
Open access
PSPaolo Sernani
Paolo Sernani
NFNicola Falcionelli
Nicola Falcionelli
Selene TomassiniSelene Tomassini
Selene Tomassini
PCPaolo Contardo
Paolo Contardo
Aldo Franco DragoniAldo Franco Dragoni
Aldo Franco Dragoni
Following the growing availability of video surveillance cameras and the need for techniques to automatically identify events in video footages, there is an increasing interest towards automatic violence detection in videos. Deep learning-based architectures, such as 3D Convolutional Neural Networks, demonstrated their capability of extracting spatio-temporal features from videos, being effective in violence detection. However, friendly behaviours or fast moves such as hugs, small hits, claps, high fives, etc., can still cause false positives, interpreting a harmless action as violent. To this end, we present three deep-learning based models for violence detection and test them on the AIRTLab dataset, a novel dataset designed to check the robustness of algorithms against false positives. The objective is twofold: on one hand, we compute accuracy metrics on the three proposed models (two are based on transfer learning and one is trained from scratch), building a baseline of metrics for the AIRTLab dataset; on the other hand, we validate the capability of the proposed dataset of challenging the robustness to false positives. The results of the proposed models are in line with the scientific literature, in terms of accuracy, with transfer learning-based networks exhibiting better generalization capabilities than the trained from scratch network. Moreover, the tests highlighted that most of the classification errors concern the identification of non-violent clips, validating the design of the proposed dataset. Finally, to demonstrate the significance of the proposed models, the paper presents a comparison with the related literature, as well as with models based on well-established pre-trained 2D Convolutional Neural Networks 2D CNNs. Such comparison highlights that 3D models get better accuracy performance than time distributed 2D CNNs (merged with a recurrent model) in processing the spatio-temporal features of video clips. The source code of the experiments and the AIRTLab dataset are available in public repositories.

6 June 2022 in Computers in Biology and Medicine
Verified
Journal Article
Open access
Selene TomassiniSelene Tomassini
Selene Tomassini
NFNicola Falcionelli
Nicola Falcionelli
PSPaolo Sernani
Paolo Sernani
Laura BurattiniLaura Burattini
Laura Burattini
Aldo Franco DragoniAldo Franco Dragoni
Aldo Franco Dragoni
Lung cancer is among the deadliest cancers. Besides lung nodule classification and diagnosis, developing non-invasive systems to classify lung cancer histological types/subtypes may help clinicians to make targeted treatment decisions timely, having a positive impact on patients' comfort and survival rate. As convolutional neural networks have proven to be responsible for the significant improvement of the accuracy in lung cancer diagnosis, with this survey we intend to: show the contribution of convolutional neural networks not only in identifying malignant lung nodules but also in classifying lung cancer histological types/subtypes directly from computed tomography data; point out the strengths and weaknesses of slice-based and scan-based approaches employing convolutional neural networks; and highlight the challenges and prospective solutions to successfully apply convolutional neural networks for such classification tasks. To this aim, we conducted a comprehensive analysis of relevant Scopus-indexed studies involved in lung nodule diagnosis and cancer histology classification up to January 2022, dividing the investigation in convolutional neural network-based approaches fed with planar or volumetric computed tomography data. Despite the application of convolutional neural networks in lung nodule diagnosis and cancer histology classification is a valid strategy, some challenges raised, mainly including the lack of publicly-accessible annotated data, together with the lack of reproducibility and clinical interpretability. We believe that this survey will be helpful for future studies involved in lung nodule diagnosis and cancer histology classification prior to lung biopsy by means of convolutional neural networks.

1 December 2020 in Data in Brief
Verified
Journal Article
Open access
MBMiriana Bianculli
Miriana Bianculli
NFNicola Falcionelli
Nicola Falcionelli
PSPaolo Sernani
Paolo Sernani
Selene TomassiniSelene Tomassini
Selene Tomassini
PCPaolo Contardo
Paolo Contardo
Aldo Franco DragoniAldo Franco Dragoni
Aldo Franco Dragoni
The automatic detection of violence and crimes in videos is gaining attention, specifically as a tool to unburden security officers and authorities from the need to watch hours of footages to identify event lasting few seconds. So far, most of the available datasets was composed of few clips, in low resolution, often built on too specific cases (e.g. hockey fight). While high resolution datasets are emerging, there is still the need of datasets to test the robustness of violence detection techniques to false positives, due to behaviours which might resemble violent actions. To this end, we propose a dataset composed of 350 clips (MP4 video files, 1920 × 1080 pixels, 30 fps), labelled as non-violent (120 clips) when representing non-violent behaviours, and violent (230 clips) when representing violent behaviours. In particular, the non-violent clips include behaviours (hugs, claps, exulting, etc.) that can cause false positives in the violence detection task, due to fast movements and the similarity with violent behaviours. The clips were performed by non-professional actors, varying from 2 to 4 per clip.

