Underground mining often causes large-gradient vertical and horizontal displacement in ground surface, resulting in the losses of coherence and difficulties in phase unwrapping. This article presents an approach to determine three-dimensional ground displacements in mining areas with the large gradient or phase decorrelation by integrating multiple interferometric synthetic aperture radar (InSAR) methods. The core of the proposed method is that the offset-tracking method is employed to solve for the displacement with the large gradient or phase decorrelation. First, the displacements in the radar line-of-sight directions are obtained from two interferometric pairs with different viewing geometries by integrating the measurements of differential InSAR and offset tracking. Then, the displacements in the azimuthal directions are obtained from two interferometric pairs with different viewing geometries by integrating the measurements of multiple aperture interferometry and offset tracking. Finally, the three-dimensional ground displacement fields are inferred from these four independent, one-dimensional displacements using the least squares method and Helmert variance component estimation. We apply this method to obtain the three-dimensional ground displacement field in the Dongtan mine region. We compare the results with those of levelling and global positioning system surveys, and the root mean square errors of the results were 24 and 43 mm in the vertical direction and horizontal directions, respectively. The experimental results indicate that the proposed method can be used to estimate three-dimensional ground displacement fields in mining areas with large-gradient displacement and phase decorrelation.
The microseismic signal is easily affected by observation noise and the inaccurate estimation of traditional methods will seriously reduce the location accuracy of the microseismic event. Therefore, based on the continuous wavelet spectrum and the similarity coefficient, a fast and efficient microseismic time delay estimation method is proposed. Firstly, the original signals are denoised by continuous wavelet transform. Subsequently, the time-frequency transform of the original signal by continuous wavelet transform, time-frequency signal extraction is the process of band-pass filtering, which can further reduce the influence of noise interference on the time delay estimation. Finally, we calculated the similarity between the time-frequency signals via the time domain and frequency domain integration. The similarity function is based on correlation and proposed according to the time-frequency transformation provided by the phase spectrum to evaluate the similarity between two noisy signals. The time delay estimation is determined by searching for the similarity function peak. The experimental results show the precision and accuracy of the method over the cross-correlation method and generalized cross-correlation phase transformation method, especially when the signal-to-noise ratio is low. Therefore, a new time delay estimation method for non-stationary random signals is presented in this paper.
To ascertain the 2011 Tohoku-Oki Mw 9.0 earthquake’s impact on the stability of the Yishu fault zone, this study inverts the fault locking degree and slip rate defect distribution of the Yishu fault zone using GPS horizontal velocity field data covering the period from 1999 to 2009 and from April 2011 to 2019. This is based on the block negative dislocation model. Combined with the b value and strain field characteristics, the properties of deformation of the Yishu fault zone before and after the earthquake are comprehensively analyzed. The results show that before the 2011 Tohoku-Oki Mw 9.0 earthquake, the locking degree and depth of the northern segment of the Yishu fault zone were higher, while the locking depth of the southern segment of the fault was shallower. The 2011 Tohoku-Oki earthquake produced different coseismic effects on the southern and northern sections of the Yishu fault zone. The extension on the southern section and compression on the northern section caused the strain release in the southern sections of the Yishu fault zone following the earthquake. After it, the regional locking degree of the southern section of the Yishu fault zone was relieved. However, the locking degree of the northern segment of the fault zone was still high and the depth was deep, at about 26 km. In addition, the northern section of the Yishu fault zone was a section with an abnormally low b value and small earthquakes in the northern segment are sparse at present. The coseismic compression of the northern section caused by the 2011 Tohoku-Oki earthquake is conducive to its locking and easily accumulates stress, so it is necessary to pay attention to its seismic risk.
