Siddharth Maddali

Dr. Siddharth Maddali

Argonne National Laboratory
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2019 in Optics Express
Verified
Journal Article
Open access
PDF file
SKSaugat Kandel
Saugat Kandel
Siddharth MaddaliSiddharth Maddali
Siddharth Maddali
MAMarc Allain
Marc Allain
SHStephan O. Hruszkewycz
Stephan O. Hruszkewycz
CJChris J Jacobsen
Chris J Jacobsen
YNYoussef Nashed
Youssef Nashed
Coherent diffraction imaging methods enable imaging beyond lens-imposed resolution limits. In these methods, the object can be recovered by minimizing an error metric that quantifies the difference between diffraction patterns as observed, and those calculated from a present guess of the object. Efficient minimization methods require analytical calculation of the derivatives of the error metric, which is not always straightforward. This limits our ability to explore variations of basic imaging approaches. In this paper, we propose to substitute analytical derivative expressions with the automatic differentiation method, whereby we can achieve object reconstruction by specifying only the physics-based experimental forward model. We demonstrate the generality of the proposed method through straightforward object reconstruction for a variety of complex ptychographic experimental models.

1 January 2016 in IUCrJ
Verified
Journal Article
Open access
LRLoïc Renversade
Loïc Renversade
RQRomain Quey
Romain Quey
WLWolfgang Ludwig
Wolfgang Ludwig
DMDavid Menasche
David Menasche
Siddharth MaddaliSiddharth Maddali
Siddharth Maddali
ABAndrás Borbély
András Borbély
The grain structure of an Al–0.3 wt%Mn alloy deformed to 1% strain was reconstructed using diffraction contrast tomography (DCT) and high-energy diffraction microscopy (HEDM). 14 equally spaced HEDM layers were acquired and their exact location within the DCT volume was determined using a generic algorithm minimizing a function of the local disorientations between the two data sets. The microstructures were then compared in terms of the mean crystal orientations and shapes of the grains. The comparison shows that DCT can detect subgrain boundaries with disorientations as low as 1° and that HEDM and DCT grain boundaries are on average 4 µm apart from each other. The results are important for studies targeting the determination of grain volume. For the case of a polycrystal with an average grain size of about 100 µm, a relative deviation of about ≤10% was found between the two techniques.

6 March 2020 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
Siddharth MaddaliSiddharth Maddali
Siddharth Maddali
PLP. Li
P. Li
APA. Pateras
A. Pateras
DTD. Timbie
D. Timbie
NDN. Delegan
N. Delegan
SHS. O. Hruszkewycz
S. O. Hruszkewycz

14 May 2019 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AUA. Ulvestad
A. Ulvestad
SHS. O. Hruszkewycz
S. O. Hruszkewycz
MHM. V. Holt
M. V. Holt
MHM. O. Hill
M. O. Hill
ICI. Calvo-Almazán
I. Calvo-Almazán
MSM. E. Stuckelberger
M. E. Stuckelberger
The factors limiting the performance of alternative polycrystalline solar cells as compared with their single-crystal counterparts are not fully understood, but are thought to originate from structural and chemical heterogeneities at various length scales. Here, it is demonstrated that multimodal focused nanobeam X-ray microscopy can be used to reveal multiple aspects of the problem in a single measurement by mapping chemical makeup, lattice structure and charge collection efficiency simultaneously in a working solar cell. This approach was applied to micrometre-sized individual grains in a Cu(In,Ga)Se2 polycrystalline film packaged in a working device. It was found that, near grain boundaries, collection efficiency is increased, and that in these regions the lattice parameter of the material is expanded. These observations are discussed in terms of possible physical models and future experiments.

6 March 2020 in Journal of Applied Crystallography
Verified
Journal Article
Open access
PDF file
PLP. Li
P. Li
Siddharth MaddaliSiddharth Maddali
Siddharth Maddali
APA. Pateras
A. Pateras
ICI. Calvo-Almazan
I. Calvo-Almazan
SHS.O. Hruszkewycz
S.O. Hruszkewycz
MAM. Allain
M. Allain
X-ray Bragg coherent diffraction imaging (BCDI) has been demonstrated as a powerful 3D microscopy approach for the investigation of sub-micrometre-scale crystalline particles. The approach is based on the measurement of a series of coherent Bragg diffraction intensity patterns that are numerically inverted to retrieve an image of the spatial distribution of the relative phase and amplitude of the Bragg structure factor of the diffracting sample. This 3D information, which is collected through an angular rotation of the sample, is necessarily obtained in a non-orthogonal frame in Fourier space that must be eventually reconciled. To deal with this, the approach currently favored by practitioners (detailed in Part I) is to perform the entire inversion in conjugate non-orthogonal real- and Fourier-space frames, and to transform the 3D sample image into an orthogonal frame as a post-processing step for result analysis. In this article, which is a direct follow-up of Part I, two different transformation strategies are demonstrated, which enable the entire inversion procedure of the measured data set to be performed in an orthogonal frame. The new approaches described here build mathematical and numerical frameworks that apply to the cases of evenly and non-evenly sampled data along the direction of sample rotation (i.e. the rocking curve). The value of these methods is that they rely on the experimental geometry, and they incorporate significantly more information about that geometry into the design of the phase-retrieval Fourier transformation than the strategy presented in Part I. Two important outcomes are (1) that the resulting sample image is correctly interpreted in a shear-free frame and (2) physically realistic constraints of BCDI phase retrieval that are difficult to implement with current methods are easily incorporated. Computing scripts are also given to aid readers in the implementation of the proposed formalisms.

8 October 2019 in IEEE Journal of Photovoltaics
Verified
Journal Article
Closed access
Irene Calvo-AlmazanIrene Calvo-Almazan
Irene Calvo-Almazan
XHXiaojing Huang
Xiaojing Huang
HYHanfei Yan
Hanfei Yan
ENEvgeny Nazaretski
Evgeny Nazaretski
YCYong S. Chu
Yong S. Chu
MBMariana I. Bertoni
Mariana I. Bertoni
Strain within grains and at grain boundaries (GBs) in polycrystalline thin-film absorber layers limits the overall performance because of higher defect concentrations and band fluctuations. However, the nanoscale strain distribution in operational devices is not easily accessible using standard methods. X-ray nanodiffraction offers the unique possibility to evaluate the strain or lattice spacing at nanoscale resolution. Furthermore, the combination of nanodiffraction with additional techniques in the framework of multimodal scanning X-ray microscopy enables the direct correlation of the strain with material and device parameters such as the elemental distribution or local performance. This approach is applied for the investigation of the strain distribution in CdTe grains in fully operational photovoltaic solar cells. It is found that the lattice spacing in the (111) direction remains fairly constant in the grain cores but systematically decreases at the GBs. The lower strain at GBs is accompanied by an increase of the total tilt. These observations are both compatible with the inhomogeneous incorporation of smaller atoms into the lattice, and local stress induced by neighboring grains.