Shahriar Mostufa

Mr. Shahriar Mostufa

Rajshahi University of Engineering and Technology, Rājshāhi, Bangladesh
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2023 in Small
Verified
Journal Article
Closed access
BRBahareh Rezaei
Bahareh Rezaei
PYParsa Yari
Parsa Yari
SSSean M. Sanders
Sean M. Sanders
HWHaotong Wang
Haotong Wang
VCVinit K Chugh
Vinit K Chugh
Kai WuKai Wu
Kai Wu

5 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Shahriar MostufaShahriar Mostufa
Shahriar Mostufa
Tarik Bin Abdul AkibTarik Bin Abdul Akib
Tarik Bin Abdul Akib
MRMd. Masud Rana
Md. Masud Rana
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
In this article, a hybrid TiO2/Au/graphene layer-based surface plasmon resonance (SPR) sensor with improved sensitivity and capability for cancer detection is presented. The finite element method (FEM) was used for numerical analysis. The proposed SPR biosensor was structured based on the angular analysis of the attenuated total reflection (ATR) method for the detection of various types of cancer using the refractive index component. The resonance angle shifted owing to the increment of normal and cancerous cells’ refractive index, which varied between 1.36 and 1.401 for six different types of normal and cancerous cells. According to numerical results, the obtained sensitivities for skin (basal), cervical (HeLa), adrenal gland (PC12), blood (Jurkat), and breast (MCF-7 and MDA-MB-231) cancer cells were 210 deg/RIU, 245.83 deg/RIU, 264.285 deg/RIU, 285.71 deg/RIU, 292.86 deg/RIU, and 278.57 deg/RIU, respectively. Furthermore, the detection accuracy (DA), figure of merits (FOM), and signal-to-noise ratio (SNR) were also obtained, with values of 0.263 deg−1, 48.02 RIU−1, and 3.84, respectively. Additionally, the distribution of the electric field and the propagation of the magnetic field for resonant and non-resonant conditions of the proposed structure were illustrated. It was found that an enhanced field was exhibited on the surface of the plasmonic material for resonant conditions. We also measured the penetration depth of 180 nm using decayed electric field intensity. Furthermore, the impact of using a TiO2/Au/graphene layer was demonstrated. We further conducted analyses of the effects of the thickness of the gold layer and the effects of additional graphene layers on overall sensitivities for six different types of cancer. The proposed TiO2/Au/graphene layered structure exhibited the highest overall sensitivity in terms of detecting cancerous cells from healthy cells. Moreover, the proposed sensor was numerically analyzed for a wide range of biological solutions (refractive index 1.33–1.41), and the sensor linearity was calculated with a linear regression coefficient (R2) of 0.9858. Finally, numerical results obtained in this manuscript exhibited high sensitivity in comparison with previously reported studies.

22 July 2021 in OSA Continuum
Verified
Journal Article
Closed access
PDF file
Shahriar MostufaShahriar Mostufa
Shahriar Mostufa
APAlok Kumar Paul
Alok Kumar Paul
KCKisalaya Chakrabarti
Kisalaya Chakrabarti
In this paper, we have presented a design and simulation of a graphene-coated surface plasmon resonance (SPR) based biosensor for targeting specific biological components. We have explicitly shown the detection of the hemoglobin level in blood samples and the glucose concentration level in urine samples by using the finite element method (FEM) based numerical simulation. In the blood component, the 0.001 refractive index increment causes a 6.1025 g/l hemoglobin (HB) level increment, which has been detected using this SPR based sensor with 200 deg/RIU angular sensitivity. Moreover, we have also detected the presence or absence of diabetes using the glucose concentration level in urine samples with this SPR sensor. Therefore, the novelty of this paper is detecting the blood hemoglobin level and glucose concentration levels in urine samples more accurately than the previously proposed whispering gallery mode (WGM) and photonic crystal nanocavity based optical sensors.

30 May 2024 in ACS Omega
Verified
Journal Article
Open access
Shahriar MostufaShahriar Mostufa
Shahriar Mostufa
BRBahareh Rezaei
Bahareh Rezaei
SCStefano Ciannella
Stefano Ciannella
PYParsa Yari
Parsa Yari
JGJenifer Gómez-Pastora
Jenifer Gómez-Pastora
Kai WuKai Wu
Kai Wu
Optical biosensors exhibit immense potential, offering extraordinary possibilities for biosensing due to their high sensitivity, reusability, and ultrafast sensing capabilities. This review provides a concise overview of optical biosensors, encompassing various platforms, operational mechanisms, and underlying physics, and it summarizes recent advancements in the field. Special attention is given to plasmonic biosensors and metasurface-based biosensors, emphasizing their significant performance in bioassays and, thus, their increasing attraction in biosensing research, positioning them as excellent candidates for lab-on-chip and point-of-care devices. For plasmonic biosensors, we emphasize surface plasmon resonance (SPR) and its subcategories, along with localized surface plasmon resonance (LSPR) devices and surface enhance Raman spectroscopy (SERS), highlighting their ability to perform diverse bioassays. Additionally, we discuss recently emerged metasurface-based biosensors. Toward the conclusion of this review, we address current challenges, opportunities, and prospects in optical biosensing. Considering the advancements and advantages presented by optical biosensors, it is foreseeable that they will become a robust and widespread platform for early disease diagnostics.

25 July 2023 in ACS Applied Nano Materials
Verified
Journal Article
Closed access
Shahriar MostufaShahriar Mostufa
Shahriar Mostufa
PYParsa Yari
Parsa Yari
BRBahareh Rezaei
Bahareh Rezaei
KXKanglin Xu
Kanglin Xu
Kai WuKai Wu
Kai Wu

25 March 2023 in Optical and Quantum Electronics
Verified
Journal Article
Open access
PDF file
Tarik Bin Abdul AkibTarik Bin Abdul Akib
Tarik Bin Abdul Akib
Shahriar MostufaShahriar Mostufa
Shahriar Mostufa
Md. Masud RanaMd. Masud Rana
Md. Masud Rana
MHMd. Biplob Hossain
Md. Biplob Hossain
Md. Rabiul IslamMd. Rabiul Islam
Md. Rabiul Islam
This paper presents a performance comparison of heterostructure surface plasmon resonance (SPR) biosensors for the application of Novel Coronavirus SARS-CoV-2 diagnosis. The comparison is performed and compared with the existing literature based on the performance parameters in terms of several prisms such as BaF2, BK7, CaF2, CsF, SF6, and SiO2, several adhesion layers such as TiO2, Chromium, plasmonic metals such as Ag, Au, and two-dimensional (2D) transition metal dichalcogenides materials such as BP, Graphene, PtSe2 MoS2, MoSe2, WS2, WSe2. To study the performance of the heterostructure SPR sensor, the transfer matrix method is applied, and to analyses, the electric field intensity near the graphene-sensing layer contact, the finite-difference time-domain approach is utilized. Numerical results show that the heterostructure comprised of CaF2/TiO2/Ag/BP/Graphene/Sensing-layer has the best sensitivity and detection accuracy. The proposed sensor has an angle shift sensitivity of 390°/refractive index unit (RIU). Furthermore, the sensor achieved a detection accuracy of 0.464, a quality factor of 92.86/RIU, a figure of merit of 87.95, and a combined sensitive factor of 85.28. Furthermore, varied concentrations (0–1000 nM) of biomolecule binding interactions between ligands and analytes have been observed for the prospects of diagnosis of the SARS-CoV-2 virus. Results demonstrate that the proposed sensor is well suited for real-time and label-free detection particularly SARS-CoV-2 virus detection.