Senthil Selvan Subramanian

Prof. Dr. Senthil Selvan Subramanian

Department of Civil Engineering, SRM Institute of Science and Technology-Kattankulathur, Chengalpattu, India
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Buildings
Verified
Journal Article
Open access
PDF file
FDFLORENCE MORE D
FLORENCE MORE D
Senthil Selvan SubramanianSenthil Selvan Subramanian
Senthil Selvan Subramanian
Numerous studies have been conducted recently on fibre reinforced concrete (FRC), a material that is frequently utilized in the building sector. The utilization of FRC has grown in relevance recently due to its enhanced mechanical qualities over normal concrete. Due to increased environmental degradation in recent years, natural fibres were developed and research is underway with the goal of implementing them in the construction industry. In this work, several natural and artificial fibres, including glass, carbon, steel, jute, coir, and sisal fibres are used to experimentally investigate the mechanical and durability properties of fibre-reinforced concrete. The fibres were added to the M40 concrete mix with a volumetric ratio of 0%, 0.5%, 1.0%, 1.5%, 2.0% and 2.5%. The compressive strength of the conventional concrete and fibre reinforced concrete with the addition of 1.5% steel, 1.5% carbon, 1.0% glass, 2.0% coir, 1.5% jute and 1.5% sisal fibres were 4.2 N/mm2, 45.7 N/mm2, 41.5 N/mm2, 45.7 N/mm2, 46.6 N/mm2, 45.7 N/mm2 and 45.9 N/mm2, respectively. Comparing steel fibre reinforced concrete to regular concrete results in a 13.69% improvement in compressive strength. Similarly, the compressive strengths were increased by 3.24%, 13.69%, 15.92%, 13.68% and 14.18% for carbon, glass, coir, jute, and sisal fibre reinforced concrete respectively when equated with plain concrete. With the optimum fraction of fibre reinforced concrete, mechanical and durability qualities were experimentally investigated. A variety of durability conditions, including the Rapid Chloride Permeability Test, water absorption, porosity, sorptivity, acid attack, alkali attack, and sulphate attack, were used to study the behaviour of fiber reinforced concrete. When compared to conventional concrete, natural fibre reinforced concrete was found to have higher water absorption and sorptivity. The rate of acid and chloride attacks on concrete reinforced with natural fibres was significantly high. The artificial fibre reinforced concrete was found to be more efficient than the natural fibre reinforced concrete. The load bearing capacity, anchorage and the ductility of the concrete improved with the addition of fibres. According to the experimental findings, artificial fibre reinforced concrete can be employed to increase the structure’s strength and longevity as well as to postpone the propagation of cracks. A microstructural analysis of concrete was conducted to ascertain its morphological characteristics.


3 December 2015 in Indian Journal of Science and Technology
Verified
Journal Article
Open access
PDF file
BVB. Vijaya
B. Vijaya
Senthil Selvan SubramanianSenthil Selvan Subramanian
Senthil Selvan Subramanian
Comparative Study on the Strength and Durability Properties of Concrete with Manufactured Sand

6 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
FDFLORENCE MORE D
FLORENCE MORE D
Senthil Selvan SubramanianSenthil Selvan Subramanian
Senthil Selvan Subramanian
The exceptional structural strength and low cost of steel-concrete composite columns make them a popular choice for civil engineering structures. Numerous forms of composite columns, including steel tubes filled with concrete, have been produced recently in response to various construction situations. Cold-formed steel tubular columns with concrete filling have higher strength and ductility due to their capacity to withstand inner buckling and postpone outward buckling. The objective of this research is to determine the ductile and strength performance of composite columns containing various forms of fibre-reinforced concrete when subjected to axial compression. Several different kinds of fibre-reinforced concrete (FRC) are employed as additives in hollow steel columns, including steel FRC, carbon FRC, glass FRC, coir FRC, jute FRC, and sisal FRC. Axial compression tests were performed on 24 columns, including three hollow steel columns and 21 composite columns. Three distinct slenderness ratios were developed and used. Axial bearing capacity, compressive stress-strain curves, ductility, peak strain, axial shortening, and toughness were among the topics covered by the axial compression test. Experimental findings demonstrated that all conventional composite columns experienced failure through overall buckling, Local buckling and crushing of concrete infill, which was transformed into more ductile failure using fibre-reinforced concrete infills. The test results revealed that fibre-reinforced concrete-infilled steel columns outperformed conventional composite columns in terms of strength, ductility, and energy absorption capacity. The percentage increase in load-carrying capacity was observed as 203.88%, 193.48% and 190.03% when compared to hollow cold-formed steel tubular columns in medium, short and stub columns, respectively. Under assessment of stub, short, and medium columns, the load-strain plots demonstrated that the steel fibre-reinforced concrete in-filled columns performed well in terms of ductility. Localized buckling and crushing of the concrete infill caused the composite columns with low slenderness ratios to fail. In contrast, concrete-filled steel tube columns with higher slenderness ratios showed column failure through the overall buckling of the composite column.