The ground gravity anomalies can be used to calibrate and validate the satellite gravity gradiometry data. In this study, an upward continuation method of ground gravity data based on spherical harmonic analysis is proposed, which can be applied to the calibration of satellite observations from the European Space Agency's Gravity Field and Steady-State Ocean Circulation Explorer (GOCE). Here, the following process was conducted to apply this method. The accuracy of the upward continuation method based on spherical harmonic analysis was verified using simulated ground gravity anomalies. The DTU13 global gravity anomaly data were used to determine the calibration parameters of the GOCE gravitational gradients based on the spherical harmonic analysis method. The trace and the tensor invariants I2, I3 of the gravitational gradients were used to verify the calibration results. The results revealed that the upward continuation errors based on spherical harmonic analysis were much smaller than the noise level in the measurement bandwidth of the GOCE gravity gradiometer. The scale factors of the Vxx, Vyy, Vzz, and Vyz components were determined at an order of magnitude of approximately 10−2, the Vxz component was approximately 10−3, and the Vxy component was approximately 10−1. The traces of gravitational gradients after calibration were improved when compared with the traces before calibration and were slightly better than the EGG_TRF_2 data released by the European Space Agency (ESA). In addition, the relative errors of the tensor invariants I2, I3 of the gravitational gradients after calibration were significantly better than those before calibration. In conclusion, the upward continuation method based on spherical harmonic analysis could meet the external calibration accuracy requirements of the gradiometer.
The ground gravity anomalies can be used to calibrate and validate the satellite gravity gradiometry data. In this study, an upward continuation method of ground gravity data based on spherical harmonic analysis is proposed, which can be applied to the calibration of satellite observations from the European Space Agency's Gravity Field and Steady-State Ocean Circulation Explorer (GOCE). Here, the following process was conducted to apply this method. The accuracy of the upward continuation method based on spherical harmonic analysis was verified using simulated ground gravity anomalies. The DTU13 global gravity anomaly data were used to determine the calibration parameters of the GOCE gravitational gradients based on the spherical harmonic analysis method. The trace and the tensor invariants I2, I3 of the gravitational gradients were used to verify the calibration results. The results revealed that the upward continuation errors based on spherical harmonic analysis were much smaller than the noise level in the measurement bandwidth of the GOCE gravity gradiometer. The scale factors of the Vxx, Vyy, Vzz, and Vyz components were determined at an order of magnitude of approximately 10−2, the Vxz component was approximately 10−3, and the Vxy component was approximately 10−1. The traces of gravitational gradients after calibration were improved when compared with the traces before calibration and were slightly better than the EGG_TRF_2 data released by the European Space Agency (ESA). In addition, the relative errors of the tensor invariants I2, I3 of the gravitational gradients after calibration were significantly better than those before calibration. In conclusion, the upward continuation method based on spherical harmonic analysis could meet the external calibration accuracy requirements of the gradiometer.
The ground gravity anomalies can be used to calibrate and validate the satellite gravity gradiometry data. In this study, an upward continuation method of ground gravity data based on spherical harmonic analysis is proposed, which can be applied to the calibration of satellite observations from the European Space Agency's Gravity Field and Steady-State Ocean Circulation Explorer (GOCE). Here, the following process was conducted to apply this method. The accuracy of the upward continuation method based on spherical harmonic analysis was verified using simulated ground gravity anomalies. The DTU13 global gravity anomaly data were used to determine the calibration parameters of the GOCE gravitational gradients based on the spherical harmonic analysis method. The trace and the tensor invariants I2, I3 of the gravitational gradients were used to verify the calibration results. The results revealed that the upward continuation errors based on spherical harmonic analysis were much smaller than the noise level in the measurement bandwidth of the GOCE gravity gradiometer. The scale factors of the Vxx, Vyy, Vzz, and Vyz components were determined at an order of magnitude of approximately 10−2, the Vxz component was approximately 10−3, and the Vxy component was approximately 10−1. The traces of gravitational gradients after calibration were improved when compared with the traces before calibration and were slightly better than the EGG_TRF_2 data released by the European Space Agency (ESA). In addition, the relative errors of the tensor invariants I2, I3 of the gravitational gradients after calibration were significantly better than those before calibration. In conclusion, the upward continuation method based on spherical harmonic analysis could meet the external calibration accuracy requirements of the gradiometer.