Seungnam Yu

Dr. Seungnam Yu

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2007 in Automation in Construction
Verified
Journal Article
Closed access
SYSeungnam Yu
Seungnam Yu
JJJae-Ho Jang
Jae-Ho Jang
CHChang-Soo Han
Chang-Soo Han

1 August 2009 in Automation in Construction
Verified
Journal Article
Closed access
SYSeungnam Yu
Seungnam Yu
BRByung-Gab Ryu
Byung-Gab Ryu
SLSung-Jin Lim
Sung-Jin Lim
CKChang-Jun Kim
Chang-Jun Kim
MKMaing-Kyu Kang
Maing-Kyu Kang
CHChang-Soo Han
Chang-Soo Han

27 December 2006 in Autonomous Robots
Verified
Journal Article
Closed access
PDF file
SYSeungnam Yu
Seungnam Yu
SLSeung Yeol Lee
Seung Yeol Lee
CHChang-soo Han
Chang-soo Han
KLKye Young Lee
Kye Young Lee
SLSang Heon Lee
Sang Heon Lee

1 January 2014 in Applied Bionics and Biomechanics
Verified
Journal Article
Open access
PDF file
SYSeungnam Yu
Seungnam Yu
CHChangsoo Han
Changsoo Han
ICIlje Cho
Ilje Cho
This paper describes the development of a wearable exoskeleton system for the lower extremities of infantry soldiers and proposes appropriate design criteria based on existing case studies. Because infantry soldiers carry a variety of equipment, the interference with existing equipment and additional burden of the exoskeleton support system should be minimized. Recent studies have shown that a user only needs to be supported in the gravitational direction when walking on flat terrain; however, active joints are necessary to support walking over rough and sloped terrain such as mountains. Thus, an underactuated exoskeleton system was considered: passive joints are applied to the hip and ankle joints, and active joints are applied to the knee joints to exploit the dynamic coupling effect of the link structure and muscular activation patterns when the user is going up and down stairs. A prototype of the exoskeleton system was developed and validated through a simple stair-climbing experiment.

1 January 2012 in Advanced Robotics
Verified
Journal Article
Closed access
SYS. N. Yu
S. N. Yu
HLH. D. Lee
H. D. Lee
SLS. H. Lee
S. H. Lee
Wansoo KimWansoo Kim
Wansoo Kim
JHJ. S. Han
J. S. Han
SYSeungnam Yu
Seungnam Yu
This study proposes an under-actuated wearable exoskeleton system to carry a heavy load. To synchronize that system with a user, a feasible modular-type wearable system and its corresponding sensor...

16 February 2016 in Advanced Robotics
Verified
Journal Article
Closed access
SYSeungnam Yu
Seungnam Yu
HLHeedon Lee
Heedon Lee
Wansoo KimWansoo Kim
Wansoo Kim
CHChangsoo Han
Changsoo Han
This study proposed and developed an underactuated exoskeleton to support external load-carrying and partial assist for leg motion with level walking and ascending of slopes and stairs, which require positive energy generation. A strategy for active and passive joint combination are implemented on the underactuated exoskeleton, along with a quasi-passive mechanism to assist with vertical weight support and gait propulsion while minimizing hindrance to the wearer’s free motion. Further, muscle circumference sensors are directly matched with the active joint system, and insole sensors are applied to efficiently detect the wearer’s motion intension. Through experiments with the developed exoskeleton system, the considered performances were verified by analyzing the electromyography data from the rectus fremoris and gastrocnemius muscles while walking and ascending stairs. The developed underactuated exoskeleton can assist healthy people’s load-carrying and facilitate efficient ascension by utilizing the structural body weight support, leg swing, and lifting motion assist through motorized knee joints only. This kind of active joint minimization approach could be particularly helpful in field applications that require independent power sources such as batteries.