9 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MHD JAFAR MORTADAMHD JAFAR MORTADA
MHD JAFAR MORTADA
Selene TomassiniSelene Tomassini
Selene Tomassini
HAHaidar Anbar
Haidar Anbar
Micaela MorettiniMicaela Morettini
Micaela Morettini
Laura BurattiniLaura Burattini
Laura Burattini
Agnese SbrolliniAgnese Sbrollini
Agnese Sbrollini
Knowledge about the anatomical structures of the left heart, specifically the atrium (LA) and ventricle (i.e., endocardium—Vendo—and epicardium—LVepi) is essential for the evaluation of cardiac functionality. Manual segmentation of cardiac structures from echocardiography is the baseline reference, but results are user-dependent and time-consuming. With the aim of supporting clinical practice, this paper presents a new deep-learning (DL)-based tool for segmenting anatomical structures of the left heart from echocardiographic images. Specifically, it was designed as a combination of two convolutional neural networks, the YOLOv7 algorithm and a U-Net, and it aims to automatically segment an echocardiographic image into LVendo, LVepi and LA. The DL-based tool was trained and tested on the Cardiac Acquisitions for Multi-Structure Ultrasound Segmentation (CAMUS) dataset of the University Hospital of St. Etienne, which consists of echocardiographic images from 450 patients. For each patient, apical two- and four-chamber views at end-systole and end-diastole were acquired and annotated by clinicians. Globally, our DL-based tool was able to segment LVendo, LVepi and LA, providing Dice similarity coefficients equal to 92.63%, 85.59%, and 87.57%, respectively. In conclusion, the presented DL-based tool proved to be reliable in automatically segmenting the anatomical structures of the left heart and supporting the cardiological clinical practice.

26 May 2022 in Information
Verified
Journal Article
Open access
PDF file
APAndrea Polenta
Andrea Polenta
Selene TomassiniSelene Tomassini
Selene Tomassini
NFNicola Falcionelli
Nicola Falcionelli
PCPaolo Contardo
Paolo Contardo
Aldo Franco DragoniAldo Franco Dragoni
Aldo Franco Dragoni
PSPaolo Sernani
Paolo Sernani
The developments in the internet of things (IoT), artificial intelligence (AI), and cyber-physical systems (CPS) are paving the way to the implementation of smart factories in what is commonly recognized as the fourth industrial revolution. In the manufacturing sector, these technological advancements are making Industry 4.0 a reality, with data-driven methodologies based on machine learning (ML) that are capable of extracting knowledge from the data collected by sensors placed on production machines. This is particularly relevant in plastic injection molding, with the objective of monitoring the quality of molded products from the parameters of the production process. In this regard, the main contribution of this paper is the systematic comparison of ML techniques to predict the quality classes of plastic molded products, using real data collected during the production process. Specifically, we compare six different classifiers on the data coming from the production of plastic road lenses. To run the comparison, we collected a dataset composed of the process parameters of 1451 road lenses. On such samples, we tested a multi-class classification, providing a statistical analysis of the results as well as of the importance of the input features. Among the tested classifiers, the ensembles of decision trees, i.e., random forest and gradient-boosted trees (GBT), achieved 95% accuracy in predicting the quality classes of molded products, showing the viability of the use of ML-based techniques for this purpose. The collected dataset and the source code of the experiments are available in a public, open-access repository, making the presented research fully reproducible.

1 January 2019 in Mathematical Biosciences and Engineering
Verified
Journal Article
Open access
PDF file
Selene TomassiniSelene Tomassini
Selene Tomassini
ASAnnachiara Strazza
Annachiara Strazza
ASAgnese Sbrollini
Agnese Sbrollini
IMIlaria Marcantoni
Ilaria Marcantoni
MMMicaela Morettini
Micaela Morettini
Laura BurattiniLaura Burattini
Laura Burattini
Fetal heart rate (FHR) monitoring can serve as a benchmark to identify high-risk fetuses. Fetal phonocardiogram (FPCG) is the recording of the fetal heart sounds (FHS) by means of a small acoustic sensor placed on maternal abdomen. Being heavily contaminated by noise, FPCG processing implies mandatory filtering to make FPCG clinically usable. Aim of the present study was to perform a comparative analysis of filters based on Wavelet transform (WT) characterized by different combinations of mothers Wavelet and thresholding settings. By combining three mothers Wavelet (4th-order Coiflet, 4th-order Daubechies and 8th-order Symlet), two thresholding rules (Soft and Hard) and three thresholding algorithms (Universal, Rigorous and Minimax), 18 different WT-based filters were obtained and applied to 37 simulated and 119 experimental FPCG data (PhysioNet/PhysioBank). Filters performance was evaluated in terms of reliability in FHR estimation from filtered FPCG and noise reduction quantified by the signal-to-noise ratio (SNR). The filter obtained by combining the 4th-order Coiflet mother Wavelet with the Soft thresholding rule and the Universal thresholding algorithm was found to be optimal in both simulated and experimental FPCG data, since able to maintain FHR with respect to reference (138.7[137.7; 140.8] bpm vs. 140.2[139.7; 140.7] bpm, P > 0.05, in simulated FPCG data; 139.6[113.4; 144.2] bpm vs. 140.5[135.2; 146.3] bpm, P > 0.05, in experimental FPCG data) while strongly incrementing SNR (25.9[20.4; 31.3] dB vs. 0.7[-0.2; 2.9] dB, P < 10-14, in simulated FPCG data; 22.9[20.1; 25.7] dB vs. 15.6[13.8; 16.7] dB, P < 10-37, in experimental FPCG data). In conclusion, the WT-based filter obtained combining the 4th-order Coiflet mother Wavelet with the thresholding settings constituted by the Soft rule and the Universal algorithm provides the optimal WT-based filter for FPCG filtering according to evaluation criteria based on both noise and clinical features.