ٍShady El Naggar

Prof. ٍShady El Naggar

Badr University in Cairo, Cairo, Al Qāhirah, Egypt
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2022 in Journal of The Arab Society for Medical Research
Verified
Journal Article
Closed access
PDF file
ٍShady El NaggarٍShady El Naggar
ٍShady El Naggar
EHEman Helal
Eman Helal
MKMaie F. Khalil
Maie F. Khalil
AEAhmed M. Esmat
Ahmed M. Esmat
AEAsmaa N. Elboraey
Asmaa N. Elboraey
Background/aim: Color stability of complete dentures is one of the most significant aspects that affect the success of complete dentures (CD) and improve the patient’s quality of life. Therefore, the present clinical crossover research targeted to assess and compare the color stability of conventional heat-polymerized polymethyl methacrylate (PMMA) CDs and three-dimensional (3D)-printed dentures and their effect on the ‘oral health-related quality of life’ (OHRQoL). Patients and methods: Twenty completely edentulous patients aged from 45 to 75 received two sets of CDs. The first denture set was polymethyl methacrylate CD (group I), and the patients were instructed to use it for 3 months. Then after 3 months, the patients were instructed to wear the 3D-printed CD set (group II) and use it for another 3 months. The color change of the CD’s base was evaluated at denture insertion after 1 and 3 months using a spectrophotometer. The ‘OHRQoL ’ was used to assess patient satisfaction at the end of the treatment of every denture set. Statistical analysis was accomplished through an independent t test and one-way analysis of variance. Results: Regarding the color change of the CD denture base at denture insertion, there was an insignificant distinction between group I and group II (P>0.05). While after 1 and 3 months, group I showed a significant increase in the color change when compared with group II (P<0.05). When comparing the color change in each group during the different follow-up periods, the color change was significantly increased in both groups (P<0.05). In terms of ‘OHRQoL,’ there was a significant distinction between group I and group II (P<0.05). Group II (18.89) scored less than group I (43.42). Conclusion: 3D-printed CDs exhibit good color stability when compared with conventional CDs. The OHRQoL revealed that 3D-printed CDs have more patient satisfaction than conventional CDs.

4 July 2022 in Journal of The Arab Society for Medical Research
Verified
Journal Article
Open access
ٍShady El NaggarٍShady El Naggar
ٍShady El Naggar
Background/aim Clinical studies comparing the retention values of computer-aided design/ computer-aided manufacturing (CAD/CAM) denture bases with those of conventionally processed denture bases are lacking. The purpose of this clinical study was to compare the retention values of digitally 3D-printed maxillary denture bases with those of conventional heat-polymerized denture bases. Patients and methods The study was conducted on 32 completely edentulous outpatients visiting the clinic of Dental Surgery, Misr University for Science and Technology, Egypt. The patients were divided into two groups, group I received conventional complete dentures (CDs) and group II received 3D-printed CAD/CAM dentures, the retention of the maxillary denture bases was evaluated at the denture insertion and after 1, 3, 6, and 9 months. A universal testing machine was used to measure the retention of each denture. Every denture base was subjected to a slowly increasing vertical load, until the denture was totally out of place three times at 5-minute intervals. The average retention of each denture was analyzed. An independent t-test was performed for significance evaluation between both groups, while one-way analysis of variance followed by Tukey’s post-hoc test was used for multiple comparisons. Results Group II showed a significant increase (P<0.05) in retention in all of the follow-up periods (at the time of denture insertion and after 1, 3, 6, and 9 months) when compared with group I. Definite time intervals of both groups showed a significant difference (P<0.05) in retentive values in all follow-up periods, except for the last two follow-up periods from denture insertion – 6 months and from denture insertion – 9 months showed the insignificant difference in both groups. Conclusion The retention of the maxillary CD prepared with the 3D print CAD/CAM method was significantly higher than conventional heat-polymerized denture bases, meaning that the 3D print CAD/CAM method can meet the clinically acceptable precision for the design and construction of CDs with higher retentive means of completely edentulous patients.

1 October 2021 in Advanced Dental Journal
Verified
Journal Article
Closed access
PDF file
ٍShady El NaggarٍShady El Naggar
ٍShady El Naggar
AEAyman Elawady
Ayman Elawady
ASAhmed Magdy Sayed
Ahmed Magdy Sayed
SESherihan M. Eissa
Sherihan M. Eissa
Objective: Stress analysis and retention evaluation of implant-retained mandibular complete overdenture with different clip materials and distributions. Methods: This in-vitro study was conducted over implants retained mandibular complete overdenture (all-on-4 concept) using BIOHPP bar attachments constructed using 3 D printing with different clip materials and distributions. This study consisted of 4 groups according to the type and distribution of clips: Group I: hard clips anteriorly and posteriorly, Group II: soft clips anteriorly and posteriorly, Group III: hard clips anteriorly and soft clips posteriorly, and Group IV: soft clips anteriorly and hard clips posteriorly. Stress analysis and retention were evaluated before and thermocycling afterward. Results: Comparison between stresses in each group before and after thermocycling in central and peripheral implants was performed, revealing stresses in all groups after thermocycling were significantly higher than before thermocycling as P < 0.05. Regarding retention, a comparison between all groups revealed a significant difference between them before and after thermocycling as P<0.05. Conclusion: There is no effect of clip material distribution regarding stress analysis and retention before and after thermocycling except stresses in central implant before thermocycling as soft clips anteriorly and hard clips posteriorly revealed significant lower stresses than hard clips anteriorly and soft clips posteriorly.

