SHI DONGDONG

Dr. SHI DONGDONG

Yangzhou University, Yangzhou, Jiangsu, China
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in International Journal of Biological Sciences
Verified
Journal Article
Open access
CYChaogang Yang
Chaogang Yang
CWChen Wei
Chen Wei
SWShu-Yi Wang
Shu-Yi Wang
SHsong-hee han
song-hee han
SDSHI DONGDONG
SHI DONGDONG
BXBin Xiong
Bin Xiong
Background: The preoperative controlling nutritional status (CONUT) score and circulating tumour cell (CTC) status are associated with poor prognosis of colorectal cancer (CRC). The aim of the present study is to determine whether the combination of CONUT and CTC (CONUT-CTC) could better predict the prognosis of CRC patients treated with curative resection.

5 August 2019 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SDSHI DONGDONG
SHI DONGDONG
DWDaohong Wang
Daohong Wang
TWTing Wu
Ting Wu
NTNobuyuki Takagi
Nobuyuki Takagi
Using the negative cloud‐to‐ground lightning cases well located by the Fast Antenna Lightning Mapping Array, we have examined the general characteristics of the preliminary breakdown (PB) and stepped leader (SL) processes, and further studied the correlation between the first return stroke (RS1st) intensity and its preceding discharge processes. The RS1st intensity is measured from the range‐normalized radiation field. The parameters used to characterize PB/SL include PB altitude, PB/SL vertical speed, PB/SL pulse rate, and SL duration. The arithmetic mean PB altitude is about 5.6 km and exhibits a weak inverse correlation with the RS1st intensity. As the PB develops into the SL, the arithmetic mean vertical speed decreases from 4.7 × 105 to 1.7 × 105 m/s and the arithmetic mean pulse rate reduces from 5.1 to 2.4 ms−1. In the PB/SL processes, the average vertical speed and pulse rate have positive correlations with the RS1st intensity while the corresponding Spearman's correlation coefficient for SL is considerably larger than that for PB. The average SL duration is 34 ms and has a negative relation to the RS1st intensity, with the coefficient of −0.71. These results demonstrate that on average, lower initiation altitude, faster PB/SL vertical speed, higher PB/SL pulse rate, and shorter SL duration tend to be followed by stronger RS1st. According to the above correlations, we speculate that the combination of a middle negative charge region with a uniform and wide horizontal distribution and a small lower positive charge region is a favorable condition for an intense RS1st.

13 December 2019 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SDSHI DONGDONG
SHI DONGDONG
DWDaohong Wang
Daohong Wang
TWTing Wu
Ting Wu
NTNobuyuki Takagi
Nobuyuki Takagi
We have studied the temporal and spatial characteristics of preliminary breakdown (PB) pulses in 32 normal intracloud flashes recorded by a fast antenna lightning mapping array system called Fast Antenna Lightning Mapping Array. It was found that PB processes started with a stage of preliminary isolated pulses (PIPs) and followed by classic PB pulse (PBP) clusters. A typical PIP stage consists of two or three PIPs and on average lasts about 129 μs. A typical PBP cluster consists of several narrow pulses (NPs) and one classic PBP and on average lasts about 193 μs. During one PIP stage, the pulses occurring later usually have a lower altitude, indicating a kind of backward extension relative to the overall upward progression of PB process. On average, the horizontal and vertical extensions involved in a PIP stage are 60 and 216 m, respectively. In each PBP cluster, PBP is always located at the lowest height and behind its preceding NPs, while these NP locations could have various patterns in term of extension. On average, the overall horizontal and vertical extensions involved in a typical PBP cluster are 161 and 515 m, respectively. For both the PIP stage and PBP cluster, their vertical extensions are apparently longer than their horizontal extensions, reflecting a predominantly vertical channel of PB process. Based on the temporal and spatial characteristics of PB pulses, we have proposed a model to interpret how the PIPs, NPs, and PBPs are produced.