18 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
PSPradeep Sivanantham
Pradeep Sivanantham
Senthil Selvan SubramanianSenthil Selvan Subramanian
Senthil Selvan Subramanian
SSSatyanarayanan Kachabeswara Srinivasan
Satyanarayanan Kachabeswara Srinivasan
G.Beulah Gnana AnanthiG.Beulah Gnana Ananthi
G.Beulah Gnana Ananthi
Krishanu RoyKrishanu Roy
Krishanu Roy
When compared to traditional reinforced concrete constructions on level surfaces, buildings situated on hills with slopes require additional consideration, particularly when seismic loading is an important factor. In hilly slopes, the ground-level columns of structures have different heights due to the nature of the slope, which leads to a short column effect. This paper represents an experimental and analytical investigation of the behaviour of reinforced concrete frames and their response in sloped regions of hills, in which global retrofitting techniques were adopted by providing solid infill in the short column effect zone for the columns in the same storey of differentheights. Numerical analysis was conducted on how infill affected the short column effect under lateral cyclic loads. It was discovered that compared to bare reinforced concrete frames, masonry infill greatly increased the lateral load-carrying capacity by up to 50%. In the meantime, the frame’s ability to dissipate energy increased linearly. After infill was added to the frame with the short column effect, the reinforced concrete structure’s different reactions, including ultimate load displacement, crack pattern, energy dissipation, and energy absorption, were examined. With the addition of a solid infill, the reinforced concrete structure’s lateral strength and energy dissipation capacity were increased by 2.45 times. The damage development on the reinforced concrete frame with infill and the short column effect was less impacted by lateral stress than the reinforced concrete frame without infill.

1 January 2024 in Matéria (Rio de Janeiro)
Verified
Journal Article
Open access
PDF file
CGChristo George
Christo George
Senthil Selvan SubramanianSenthil Selvan Subramanian
Senthil Selvan Subramanian
This study delves into the utilization of advanced materials to enhance the mechanical characteristics and longevity of concrete structures, with a specific focus on the performance and design of beams composed of light gauge steel hollow sections (LGSHS) filled with steel fiber-reinforced concrete (SFRC) under flexural conditions. SFRC, known for its exceptional fire resistance, emerges as a promising alternative to Ordinary Portland Cement (OPC) in elevating concrete properties. The experimental and numerical findings consistently demonstrated a noteworthy 12% increase in maximum loading capacity, exhibiting a consistent curved trend at the moment against mid-span displacement when employing the composite material. Finite Element Analysis (FEA) modeling was used to scrutinize core concrete failure patterns, residual displacements of external metal during the load-carrying process, and load distribution patterns throughout the structural element. The infusion of SFRC into light gauge steel sections was found to enhance load-carrying capacity, ductility, and toughness. This paper scrutinizes the mechanical properties and structural behavior of LGSHS filled with SFRC, encompassing steel and concrete properties, member geometry, and response to fire exposure. The primary objective is to assess the load-deformation characteristics of rectangular hollow beams formed by concrete-filled steel tubes (CFST) filled with SFRC. The investigation aims to determine load-carrying capacity, strain, deformation capacity, ductility, and failure characteristics under ambient and elevated temperatures.