8 November 2018 in Open Access Macedonian Journal of Medical Sciences
Verified
Journal Article
Open access
PDF file
ٍShady El NaggarٍShady El Naggar
ٍShady El Naggar
MNMohamed I. Seif El Nasr
Mohamed I. Seif El Nasr
HSHassan M. Sakr
Hassan M. Sakr
SESherihan M. Eissa
Sherihan M. Eissa
AEAsmaa N. Elboraey
Asmaa N. Elboraey
AMAmani R. Moussa
Amani R. Moussa
BACKGROUND: A gap still exists between in vitro and clinical studies concerning the biocompatibility of the material in the oral environment and their potential to cause immunological undesirable side effects. The uses of glass fibres to improve the mechanical properties of acrylic resin denture base polymers are well documented in vitro. AIM: The present study aimed to evaluate the effect of denture base reinforcement using light-cured E- glass fibres mesh on the level of salivary immunoglobulin A (S-IgA) in patients wearing complete dentures. MATERIAL AND METHODS: Fourteen completely edentulous patients, in need of complete dentures, participated in the study. The patients were divided into two groups (n = 7) according to the treatment protocol. In the first group, patients received conventional heat-cured acrylic resin dentures. In the second group, the mandibular dentures were reinforced using light cured resin impregnated E glass fibres mesh. In both groups, salivary samples were collected using passive drool technique. The level IgA was assessed by enzyme-linked immunosorbent assay (ELISA) technique at different time intervals. Statistical analysis was carried out using one-way ANOVA followed by Tukey`s post-hoc test and independent t-test. The significant level was set at P ≤ 0.05. RESULTS: Acrylic resin dentures and reinforced ones demonstrated an increase in the mean values of IgA level at the end of the follow-up intervals. And this increase was statistically significant (P ≤ 0.05). Although, the reinforced dentures revealed higher mean values, there was no statistically significant difference between the two groups (P > 0.05) CONCLUSIONS: Within the limitations of the present study, the following could be concluded: (1) the insertion of complete dentures induced changes in the level of IgA; and (2) denture base reinforcement using light cured resin impregnated E-glass fibres mesh had a similar effect to that of heat cured acrylic resin on the level of IgA.

4 July 2022 in Journal of The Arab Society for Medical Research
Verified
Journal Article
Open access
ٍShady El NaggarٍShady El Naggar
ٍShady El Naggar
MBMai F.F. Khalil B
Mai F.F. Khalil B
Background/aim Digital Smile Design (DSD) software is a beneficial approach to the potential of patient smile enhancement by producing an esthetic treatment plan. This study aimed to evaluate the precision and accuracy of hand calibrated, photo analysis, and DSD method in removable complete dentures and correlate them with different types of denture teeth. Patients and methods This study was conducted on 29 completely edentulous patients selected from the Outpatient Clinic of Prosthodontic Department, Faculty of Oral and Dental Medicine, Badr University, Egypt. Each patient received two sets of complete dentures as follows: the first denture was constructed from a conventional complete denture with cross-linked resin teeth and served as the control group (group I), and the second denture was constructed from conventional complete denture with nanohybrid composite teeth and served as the test group (group II). Each group was further subdivided into three subgroups, according to the different smile analysis techniques performed: subgroup A, hand calibrated method; subgroup B, photo analysis method, and subgroup C, DSD method. Then, precision and accuracy were evaluated for each smile variable. Results Mean absolute difference was calculated between group I and group II for each smile analysis technique, revealing that the least amount of difference between groups was illustrated in the subgroup A followed by subgroup C and finally subgroup B, which revealed the maximum amount of difference between groups ranged from 0.0031 to 0.2623. Cronbach’s α was calculated for group I and group II between each smile analysis technique, revealing that all was less reliable (less accurate), except lower teeth exposure in group II was rather reliable (rather accurate) ranging from 0.023 to 0.784.Conclusion With the respect to limitations of this study regarding individualized anatomical variations and distortion liability of the image, it was concluded that nanohybrid resin composite denture teeth had less deviation (higher precision) than the conventional acrylic resin denture teeth regarding the ratio of different smile parameters with facial proportions.