Sergio Kurokawa

Prof. Dr. Sergio Kurokawa

Department of Electrical Engineering, São Paulo State University, Ilha Solteira, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ECEduardo Marques da Costa
Eduardo Marques da Costa
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
An estimation procedure for transmission line parameters is developed that combines a new method of determining line parameters with others available in the technical literature. Each estimation method has certain advantages and restrictions that depend on the operating conditions of the transmission system (e.g. the load profile), the physical characteristics of the line (e.g. the length and the geometry) and electromagnetic phenomena (e.g. single‐ or multiphase faults). The proposed estimation procedure exploits the major attributes of both the new determination method developed in this study and other well‐established methods previously presented in the technical literature. Based on current and voltage measurements obtained from synchronised fault records from both line terminals, a combination of multiple methods can be used to accurately estimate most line parameters, a task that is typically impossible using a single method.

6 September 2010 in IET Generation, Transmission & Distribution
Verified
Journal Article
Closed access
ECEduardo Marques da Costa
Eduardo Marques da Costa
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
JFJosé Pissolato Filho
José Pissolato Filho
APA.J. Prado
A.J. Prado
This paper presents a hybrid way mixing time and frequency domain for transmission lines modelling. The proposed methodology handles steady fundamental signal mixed with fast and slow transients, including impulsive and oscillatory behaviour. A transmission line model is developed based on lumped elements representation and state-space techniques. The proposed methodology represents an easy and practical procedure to model a three-phase transmission line directly in time domain, without the explicit use of inverse transforms. The proposed methodology takes into account the frequency-dependent parameters of the line, considering the soil and skin effects. In order to include this effect in the state matrices, a fitting method is applied. Furthermore the accuracy of proposed the developed model is verified, in frequency domain, by a simple methodology based on line distributed parameters and transfer function related to the input/output signals of the lumped parameters representation. In addition, this article proposes the use of a fast and robust analytic integration procedure to solve the state equations, enabling transient and steady-state simulations. The results are compared with those obtained by the commercial software Microtran (EMTP), taking into account a three-phase transmission line, typical in the Brazilian transmission system.

1 July 2009 in Electric Power Systems Research
Verified
Journal Article
Closed access
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
FYFábio N.R. Yamanaka
Fábio N.R. Yamanaka
APAfonso J. Prado
Afonso J. Prado
JFJosé Pissolato Filho
José Pissolato Filho

1 March 2014 in IET Science, Measurement & Technology
Verified
Journal Article
Open access
PDF file
JMJosé Humberto A. Monteiro
José Humberto A. Monteiro
ECEduardo Marques da Costa
Eduardo Marques da Costa
APAndré Jinno G. Pinto
André Jinno G. Pinto
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
OGOmar Mohamed O. Gatous
Omar Mohamed O. Gatous
JFJosé Pissolato Filho
José Pissolato Filho
This study presents a simplified formulation to calculate the skin effect on transmission lines wires. The methodology is developed from the solution of the time‐domain Maxwell's wave equations whose frequency‐domain solutions are obtained using Fourier transforms. Results obtained from the proposed formulation are compared with those calculated using the conventional method based on the approach by Bessel functions. The proposed skin‐effect formulation is also validated based on electromagnetic transients simulations in the time domain considering a conventional 69‐kV transmission system.

1 November 2017 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
PCPablo Torrez Caballero
Pablo Torrez Caballero
ECEduardo Marques da Costa
Eduardo Marques da Costa
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa

1 April 2014
Verified
Conference Paper
Closed access
Anderson Ricardo Justo de AraújoAnderson Ricardo Justo de Araújo
Anderson Ricardo Justo de Araújo
RSR. C. Silva
R. C. Silva
Sergio KurokawaSergio Kurokawa
Sergio Kurokawa
The solutions of differential equations of transmission line are generally difficult to obtain due to the convolution integral present. Considering this, there are models proposed for the study of electromagnetic transients in transmission line. In this paper a single-phase transmission line is represented by two models. The first model represents the transmission line by its distributed parameters and its differential equations in the time domain are transformed into algebraic equations in the frequency domain. This model is named ULM. Once the solutions were obtained in the frequency domain, using the ILT implemented numerically, the solutions are obtained in the time domain. The second model uses lumped circuits parameters and it considers the transmission line represented by π-circuits connected in cascade. This model has the advantage of being developed directly in the time domain, but there is a need to apply numerical integration methods to solve the equations. A fact observed in the responses using this models is the spurious oscillations. In this paper are shown spurious oscillations presents in simulations and using FT to analyze the spectral content of this oscillations for a single-phase transmission line considering different conditions as its length, represented by different quantities of π-circuit and submitted to diverse conditions of energization.