12 September 2018 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SDSHI DONGDONG
SHI DONGDONG
DWDaohong Wang
Daohong Wang
TWTing Wu
Ting Wu
RTRonald J. Thomas
Ronald J. Thomas
HEHarald E. Edens
Harald E. Edens
PKPaul R. Krehbiel
Paul R. Krehbiel
We have analyzed three upward bipolar lightning flashes (UBLFs) that occurred in Japanese winter thunderstorms. Leader polarity‐reversal processes in three flashes share the same features. During the several tens of milliseconds (lightning A 56 ms, lightning B 21 ms, lightning C 67 ms) before the initiation of the polarity‐reversal leader, one branch of the preceding leader in bipolar flashes was nearly decayed while other branches of the preceding leader were still in propagation. Then the polarity‐reversal leader will be initiated at the end of the decayed branch of the preceding leader. Initial sources of the polarity‐reversal leader are characterized by relatively strong very high frequency power (average value in lightning A, B, and C 24, 18, and 14 dBW) and obvious upward progression. Two of the three upward lightning (lightning A and B) occurred at a normal dipolar charge structure, while the remaining one (lightning C) occurred at an inverted dipolar charge structure. Based on the common features of the polarity‐reversal leader and charge structure, we have proposed a scenario to interpret the process of upward bipolar lightning flashes.

16 September 2020 in Journal of Geophysical Research: Atmospheres
Verified
Journal Article
Open access
PDF file
SDSHI DONGDONG
SHI DONGDONG
DWDaohong Wang
Daohong Wang
TWTing Wu
Ting Wu
NTNobuyuki Takagi
Nobuyuki Takagi
We have compared the E‐change pulses occurring in the upper positive charge region (UPCR) and the middle negative charge region (MNCR) of 41 normal intracloud (IC) flashes. E‐change pulses can be roughly grouped into isolated pulses and pulse trains with both positive and negative polarities. Although isolated pulses occurred about equally in UPCR and MNCR, there were much more pulse trains in MNCR than UPCR. Overall, the average amplitude, rise time, half‐peak width, and fall time of isolated pulses (pulse trains) are 56% larger (115% larger), 31% faster (43% slower), 25% narrower (46% wider), and 26% shorter (62% longer) in UPCR than in MNCR. Interestingly, in the same charge region, positive and negative pulses share similar characteristics. Based on a typical well‐structured IC, it was found that the majority of isolated pulses in both UPCR and MNCR occurred at or close to the leader tips. In contrast, about 30% UPCR pulse trains occurred at or close to the tip, while the remaining 70% pulse trains occurred in the leader channel retracing along the leader channel away from the flash origin; for MNCR pulse trains, about 60% occurred close to the tip, and 40% occurred in the channel with a backward extension to the flash origin. Based on these characteristics, we have discussed the physical nature of various types of pulses and pointed out that a leader is likely to progress with a fluctuating behavior when it is neutralizing space charge distributed in a region with sufficient thickness and width.

20 October 2024 in Remote Sensing
Verified
Journal Article
Open access
PDF file
SDSHI DONGDONG
SHI DONGDONG
JZJinlai Zhang
Jinlai Zhang
PGPanliang Gao
Panliang Gao
DZDong Zheng
Dong Zheng
QQQi Qi
Qi Qi
TWTing Wu
Ting Wu
We have studied the parameters of preliminary breakdown (PB) pulses in 395 normal and 319 inverted intracloud (IC) flashes observed in Gifu, Japan, and Ningxia, China, respectively, by using a low-frequency mapping system called fast antenna lightning mapping array (FALMA). These parameters are extracted from the first half of the PB pulses. It is found that compared to normal IC flashes, inverted IC flashes exhibited PB pulses with slower rise times (6.8 vs. 3.1 μs), wider half-peak widths (3.8 vs. 2.5 μs), longer zero-crossing times (26.2 vs. 14 μs), and extended fall times (4 vs. 3.2 μs). We further demonstrated that such discrepancies between normal and inverted IC flashes should not be caused by subjective factors, like noise threshold setting, or objective factors, like signal propagation distance. Based on this analysis, finally, we inferred that the discrepancies should be a reflection of the PB channel properties of normal and inverted IC flashes.