Sourin Bhattacharya

Mr. Sourin Bhattacharya

Transport Department, Government of West Bengal, Kolkata, India
+1
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


5 January 2023 in World Journal of Engineering
Verified
Journal Article
Closed access
Sourin BhattacharyaSourin Bhattacharya
Sourin Bhattacharya
SMSanjib Majumder
Sanjib Majumder
SRSubarna Roy
Subarna Roy
Purpose: Properly planned road illumination systems are collectively a public wealth and the commissioning of such systems may require extensive planning, simulation and testing. The purpose of this simulative work is to offer a simple approach to facilitate luminance-based road lighting calculations that can be easier to comprehend and apply to practical designing problems when compared to complex multi-objective algorithms and other convoluted simulative techniques. Design/methodology/approach: Road illumination systems were photometrically simulated with a created model in a validated software platform for specified system design configurations involving high-pressure sodium (HPS) and light-emitting diode (LED) luminaires. Multiple regression analyses were conducted with the simulatively obtained data set to propound a linear model of estimating average luminance, overall uniformity of luminance and energy efficiency of lighting installations, and the simulatively obtained data set was used to explore luminaire power–road surface average luminance characteristics for common geometric design configurations involving HPS and LED luminaires, and four categories of road surfaces. Findings: The six linear equations of the propounded linear model were found to be well-fitted with their corresponding observation sets. Moreover, it was found that the luminaire power–road surface average luminance characteristics were well-fitted with linear trendlines and the increment in road surface average luminance level per watt increment of luminaire power was marginally higher for LEDs. Originality/value: This neoteric approach of estimating road surface luminance parameters and energy efficiency of lighting installations, and the compendia of luminaire power–road surface average luminance characteristics offer new insights that can prove to be very useful for practical purposes.


5 March 2021 in International Journal of Sustainable Energy
Verified
Journal Article
Closed access
Sourin BhattacharyaSourin Bhattacharya
Sourin Bhattacharya
SMSudipta Majumder
Sudipta Majumder
SRSubarna Roy
Subarna Roy
ISImran Hossain Sardar
Imran Hossain Sardar
This work estimated the daylight availability and luminous efficacy of solar illuminance and approximated indoor daylight levels for various indoor daylighting methods for Kolkata, a major city in eastern India having tropical savanna climate, by applying two computational methods: the Perez model and the IESNA recommended calculation procedure. It was found that hourly horizontal diffuse and global illuminance, horizontal sky and total daylight illuminance values remained mostly over 10 klx throughout the year, and global and diffuse luminous efficacies mostly remained around 95–120 and 110–150 lm/W, respectively. The linear correlation between solar irradiation and estimated illuminance was stronger for Perez model. Thus, the application of Perez model was considered the better choice to appraise the daylighting potential of Kolkata.

7 January 2021 in Journal of Engineering, Design and Technology
Verified
Journal Article
Closed access
SRSubarna Roy
Subarna Roy
SMSudipta Majumder
Sudipta Majumder
Sourin BhattacharyaSourin Bhattacharya
Sourin Bhattacharya
ISImran Hossain Sardar
Imran Hossain Sardar
Purpose: An indoor office space should not only provide adequate illuminance on horizontal planes but also cater to the physiological and psychological requirements of the occupants. This paper aims to describe a lighting simulation-based work conducted in Kolkata, India which modeled an indoor office to investigate the effects of variation in room surface reflectance combinations on user perception, mean room surface exitance (MRSE), average horizontal illuminance and overall uniformity of horizontal illuminance. Design/methodology/approach: A fluorescent illumination system–based office space was modeled and retrofitted with tubular LED lamps in DIALux. Simulations were conducted for 16 different room surface reflectance combinations and a five-point Likert scale-type survey questionnaire was formulated to conduct a survey with 32 test subjects to assess the subjective preferability of each resultant light scene. Findings: Simulation results demonstrate that the relationship between average horizontal illuminance and MRSE as well as between average horizontal illuminance and overall uniformity of horizontal illuminance, was statistically significant (p < 0.001). In the conducted survey, the resultant light scene arising out of the reflectance combination of wall:ceiling:floor = 60%:90%:20% was the most well-received one with 187 convinced agreements (“agree” and “strongly agree” responses). Originality/value: This work found strong linear correlation between average horizontal illuminance and MRSE and between average horizontal illuminance and overall uniformity. A five-point Likert scale-type survey questionnaire with seven questions was formulated and validated with 32 test subjects (Cronbach’s alpha > 0.9295), which showed that the wall:ceiling:floor reflectance combination of 60%:90%:20% was the most favored choice.