Shin-ichi Miyashita

Dr. Shin-ichi Miyashita

National Institute of Advanced Industrial Science and Technology, Tsukuba, Japan
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2014 in Applied Microbiology and Biotechnology
Verified
Journal Article
Closed access
PDF file
AMAyumi Minoda
Ayumi Minoda
HSHitomi Sawada
Hitomi Sawada
SSSonoe Suzuki
Sonoe Suzuki
SMShin-ichi Miyashita
Shin-ichi Miyashita
KIKazumi Inagaki
Kazumi Inagaki
MTMikio Tsuzuki
Mikio Tsuzuki

1 July 2016 in Bioresource Technology
Verified
Journal Article
Open access
XJXiaohui Ju
Xiaohui Ju
KIKensuke Igarashi
Kensuke Igarashi
SMShin-ichi Miyashita
Shin-ichi Miyashita
HMHiroaki Mitsuhashi
Hiroaki Mitsuhashi
KIKazumi Inagaki
Kazumi Inagaki
AMAyumi Minoda
Ayumi Minoda
The demand for precious metals has increased in recent years. However, low concentrations of precious metals dissolved in wastewater are yet to be recovered because of high operation costs and technical problems. The unicellular red alga, Galdieria sulphuraria, efficiently absorbs precious metals through biosorption. In this study, over 90% of gold and palladium could be selectively recovered from aqua regia-based metal wastewater by using G. sulphuraria. These metals were eluted from the cells into ammonium solutions containing 0.2M ammonium salts without other contaminating metals. The use of G. sulphuraria is an eco-friendly and cost-effective way of recovering low concentrations of gold and palladium discarded in metal wastewater.

20 May 2014 in Journal of Analytical Atomic Spectrometry
Verified
Journal Article
Closed access
PDF file
SMShin-ichi Miyashita
Shin-ichi Miyashita
AGAlexander S. Groombridge
Alexander S. Groombridge
SFShin-Ichiro Fujii
Shin-Ichiro Fujii
AMAyumi Minoda
Ayumi Minoda
ATAkiko Takatsu
Akiko Takatsu
KIKazumi Inagaki
Kazumi Inagaki
To realise highly efficient single-cell analysis of microbial cells by time-resolved inductively coupled plasma mass spectrometry (ICP-MS), we developed a modified high efficiency cell introduction system (HECIS), consisting of a large-bore high performance concentric nebulizer (LB-HPCN) with a centre capillary tube of 150 μm inner diameter and a custom-made small-volume (15 cm3) on-axis spray chamber that uses a sheath gas flow near the chamber exit to suppress cell deposition. We also assembled an external ion pulse counting unit to directly read the ion pulse current from the electron multiplier of the ICP-MS via a function generator with no dead time, in order to obtain data with sufficiently high time resolution (i.e., 0.05–1 ms). As compared to a conventional ICP-MS working at its minimum integration time (10 ms), this assembly led to more than ca. 13-fold higher signal-to-background ratios for 31P, and made higher throughput of cells to the plasma more feasible. By using the modified HECIS and the external ion pulse counting unit for determination of the cell introduction efficiencies of different-sized unicellular microbes, including yeast (Saccharomyces cerevisiae), cyanobacterium (Synechocystis sp. PCC 6803), red algae (Cyanidioschyzon merolae 10D and Galdieria sulphuraria), and green alga (Chlamydomonas reinhardtii CC-125), it was revealed that their cell introduction efficiencies ranged from 86% (for C. reinhardtii CC-125 with a mean cell diameter of 6.4 μm) to ca. 100% (for other microbes with mean cell diameters of 2.0–3.0 μm), implying that by use of the ICP-MS system, the cell introduction efficiencies are able to reach approximately 100% and tend to decrease with increasing cell sizes (at least more than 3.1 μm in mean diameter). A wide range of biologically important elements, such as C, Mg, Al, P, S, K, Ca, Cr, Mn, Fe, and Zn, were tested for reasonable detection using the ICP-MS system. Results likely corresponding to separate cell events were obtained for some elements present in each microbe.

1 May 2009 in Chemosphere
Verified
Journal Article
Closed access
SMShin-ichi Miyashita
Shin-ichi Miyashita
MSMasahito Shimoya
Masahito Shimoya
YKYoshiaki Kamidate
Yoshiaki Kamidate
TKTakayoshi Kuroiwa
Takayoshi Kuroiwa
OSOsamu Shikino
Osamu Shikino
TKToshikazu Kaise
Toshikazu Kaise

10 June 2013 in Analytical Sciences
Verified
Journal Article
Open access
PDF file
AGAlexander S. Groombridge
Alexander S. Groombridge
SMShin-ichi Miyashita
Shin-ichi Miyashita
SFShin-Ichiro Fujii
Shin-Ichiro Fujii
KNKeisuke Nagasawa
Keisuke Nagasawa
TOTetsuya Okahashi
Tetsuya Okahashi
KCKoichi Chiba
Koichi Chiba
Trace elemental analysis of single yeast cells with time-resolved inductively coupled plasma mass spectrometry (ICP-MS) was successfully carried out, where a high efficiency cell introduction system (HECIS) consisting of the high performance concentric nebulizer (HPCN) and a low-volume (15 mL) on-axis spray chamber utilizing a sheath gas flow were used. Cell adsorption to the flow injector and sample tubing was reduced with the addition of a simple 4.3 mmol L−1 of NaCl solution to the cell suspension and cell flowing liquid, allowing consecutive measurements without fear of significant contamination from previous measurements. Initially using a quadrupole mass analyzer ICP-MS (ICP-QMS) at its lowest integration time (10 ms), current spikes corresponding to separate cell events were detected for several elements (Mg, P, Ca, Mn, Fe, Cu, and Zn) on the introduction of the cell suspension. On comparing the number of peaks in the spectrum for phosphorous with the cell count using a haemocytometer, a reproducible cell transport efficiency of 75.0 ± 4.7% was achieved. Preliminary experiments into using time of flight ICP-MS (ICP-TOFMS) for single-cell analysis were carried out, allowing quasi-simultaneous multielement detection. The spectra of Mg, P, Ca, Mn, Fe, Cu, and Zn, with a time resolution of 1 ms were simultaneously obtained in one measurement. A relatively strong correlation was observed for the spectra between P and Zn (correlation factor 0.69), P and Mg (0.63), and Mg and Zn (0.63). These results indicate that the time resolved quasi-simultaneous multielement measurement may be useful for the correlation analysis of multielements in cells.

14 November 2008 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Closed access
PDF file
YYYuta Yoshino
Yuta Yoshino
BYBo Yuan
Bo Yuan
SMShin-ichi Miyashita
Shin-ichi Miyashita
NINoriyoshi Iriyama
Noriyoshi Iriyama
AHAkira Horikoshi
Akira Horikoshi
TKToshikazu Kaise
Toshikazu Kaise